1.DESCRIPTION OF CODE REGISTRATION
When adding master keys or sub-keys (additional registration).
Register key code in the transponder key ECU assembly.
| Target ECU | See Procedure |
|---|---|
| Transponder key ECU assembly | Procedure "A" |
After replacing the transponder key ECU assembly (New key code registration).
Register the key code (immobiliser code) in the new transponder key ECU assembly.
| Target ECU | See Procedure |
|---|---|
| Transponder key ECU assembly | Procedure "B" |
Register the ECU - ECM COMMUNICATION ID between the ECM and the new transponder key ECU assembly.
| Target ECU | See Procedure |
|---|---|
| ECM | Procedure "C" |
After replacing the ECM.
Reregister the ECU - ECM COMMUNICATION ID between the new ECM and the transponder key ECU assembly.
| Target ECU | See Procedure |
|---|---|
| Transponder key ECU assembly | Procedure "C" |
After replacing the transponder key ECU assembly and ECM.
Register the ECU - ECM COMMUNICATION ID between the new ECM and the new transponder key ECU assembly.
| Target ECU | See Procedure |
|---|---|
| Transponder key ECU assembly | Procedure "C" |
Erasure of key codes.
Erase all of the key codes except master key.
| Target ECU | See Procedure |
|---|---|
| Transponder key ECU assembly | Procedure "D" |
Erase all of the key codes.
| Target ECU | See Procedure |
|---|---|
| Transponder key ECU assembly | Procedure "D" |
2.NEW KEY REGISTRATION (PROCEDURE "B")
New key code registration
This mode operates normally when no key codes are registered in the transponder key ECU assembly.
When a new transponder key ECU assembly is installed, key codes must be registered in the transponder key ECU assembly.
In this mode, a maximum of 3 key codes for 2 master keys and 1 sub-key can be registered. The master keys and sub-key can be registered in any order because the transponder key ECU assembly can distinguish between different types of keys.
New key codes must be registered with the battery connected. The ignition switch can be either ON or OFF.
When using Techstream
| Procedure | Security Indicator Light Condition |
|---|---|
| 1. Start registration. | Security indicator light is blinking. |
| 2. Insert one of master keys into the ignition key cylinder. | Security indicator light is blinking. |
| 3. Select following items on the Techstream:
(1) Body Electrical (2) Immobiliser (3) Utility (4) Key Registration
|
Security indicator light turned off for 1 second and then turned on. |
| 4. Remove the key and then select Next on the Techstream. | Security indicator light turned on. |
| 5. Insert the master key to be registered and then select Next on the Techstream. | Security indicator light turned off for 1 second and then turned on. |
| 6. Remove the key and then select Next on the Techstream. | Security indicator light turned on. |
| 7. Insert the sub-key to be registered and then select Next on the Techstream. | Security indicator light turned off for 1 second and then turned on for 0.5 seconds and then turned off. |
| 8. Remove the key. | Security indicator light is blinking. |
| 9. End of registration. | |
End the new key code registration mode (when using Techstream)
The automatic key code registration mode can be forced to end when at least 1 key code (immobiliser code) for a master key has been registered.
Insert the key into the ignition key cylinder and turn the Techstream ON.
Follow the instructions on the Techstream screen to end the new key code registration mode.
When the engine immobiliser system is operating normally and the key is pulled out, the security indicator light blinks continuously.
If the new key code registration fails, code 2-1 is output by the security indicator light. Trying to reregister an already registered key causes code 2-2 to be output when the key is inserted. If the number of registered key codes exceeds the limit, code 2-3 is output by the security indicator light.
3. REGISTRATION OF ADDITIONAL KEY (PROCEDURE "A")
Additional key code registration
At least one key code must be registered in the transponder key ECU assembly in order for this mode to operate normally.
In this mode, a maximum of 5 master key codes and 3 sub-key codes can be registered.
This mode ends if each step is not completed within the specified time.
When the ignition key cylinder or the ignition key cylinder set is replaced, remove the transmitter module from the original master key. Then install this transmitter module to a new key and use the new key as the master key. If necessary, use this master key to register other keys.
When only the ignition key cylinder has been replaced, the new key cannot be used to lock or unlock doors. Therefore, keep the original key for locking and unlocking doors in order to avoid being locked out of the vehicle if the transmitter battery becomes depleted.
When using Techstream
| Procedure | Security Indicator Light Condition | Time (Completion of Operation) |
|---|---|---|
| 1. Start registration. | Security indicator light is blinking. | - |
| 2. Insert an already registered master key into the ignition key cylinder, turn the ignition switch to ON, and turn the Techstream ON. | Security indicator light turned off. | Within 120 seconds |
| 3. Select following items on the Techstream:
(1) Body Electrical (2) Immobiliser (3) Utility (4) Key Registration |
Security indicator light turned on. | |
| 4. Remove the master key and then push NEXT button on the Techstream. | Security indicator light turned on. | Within 20 seconds of the instruction on the Techstream. |
| 5. Insert unregistered key into the ignition key cylinder. | Security indicator light is blinking.
|
Within 10 seconds |
6. After 60 seconds, key is registered.
|
Security indicator light turned off. | - |
| 7. Remove the key. | Security indicator light is blinking. | |
| 8. Techstream screen displays number of registered keys. | ||
| 9. Register another key ?
YES: Go to step 2. NO: Go to step 10. |
||
| 10. End of registration. | ||
A brief outline of the procedures for key code registration is shown above. For more detailed information, refer to the screen of the Techstream.
When the engine immobiliser system is operating normally and the key is pulled out, the security indicator light blinks continuously.
If the additional key code registration fails, code 2-1 is output by the security indicator light. Trying to reregister a previously registered key causes code 2-2 to be output when the key is inserted. If the number of registered key codes exceeds the limit, code 2-3 is output by the security indicator light. The output details are shown in procedure "B".
4. ERASURE OF KEY CODE (PROCEDURE "D")
All key codes are erased except for the master key which is used for erasing the key codes. In order to use a key whose code has been erased, a new key code must be registered.
Erasure all key codes except master key
In this mode, a maximum of 5 master key codes and 3 sub-key codes can be registered.
Make sure the inserted key is a registered master key.
At least one key code must be registered in the transponder key ECU assembly in order for this mode to operate normally.
When using Techstream
| Procedure | Security Indicator Light Condition | Time (Completion of Operation) |
|---|---|---|
| 1. Start of erasure. | Security indicator light is blinking. | - |
| 2. Insert previously registered master key into ignition key cylinder and turn ignition switch to ON. | Security indicator light turned off. | Within 120 seconds |
| 3. Select following items on the Techstream:
(1) Body Electrical (2) Immobiliser (3) Utility (4) Transponder Code Erasure |
Security indicator light turned on for 1 second then turned off. | |
4. Remove the master key.
|
Security indicator light is blinking. | Within 10 seconds of the instruction on the Techstream. |
| 5. End of erasure. | ||
Erasure all of key codes
This mode performs normally, when at least one key codes must be registered in the transponder key ECU assembly.
Insertion key is either registered key or unregistered key.
When using Techstream
| Procedure | Security Indicator Light Condition | Time (Completion of Operation) |
|---|---|---|
| 1. Start of erasure. | Security indicator light is blinking. | - |
| 2. Insert previously registered master key or unregistered key into ignition key cylinder and turn ignition switch to ON. | Security indicator light turned on or off. | Within 10 minutes |
| 3. Using TIS, confirm that user and vehicle match. | ||
| 4. Select following items on the Techstream:
(1) Body Electrical (2) Immobiliser (3) Utility (4) Immobiliser Code Reset |
Security indicator light turned on for 1 second then turned off. | Within 15 minutes |
| 5. Completion of erasure of all key codes is displayed. | Security indicator light turned on. | - |
| 6. End of erasure. | ||
A brief outline of the procedures for key code registration is shown above. For more detailed information, refer to the screen of the Techstream.
When the engine immobiliser system is operating normally and the key is pulled out, the security indicator light blinks continuously.
5.ECU - ECM COMMUNICATION ID REGISTRATION (PROCEDURE "C")
The ECU - ECM communication ID must be registered to the transponder key ECU assembly and ECM when one of the following occurs in order to match their IDs: 1) the transponder key ECU assembly is replaced, 2) the ECM is replaced, or 3) the transponder key ECU assembly and ECM are replaced.
The SFI system cannot be started unless the ECU - ECM communication IDs of the transponder key ECU assembly and ECM match.
After replacing the transponder key ECU assembly
Register the key code(s) by following the new key code registration procedure (procedure "B").
Using SST, connect terminals 13 (TC) and 4 (CG) of the DLC3 before inserting the key into the key cylinder.
| Procedure | Security Indicator Light Condition |
|---|---|
1. Insert previously registered key into ignition key cylinder and turn ignition switch to ON.
|
Security indicator light turned off. |
| 2. Leave vehicle as is for 30 minutes. | |
| 3. Turn the ignition switch off and disconnect terminals TC and CG. | |
| 4. Start engine. | |
| 5. Check that engine starts and stays on for more than 3 seconds Registration is complete. |
After replacing the ECM
Register the ECU - ECM communication ID.
| Procedure | Security Indicator Light Condition |
|---|---|
| 1. Insert previously registered key into ignition key cylinder. | Security indicator light turned off. |
| 2. Start engine. | |
| 3. Check that engine starts and stays on for more than 3 seconds Registration is complete. |
After replacing the transponder key ECU assembly and ECM
Register the key code(s) by following the new key code registration procedure (procedure "B").
Register the ECU - ECM communication ID.
| Procedure | Security Indicator Light Condition |
|---|---|
| 1. Insert previously registered key into ignition key cylinder. | Security indicator light turned off. |
| 2. Start engine. | |
| 3. Check that engine starts and stays on for more than 3 seconds Registration is complete. |