Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM
RM27L0U _58 Vehicle Interior _049344 HEATING / AIR CONDITIONING _0235901 AIR CONDITIONING SYSTEM C

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM  B1419/19  Rear Room Temperature Sensor Circuit  


DESCRIPTION

The cooler (duct sensor) thermistor (rear room temperature sensor) is installed in the rear panel to detect the rear room temperature and control the heater and air conditioner AUTO mode. The resistance of the cooler (duct sensor) thermistor (rear room temperature sensor) changes in accordance with the rear room temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.

The air conditioning amplifier applies a voltage (5 V) to the cooler (duct sensor) thermistor (rear room temperature sensor) and reads voltage changes as changes in the resistance of the cooler (duct sensor) thermistor (rear room temperature sensor).

DTC Code DTC Detection Condition Trouble Area
B1419/19 Open or short in rear room temperature sensor circuit
·

Cooler (duct sensor) thermistor (rear room temperature sensor)

·

Harness or connector between cooler (duct sensor) thermistor (rear room temperature sensor) and air conditioning amplifier

·

Air conditioning amplifier



WIRING DIAGRAM

E345196E01
0.604,2.573 1.063,2.771 0.458,0.198 10 false O15 0.604,2.76 2.688,3.333 2.083,0.573 10 false Cooler (Duct Sensor) Thermistor (Rear Room Temperature Sensor) 5.031,2.583 5.49,2.781 0.458,0.198 10 false H67 5.021,2.781 6.656,3.094 1.635,0.313 10 false Air Conditioning Amplifier 2.438,1.01 2.594,1.208 0.156,0.198 10 false 1 2.448,1.865 2.604,2.063 0.156,0.198 10 false 2 4.583,1 4.896,1.198 0.313,0.198 10 false 17 4.635,1.865 4.906,2.063 0.271,0.198 10 false 7 4.948,1.115 5.26,1.313 0.313,0.198 10 false TR 4.958,1.969 5.469,2.156 0.51,0.188 10 false SG-6

PROCEDURE

1.READ VALUE USING TECHSTREAM (ROOM TEMP SENSOR (REAR))
a.

Connect the Techstream to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the Techstream on.


d.

Enter the following menus: Body Electrical / Air Conditioner / Data List / Rear Temp Sensor (Rear).


e.

According to the display on the Techstream, read the Data List.

Air Conditioner
Tester Display Measurement Item/Range Normal Condition Diagnostic Note
Room Temp Sensor (Rear) Room temperature sensor /
Min.: -6.5°C (20.3°F)
Max.: 57.25°C (135.05°F)
Actual rear room temperature is displayed Open circuit: -6.5°C (20.3°F)
Short circuit: 57.25°C (135.05°F)

OK:

The display is as specified in the normal condition.


Result
Result Proceed to
NG A
OK (When troubleshooting according to Problem Symptoms Table) B
OK (When troubleshooting according to the DTC output) C



A

2.INSPECT COOLER (DUCT SENSOR) THERMISTOR (REAR ROOM TEMPERATURE SENSOR)

B

PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE

C

2.INSPECT COOLER (DUCT SENSOR) THERMISTOR (REAR ROOM TEMPERATURE SENSOR)
a.

Remove the cooler (duct sensor) thermistor (rear room temperature sensor) (See page Vehicle Interior>HEATING / AIR CONDITIONING>ROOM TEMPERATURE SENSOR(for Rear Side)>REMOVAL).

E345197E01
0.479,0.271 2.917,0.823 2.438,0.552 10 false Component without harness connected: (Cooler (Duct Sensor) Thermistor) 4.052,0.271 6.344,0.469 2.292,0.198 10 false Resistance (kΩ) 4.667,3.104 6.094,3.51 1.427,0.406 10 false Temperature (°C) 5.469,3.323 6.083,3.521 0.615,0.198 10 false (°F)


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 10°C (50°F) 3.00 to 3.73 kΩ
15°C (59°F) 2.45 to 2.88 kΩ
20°C (68°F) 1.95 to 2.30 kΩ
25°C (77°F) 1.60 to 1.80 kΩ
30°C (86°F) 1.28 to 1.47 kΩ
35°C (95°F) 1.00 to 1.22 kΩ
40°C (104°F) 0.80 to 1.00 kΩ
45°C (113°F) 0.65 to 0.85 kΩ
50°C (122°F) 0.50 to 0.70 kΩ
55°C (131°F) 0.44 to 0.60 kΩ
60°C (140°F) 0.36 to 0.50 kΩ


HINT:
·

Touching the sensor even slightly may change the resistance value. Be sure to hold the connector of the sensor.

·

When measuring, the sensor temperature must be the same as the ambient temperature.

·

As the temperature increases, the resistance decreases (see the graph).




c.

Reinstall the cooler (duct sensor) thermistor (rear room temperature sensor).



OK

3.CHECK HARNESS AND CONNECTOR (REAR ROOM TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER)

NG

REPLACE COOLER (DUCT SENSOR) THERMISTOR (REAR ROOM TEMPERATURE SENSOR)

3.CHECK HARNESS AND CONNECTOR (REAR ROOM TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER)
a.

Disconnect the O15 cooler (duct sensor) thermistor (rear room temperature sensor) connector.

E345198E01
0.667,1.396 1.063,1.656 0.396,0.26 3.188,1.021 3.594,1.26 0.406,0.24 4.063,2.396 4.385,2 true 4.792,2.385 4.5,2.063 true 0.646,0.104 3.031,0.771 2.385,0.667 10 false Front view of wire harness connector: (to Cooler (Duct Sensor)Thermistor (Rear Room Temperature Sensor)) 0.75,1.438 1.208,1.635 0.458,0.198 10 false O15 4.104,0.135 6.365,0.771 2.26,0.635 10 false Rear view of wire harness connector: (to Air Conditioning Amplifier) 3.281,1.063 3.74,1.26 0.458,0.198 10 false H67 3.938,2.406 4.552,2.604 0.615,0.198 10 false SG-6 4.833,2.354 5.448,2.552 0.615,0.198 10 false TR


b.

Disconnect the H67 air conditioning amplifier connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
O15-1 - H67-17 (TR) Always Below 1 Ω
O15-2 - H67-7 (SG-6) Always Below 1 Ω
O15-1 or H67-17 (TR) - Body ground Always 10 kΩ or higher
O15-2 or H67-7 (SG-6) - Body ground Always 10 kΩ or higher



d.

Reconnect the air conditioning amplifier connector.


e.

Reconnect the cooler (duct sensor) thermistor (rear room temperature sensor) connector.



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR