Home › ENGINE › 2GR-FE ENGINE CONTROL SYSTEM › SFI SYSTEM

DTC    P0010    Camshaft Position "A" Actuator Circuit (Bank 1)

DTC    P0020    Camshaft Position "A" Actuator Circuit (Bank 2)

for Preparation Click here


DESCRIPTION

The Variable Valve Timing (VVT) system includes the ECM, Oil Control Valve (OCV) and VVT controller. The ECM sends a target duty-cycle control signal to the OCV. This control signal regulates the oil pressure supplied to the VVT controller. Camshaft timing control is performed according to engine operating conditions such as intake air volume, throttle valve position and engine coolant temperature. The ECM controls the OCV, based on the signals transmitted by several sensors. The VVT controller regulates the intake camshaft angle using oil pressure through the OCV. As a result, the relative positions of the camshaft and crankshaft are optimized, the engine torque and fuel economy improves, and the exhaust emissions decrease under overall driving conditions. The ECM detects the actual intake valve timing using signals from the camshaft and crankshaft position sensors, and performs feedback control. This is how the target intake valve timing is verified by the ECM.

A103843E02


DTC No.
DTC Detection Condition
Trouble Area
P0010
Open or short in OCV for intake camshaft (bank 1) circuit
(1 trip detection logic)
  1. Open or short in OCV for intake camshaft (bank 1) circuit
  2. OCV for intake camshaft (bank 1)
  3. ECM
P0020
Open or short in OCV for intake camshaft (bank 2) circuit
(1 trip detection logic)
  1. Open or short in OCV for intake camshaft (bank 2) circuit
  2. OCV for intake camshaft (bank 2)
  3. ECM

MONITOR DESCRIPTION

After the ECM sends the "target" duty-cycle signal to the OCV, the ECM monitors the OCV current to establish an "actual" duty-cycle. The ECM detects a malfunction and sets a DTC when the actual duty-cycle ratio varies from the target duty-cycle ratio.

MONITOR STRATEGY


Related DTCs
P0010: VVT OCV (bank 1) range check
P0020: VVT OCV (bank 2) range check
Required sensors / components (Main)
VVT OCV (Variable Valve Timing oil control valve)
Required sensors / components (Sub)
-
Frequency of operation
Continuous
Duration
1 second
MIL operation
Immediately
Sequence of operation
None

TYPICAL ENABLING CONDITIONS


The monitor will run whenever these DTCs are not present
None
All of the following conditions are met:
-
Starter
OFF
Ignition switch
ON
Time after turning ignition switch off to on
0.5 seconds or more

TYPICAL MALFUNCTION THRESHOLDS


One of the following conditions is met:
Condition A, B or C
A. All of the following conditions are met:
-
Battery voltage
11 to 13 V
Target duty ratio
Less than 70 %
Output signal duty ratio
100 % or more
B. All of the following conditions are met:
-
Battery voltage
13 V or more
Target duty ratio
Less than 80 %
Output signal duty ratio
100 % or more
C. All of the following conditions are met:
-
Current cut status
Not cut
Output signal duty ratio
3 % or less

COMPONENT OPERATING RANGE


VVT OCV duty ratio
More than 3 %, and Less than 100 %

WIRING DIAGRAM


A133849E05


INSPECTION PROCEDURE

HINT:
  1. If DTC P0010 is displayed, check the intake camshaft circuit for the right bank VVT system.
  2. Bank 1 refers to the bank that includes cylinder No. 1.
  3. If DTC P0020 is displayed, check the intake camshaft circuit for the left bank VVT system.
  4. Bank 2 refers to the bank that does not include cylinder No. 1.
  5. Read freeze frame data using the Techstream. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can be helpful in determining whether the vehicle was running or stopped, whether the engine was warmed up or not, whether the air-fuel ratio was lean or rich, as well as other data recorded at the time of a malfunction.

1.PERFORM ACTIVE TEST USING CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY (OCV)
  1. Connect the Techstream to the DLC3.

  1. Start the engine and turn the tester on.

  1. Warm up the engine.

  1. On the tester, enter the following menus: Powertrain / Engine and ECT / Active Test / Control the VVT System (Bank 1) or Control the VVT System (Bank 2).

  1. Check the engine speed while operating the Oil Control Valve (OCV) using the tester.

    OK:

    Tester Operation
    Specified Condition
    OCV OFF
    Normal engine speed
    OCV ON
    Engine idles roughly or stalls (soon after OCV switched from OFF to ON)



OK
CHECK FOR INTERMITTENT PROBLEMS (Click here)
NG


2.INSPECT CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY


    A095415E03
  1. Disconnect the C23 or C24 camshaft timing oil control valve (OCV) connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    6.9 to 7.9 Ω

  1. Reconnect the OCV connector.



NG
REPLACE CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY (Click here)
OK


3.CHECK HARNESS AND CONNECTOR (OCV - ECM)


    A162359E01
  1. Disconnect the C23 or C24 camshaft timing oil control valve (OCV) connector.

  1. Disconnect the E11 ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance (Check for open):
    Tester Connection
    Specified Condition
    OC1+ (E11-17) - C23-1
    Below 1 Ω
    OC1- (E11-16) - C23-2
    Below 1 Ω
    OC2+ (E11-15) - C24-1
    Below 1 Ω
    OC2- (E11-14) - C24-2
    Below 1 Ω

    Standard resistance (Check for short):
    Tester Connection
    Specified Condition
    OC1+ (E11-17) or C23-1 - Body ground
    10 kΩ or higher
    OC1- (E11-16) or C23-2 - Body ground
    10 kΩ or higher
    OC2+ (E11-15) or C24-1 - Body ground
    10 kΩ or higher
    OC2- (E11-14) or C24-2 - Body ground
    10 kΩ or higher

  1. Reconnect the OCV connector.

  1. Reconnect the ECM connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (OCV - ECM)
OK

REPLACE ECM (Click here)