Home › ENGINE › 2GR-FE ENGINE CONTROL SYSTEM › SFI SYSTEM

DTC    P0351    Ignition Coil "A" Primary / Secondary Circuit

DTC    P0352    Ignition Coil "B" Primary / Secondary Circuit

DTC    P0353    Ignition Coil "C" Primary / Secondary Circuit

DTC    P0354    Ignition Coil "D" Primary / Secondary Circuit

DTC    P0355    Ignition Coil "E" Primary / Secondary Circuit

DTC    P0356    Ignition Coil "F" Primary / Secondary Circuit

for Preparation Click here

HINT:
  1. These DTCs indicate malfunctions relating to the primary circuit.
  2. If DTC P0351 is set, check the No. 1 ignition coil with igniter circuit.
  3. If DTC P0352 is set, check the No. 2 ignition coil with igniter circuit.
  4. If DTC P0353 is set, check the No. 3 ignition coil with igniter circuit.
  5. If DTC P0354 is set, check the No. 4 ignition coil with igniter circuit.
  6. If DTC P0355 is set, check the No. 5 ignition coil with igniter circuit.
  7. If DTC P0356 is set, check the No. 6 ignition coil with igniter circuit.


DESCRIPTION

A Direct Ignition System (DIS) is used on this vehicle.
The DIS is a 1-cylinder ignition system in which each cylinder is ignited by one ignition coil and one spark plug is connected to the end of each secondary wiring. High-voltage is generated in the secondary wiring and then applied directly to each spark plug. The sparks of the spark plugs pass from the center electrodes to the ground electrodes.
The ECM determines the ignition timing and transmits the ignition (IGT) signals to each cylinder. Using the IGT signal, the ECM turns the power transistor inside the igniter on and off. The power transistor, in turn, switches on and off the current to the primary coil. When the current to the primary coil is cut off, high- voltage is generated in the secondary coil. This voltage is applied to the spark plugs, causing them to spark inside the cylinders. As the ECM cuts the current to the primary coil off, the igniter sends back an ignition confirmation (IGF) signal to the ECM, for each cylinder ignition.

A133853E05


DTC No.
DTC Detection Condition
Trouble Area
P0351
P0352
P0353
P0354
P0355
P0356
No IGF signal to ECM while engine is running (1 trip detection logic)
  1. Ignition system
  2. Open or short in IGF1 or IGT circuit (1 to 6) between ignition coil with igniter and ECM
  3. No. 1 to No. 6 ignition coils with igniters
  4. ECM
Reference: Inspection using an oscilloscope
A140712E01
While cranking or idling, check the waveform between terminals IGT (1 to 6) and E1, and IGF1 and E1 of the ECM connector.
Item
Content
Terminals
CH1: IGT1, IGT2, IGT3, IGT4, IGT5, IGT6 - E1
CH2: IGF1 - E1
Equipment Settings
2 V/Division, 20 ms./Division
Conditions
Cranking or idling

MONITOR DESCRIPTION


A082388E23

If the ECM does not receive any IGF signals despite transmitting the IGT signal, it interprets this as a fault in the igniter and sets a DTC.
If the malfunction is not repaired successfully, a DTC is set 1 second after the engine is next started.

MONITOR STRATEGY


Related DTCs
P0351: Igniter (Cylinder 1) malfunction
P0352: Igniter (Cylinder 2) malfunction
P0353: Igniter (Cylinder 3) malfunction
P0354: Igniter (Cylinder 4) malfunction
P0355: Igniter (Cylinder 5) malfunction
P0356: Igniter (Cylinder 6) malfunction
Required Sensors / Components (Main)
Igniter (Cylinder 1 to 6)
Required Sensors / Components (Related)
Crankshaft position sensor
Frequency of Operation
Continuous
Duration
0.256 seconds and 5 sparks
MIL Operation
Immediate
Sequence of Operation
None

TYPICAL ENABLING CONDITIONS


The monitor will run whenever these DTCs are not present
None
Either of the following conditions is met
Condition 1 or 2
1. All of the following conditions are met:
Condition (a) and (b)
(a) Engine RPM
500 rpm or less
(b) Battery voltage
6 V or more
2. All of the following conditions are met:
Condition (c) and (d)
(c) Engine RPM
More than 500 rpm
(d) Battery voltage
10 V or more

TYPICAL MALFUNCTION THRESHOLDS


Ignition signal fail count
More than 2 times
Ignition signal fail count is on the right
No ignition confirmation signal from igniter.

COMPONENT OPERATING RANGE


IGF signal
Igniter transmits IGF signal when it receives IGT signal from ECM

WIRING DIAGRAM


A140713E07


A140714E02


INSPECTION PROCEDURE

HINT:
Read freeze frame data using the Techstream. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can be helpful in determining whether the vehicle was running or stopped, whether the engine was warmed up or not, whether the air-fuel ratio was lean or rich, as well as other data recorded at the time of a malfunction.

1.CHECK FOR SPARKS AND CHECK SPARK PLUG OF MISFIRING CYLINDER

HINT:



NG
Go to step 4
OK


2.CHECK HARNESS AND CONNECTOR (IGNITION COIL ASSEMBLY - ECM (IGF1 SIGNAL TERMINAL))


    A114622E15
  1. Disconnect the I1, I2, I3, I4, I5 or I6 ignition coil with igniter connector.

  1. Disconnect the E9 ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Check for open:
    Tester Connection
    Specified Condition
    IGF (I1-2) - IGF1 (E9-24)
    Below 1 Ω
    IGF (I2-2) - IGF1 (E9-24)
    Below 1 Ω
    IGF (I3-2) - IGF1 (E9-24)
    Below 1 Ω
    IGF (I4-2) - IGF1 (E9-24)
    Below 1 Ω
    IGF (I5-2) - IGF1 (E9-24)
    Below 1 Ω
    IGF (I6-2) - IGF1 (E9-24)
    Below 1 Ω
    Check for short:
    Tester Connection
    Specified Condition
    IGF (I1-2) or IGF1 (E9-24) - Body ground
    10 kΩ or higher
    IGF (I2-2) or IGF1 (E9-24) - Body ground
    10 kΩ or higher
    IGF (I3-2) or IGF1 (E9-24) - Body ground
    10 kΩ or higher
    IGF (I4-2) or IGF1 (E9-24) - Body ground
    10 kΩ or higher
    IGF (I5-2) or IGF1 (E9-24) - Body ground
    10 kΩ or higher
    IGF (I6-2) or IGF1 (E9-24) - Body ground
    10 kΩ or higher

  1. Reconnect the ECM connector.

  1. Reconnect the ignition coil with igniter connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (IGNITION COIL ASSEMBLY - ECM)
OK


3.INSPECT ECM (IGF1 VOLTAGE)


    A162489E05
  1. Disconnect the I1, I2, I3, I4, I5 or I6 ignition coil with igniter connector.

  1. Turn the ignition switch to the ON position.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Specified Condition
    IGF1 (E9-24) - E1 (E11-1)
    4.5 to 5.5 V

  1. Reconnect the ignition coil connector.



NG
REPLACE ECM (Click here)
OK

REPLACE IGNITION COIL ASSEMBLY (Click here)  

4.CHECK HARNESS AND CONNECTOR (IGNITION COIL ASSEMBLY - ECM (IGT SIGNAL TERMINAL))


    A114622E16
  1. Disconnect the I1, I2, I3, I4, I5 or I6 ignition coil with igniter connector.

  1. Disconnect the E9 ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance :
    Check for open:
    Tester Connection
    Specified Condition
    IGT (I1-3) - IGT1 (E9-8)
    Below 1 Ω
    IGT (I2-3) - IGT2 (E9-9)
    Below 1 Ω
    IGT (I3-3) - IGT3 (E9-10)
    Below 1 Ω
    IGT (I4-3) - IGT4 (E9-11)
    Below 1 Ω
    IGT (I5-3) - IGT5 (E9-12)
    Below 1 Ω
    IGT (I6-3) - IGT6 (E9-13)
    Below 1 Ω
    Check for short:
    Tester Connection
    Specified Condition
    IGT (I1-3) or IGT1 (E9-8) - Body ground
    10 kΩ or higher
    IGT (I2-3) or IGT2 (E9-9) - Body ground
    10 kΩ or higher
    IGT (I3-3) or IGT3 (E9-10) - Body ground
    10 kΩ or higher
    IGT (I4-3) or IGT4 (E9-11) - Body ground
    10 kΩ or higher
    IGT (I5-3) or IGT5 (E9-12) - Body ground
    10 kΩ or higher
    IGT (I6-3) or IGT6 (E9-13) - Body ground
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (IGNITION COIL ASSEMBLY - ECM)
OK


5.INSPECT ECM (IGT1, IGT2, IGT3, IGT4, IGT5 OR IGT6 VOLTAGE)


    A162489E06
  1. Turn the ignition switch to the ON position.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Specified Condition
    IGT1 (E9-8) - E1 (E11-1)
    0.1 to 4.5 V
    IGT2 (E9-9) - E1 (E11-1)
    0.1 to 4.5 V
    IGT3 (E9-10) - E1 (E11-1)
    0.1 to 4.5 V
    IGT4 (E9-11) - E1 (E11-1)
    0.1 to 4.5 V
    IGT5 (E9-12) - E1 (E11-1)
    0.1 to 4.5 V
    IGT6 (E9-13) - E1 (E11-1)
    0.1 to 4.5 V



NG
REPLACE ECM (Click here)
OK


6.INSPECT ECM (IGT1, IGT2, IGT3, IGT4, IGT5 OR IGT6 VOLTAGE)


    A114623E07
  1. Disconnect the I1, I2, I3, I4, I5 or I6 ignition coil connector.

  1. Turn the ignition switch to the ON position.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Specified Condition
    IGT1 (E9-8) - E1 (E11-1)
    4.5 V or more
    IGT2 (E9-9) - E1 (E11-1)
    4.5 V or more
    IGT3 (E9-10) - E1 (E11-1)
    4.5 V or more
    IGT4 (E9-11) - E1 (E11-1)
    4.5 V or more
    IGT5 (E9-12) - E1 (E11-1)
    4.5 V or more
    IGT6 (E9-13) - E1 (E11-1)
    4.5 V or more

  1. Reconnect the ignition coil connector.



NG
REPLACE ECM (Click here)
OK


7.INSPECT IGNITION COIL ASSEMBLY (POWER SOURCE)


    A182664E01
  1. Disconnect the I1, I2, I3, I4, I5 or I6 ignition coil with igniter connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Check for open:
    Tester Connection
    Specified Condition
    GND (I1-4) - Body ground
    Below 1 Ω
    GND (I2-4) - Body ground
    Below 1 Ω
    GND (I3-4) - Body ground
    Below 1 Ω
    GND (I4-4) - Body ground
    Below 1 Ω
    GND (I5-4) - Body ground
    Below 1 Ω
    GND (I6-4) - Body ground
    Below 1 Ω

  1. Turn the ignition switch to the ON position.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Specified Condition
    +B (I1-1) - GND (I1-4)
    9 to 14 V
    +B (I2-1) - GND (I2-4)
    9 to 14 V
    +B (I3-1) - GND (I3-4)
    9 to 14 V
    +B (I4-1) - GND (I4-4)
    9 to 14 V
    +B (I5-1) - GND (I5-4)
    9 to 14 V
    +B (I6-1) - GND (I6-4)
    9 to 14 V

  1. Reconnect the ignition coil with igniter connector.



NG
Go to step 8
OK

REPLACE IGNITION COIL ASSEMBLY (Click here)  

8.INSPECT RELAY (IG2 RELAY)


    B016200
  1. Remove the IG2 relay from the No. 3 engine room R/B.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Specified Condition
    3 - 5
    10 kΩ or higher
    3 - 5
    Bellow 1 Ω
    (when battery voltage applied to terminals 1 and 2)

  1. Reinstall the IG2 relay.



NG
REPLACE RELAY (IG2 RELAY)
OK

REPAIR OR REPLACE HARNESS OR CONNECTOR (IGNITION COIL ASSEMBLY - IGNITION SWITCH)