Home › ENGINE › 2GR-FE ENGINE CONTROL SYSTEM › SFI SYSTEM

DTC    P0116    Engine Coolant Temperature Circuit Range / Performance Problem

for Preparation Click here


DESCRIPTION

Refer to DTC P0115 .

DTC No.
DTC Detection Condition
Trouble Area
P0116
When either of following conditions met (2 trip detection logic):
  1. When cold engine started and engine warmed up, Engine Coolant Temperature (ECT) sensor value does not change.
  2. After warmed up engine started, ECT sensor value does not change when engine stopped and then next cold engine start performed.
  1. Thermostat
  2. ECT sensor
P0116
For Mexico Models:
Case 1:
Engine Coolant Temperature (ECT) between 35°C and 60°C (95°F and 140°F) when engine started, and conditions (a) and (b) met (2 trip detection logic)
  1. (a) Vehicle driven at varying speeds (accelerated and decelerated)
  2. (b) ECT remains within 3°C (37.4°F) of initial ECT
Case 2:
ECT more than 60°C (140°F) when engine started, and conditions (a) and (b) met (6 trip detection logic)
  1. (a) Vehicle driven at varying speeds (accelerated and decelerated)
  2. (b) ECT measurements remain within 1°C (33.8°F) of initial ECT on 6 successive occasions
  1. Thermostat
  2. ECT sensor

MONITOR DESCRIPTION

The ECT sensor is used to monitor the ECT. The ECT sensor has a built-in thermistor with a resistance that varies according to the temperature of the engine coolant. When the ECT becomes low, the resistance of the thermistor increases. When the temperature becomes high, the resistance drops. These variations in the resistance are reflected in the voltage output from the ECT sensor.
The ECM monitors the sensor voltage and uses this value to calculate the ECT. If the sensor voltage output deviates from the normal operating range, the ECM interprets this deviation as a malfunction in the ECT sensor and sets the DTC.
Examples:
  1. Upon starting the engine, the ECT is between 35°C and 60°C (95°F and 140°F). If the ECT remains within 3°C (37.4°F) of the stating temperature after driving for 250 seconds, the DTC is set (2 trip detection logic).
  2. Upon starting the engine, the ECT is over 60°C (140°F). If the ECT remains within 1°C (33.8°F) of the starting temperature after driving for 250 seconds, the DTC is set (6 trip detection logic).
  1. ECT sensor high side stuck monitor (only for Mexico models)
    The ECM monitors the sensor voltage and uses this value to calculate the ECT. If the sensor voltage output deviates from the normal operating range, the ECM interprets this deviation as a malfunction in the ECT sensor and sets the DTC.
    Examples:
    1. Upon starting the engine, the ECT is between 35°C and 60°C (95°F and 140°F). If after driving for 250 seconds, the ECT remains within 3°C (37.4°F) of the starting temperature, the DTC is set (2 trip detection logic).
    2. Upon starting the engine, the ECT is over 60°C (140°F). If after driving for 250 seconds, the ECM remains within 1°C (33.8°F) of the starting temperature, the DTC is set (6 trip detection logic).

MONITOR STRATEGY


Related DTCs
P0116: Engine coolant temperature sensor output stuck
Required Sensors / Components (Main)
Engine Coolant Temperature (ECT) sensor
Required Sensors / Components (Related)
Crankshaft position sensor, intake air temperature sensor and mass air flow meter
Frequency of Operation
Once per driving cycle
Duration
5 hours
MIL Operation
2 driving cycles
Sequence of Operation
None

TYPICAL ENABLING CONDITIONS


All: 
Monitor will run whenever these DTCs are not present.
None

ECT sensor cold start monitor: 
Battery voltage
10.5 V or more
Time after engine start
1 second or more
ECT at engine start
Less than 60°C (140°F)
IAT sensor circuit
OK
Soak time
0 second or more
Accumulated MAF
1966 g or more
Engine
Running
Fuel cut
OFF
Difference between ECT at engine start and IAT
Less than 40°C (104°F)

ECT sensor soak monitor: 
Battery voltage
10.5 V or more
Engine
Running
Soak time
5 hours or more
ECT at engine start
60°C (140°F) or more
Accumulated MAF
3767 g or more

TYPICAL MALFUNCTION THRESHOLDS


ECT sensor cold start monitor: 
ECT sensor value change
Less than 5°C (41°F)

ECT sensor soak monitor: 
ECT sensor value change
Less than 5°C (41°F)

COMPONENT OPERATING RANGE


Engine coolant temperature
Varies with actual engine coolant temperature

INSPECTION PROCEDURE

HINT:
  1. If any of DTC P0115, P0117, P0118 or P0125 are set simultaneously with DTC P0116, the ECT sensor may have an open or a short circuit. Troubleshoot those DTCs first.
  2. Read freeze frame data using the Techstream. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can be helpful in determining whether the vehicle was running or stopped, whether the engine was warmed up or not, whether the air-fuel ratio was lean or rich, as well as other data recorded at the time of a malfunction.

1.CHECK ANY OTHER DTCS OUTPUT (IN ADDITION TO DTC P0166)
  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch to the ON position.

  1. Turn the tester on.

  1. Enter the following menus: Powertrain / Engine and ECT / Trouble Code.

  1. Read the DTC.

    Result:

    Display (DTC output)
    Proceed to
    P0116
    A
    P0116 and other DTCs
    B

HINT:
If any DTCs other than P0116 are output, troubleshoot those DTCs first.



B
GO TO DTC CHART
A


2.INSPECT THERMOSTAT
  1. Remove the thermostat (Click here).

  1. Check the valve opening temperature of the thermostat.

    Standard:
    80 to 84°C (176 to 183°F)

    HINT:
    In addition to the above check, confirm that the valve is completely closed when the temperature is below the standard.

  1. Reinstall the thermostat (Click here).



NG
REPLACE THERMOSTAT
OK

REPLACE ENGINE COOLANT TEMPERATURE SENSOR