Home › ENGINE › 2GR-FE ENGINE CONTROL SYSTEM › SFI SYSTEM

DTC    P2420    Evaporative Emission System Switching Valve Control Circuit High

for Preparation Click here


DTC SUMMARY


DTC No.
Monitoring Item
DTC Detection Condition
Trouble Area
Detection Timing
Detection Logic
P2420
Vent valve stuck open (vent)
The following condition is met during key-off EVAP monitor
  1. EVAP pressure change when vent valve is closed (ON) less than 2.3 mmHg
  1. Pump module (0.02 inch orifice, vacuum pump, vent valve)
  2. Connector / wire harness (Pump module - ECM)
  3. ECM
Ignition switch off
2 trip

DESCRIPTION

The circuit description can be found in the EVAP (Evaporative Emission) System (Click here).

INSPECTION PROCEDURE

Refer to the EVAP System (Click here).

MONITOR DESCRIPTION

5 hours*1 after the ignition switch is turned off, the electric vacuum pump creates negative pressure (vacuum) in the EVAP (Evaporative Emission) system. The ECM monitors for leaks and actuator malfunctions based on the EVAP pressure.

HINT:
*1: If the engine coolant temperature is not below 35°C (95°F) 5 hours after the ignition switch is turned off, the monitor check starts 2 hours later. If it is still not below 35°C (95°F) 7 hours after the ignition switch is turned off, the monitor check starts 2.5 hours later.

Sequence
Operation
Description
Duration
-
ECM activation
Activated by soak timer, 5 hours (7 or 9.5 hours) after ignition switch is turned off.
-
A
Atmospheric pressure measurement
Vent valve turned is OFF (vent) and EVAP system pressure is measured by ECM in order to register atmospheric pressure.
If pressure in EVAP system is not between 70 kPa and 110 kPa (525 mmHg and 825 mmHg), ECM cancels EVAP system monitor.
10 seconds
B
First 0.02 inch leak pressure measurement
In order to determine 0.02 inch leak pressure standard, vacuum pump creates negative pressure (vacuum) through 0.02 inch orifice and then ECM checks if vacuum pump and vent valve operate normally.
60 seconds
C
EVAP system pressure measurement
Vent valve is turned ON (closed) to shut EVAP system.
Negative pressure (vacuum) is created in EVAP system, and then EVAP system pressure is measured. Write down measured value as they will be used in leak check.
If EVAP pressure does not stabilize within 15 minutes, ECM cancels EVAP system monitor.
15 minutes*2
D
Purge VSV monitor
Purge VSV is opened and then EVAP system pressure is measured by ECM.
Large increase indicates normal.
10 seconds
E
Second 0.02 inch leak pressure measurement
After second 0.02 inch leak pressure measurement, leak check is performed by comparing first and second 0.02 inch leak pressure standards.
If stabilized system pressure is higher than second 0.02 inch leak pressure standard, ECM determines that there is a leak in EVAP system.
60 seconds
F
Final check
Atmospheric pressure is measured and then monitoring result is recorded by ECM.
-
*2: If only a small amount of fuel is in the fuel tank, it takes longer for the EVAP pressure to stabilize.


A096746E35

The vent valve turns ON (closes) and the EVAP (Evaporative Emission) system pressure is then measured by the ECM, using the pressure sensor, to conduct an EVAP leak check. If the pressure does not increase when the vent valve is open, the ECM interprets this as the vent valve being stuck open. The ECM illuminates the MIL and sets the DTC.

G036780E11


MONITOR STRATEGY


Required Sensors/Components
Purge VSV and canister pump module
Frequency of Operation
Once per driving cycle
Duration
Within 2 minutes (varies with amount of fuel in tank)
MIL Operation
2 driving cycles
Sequence of Operation
None

TYPICAL ENABLING CONDITIONS


Monitor runs whenever following DTCs are not present
None
EVAP key-off monitor runs when all of following conditions are met
-
Atmospheric pressure
70 to 110 kPa (525 to 825 mmHg)
Battery voltage
10.5 V or more
Vehicle speed
Below 2.5 mph (4 km/h)
Ignition switch
OFF
Time after key off
5, 7 or 9.5 hours
Canister pressure sensor malfunction (P0450, P0452 and P0453)
Not detected
Purge VSV
Not operated by scan tool
Vent valve
Not operated by scan tool
Leak detection pump
Not operated by scan tool
Both of following conditions are met before key off
Conditions 1 and 2
1. Duration that vehicle driven
5 minutes or more
2. EVAP purge operation
Performed
Engine coolant temperature
4.4 to 35°C (40 to 95°F)
Intake air temperature
4.4 to 35°C (40 to 95°F)

TYPICAL MALFUNCTION THRESHOLDS


EVAP pressure change after EVAP canister vent valve ON
Less than 0.3 kPa (2.25 mmHg)

MONITOR RESULT

Refer to CHECKING MONITOR STATUS (Click here).