Home › ENGINE › 2GR-FE ENGINE CONTROL SYSTEM › SFI SYSTEM

SFI SYSTEM > EVAP System

for Preparation Click here


RELATED DTCS


DTC
Monitoring Item
See procedure
P043E
0.02 inch orifice clogged (built into pump module)
Click here
P043F
0.02 inch orifice high-flow (built into pump module)
P0441
  1. Purge VSV (Vacuum Switching Valve) stuck closed
  2. Purge VSV stuck open
  3. Purge flow
Click here
P0450
Pressure sensor (built into pump module) voltage abnormal fluctuation
Click here
P0451
  1. Pressure sensor (built into pump module) noise
  2. Pressure sensor (built into pump module) signal becomes fixed/flat
P0452
Pressure sensor (built into pump module) voltage low
P0453
Pressure sensor (built into pump module) voltage high
P0455
EVAP gross leak
Click here
P0456
EVAP small leak
P2401
Vacuum pump stuck OFF (built into pump module)
Click here
P2402
Vacuum pump stuck ON (built into pump module)
P2419
Vent valve stuck ON (closed) (built into pump module)
P2420
Vent valve stuck OFF (vent) (built into pump module)
Click here
P2610
Soak timer (built into ECM)
Click here
If any EVAP system DTCs are set, the malfunctioning area can be determined using the table below.

A106731E15

NOTICE:
If the 0.02 inch reference pressure difference between the first and second checks is greater than the specification, the DTCs corresponding to the reference pressure (P043E, P043F, P0441, P0455, P0456, P2401, P2420) will be all stored.


CONFIRMATION DRIVING PATTERN

HINT:
After a repair, check Monitor Status by performing the Key-Off Monitor Confirmation and Purge Flow Monitor Confirmation described below.


KEY-OFF MONITOR CONFIRMATION
  1. Preconditions
    The monitor will not run unless:

    1. The vehicle has been driven for 10 minutes or more (in a city area or on a freeway)

    2. The fuel tank is less than 90% full

    3. The altitude is less than 8000 ft (2400 m)

    4. The Engine Coolant Temperature (ECT) is between 4.4°C and 35°C (40°F and 95°F)

    5. The Intake Air Temperature (IAT) is between 4.4°C and 35°C (40°F and 95°F)

    6. The vehicle remains stationary (the vehicle speed is 0 mph [0 km/h])

  2. Monitor Conditions

    1. Allow the engine to idle for at least 5 minutes.

    2. Turn the ignition switch off and wait for 6 hours (8 or 10.5 hours).

      HINT:
      Do not start the engine until checking Monitor Status. If the engine is started, the steps described above must be repeated.

  3. Monitor Status

    1. Connect the Techstream to the DLC3.

    2. Turn the ignition switch to the ON position and turn the tester on.

    3. Select the following menu items: Powertrain / Engine and ECT / Monitor / Evaporative System.

    4. Check the "Monitor Status" displayed on the tester.

      HINT:
      If Incomplete is displayed, the monitor is not completed. Make sure that the preconditions have been met, and perform "Monitor Conditions" again.


PURGE FLOW MONITOR CONFIRMATION (P0441)

HINT:
Perform this monitor confirmation after the Key-Off Monitor Confirmation shows Complete.

  1. Preconditions
    The monitor will not run unless:

    1. The vehicle has been driven for 10 minutes or more (in a city area or on a freeway)
    2. The ECT is between 4.4°C and 35°C (40°F and 95°F)
    3. The IAT is between 4.4°C and 35°C (40°F and 95°F)

  2. Monitor Conditions

    1. Release the pressure from the fuel tank by removing and reinstalling the fuel tank cap.

    2. Warm the engine up until the ECT reaches more than 75°C (167°F).

    3. Increase the engine speed to 3000 rpm once.

    4. Allow the engine to idle and turn the A/C ON for 1 minute.

  3. Monitor Status

    1. Turn the ignition switch off.

    2. Connect the Techstream to the DLC3.

    3. Turn the ignition switch to the ON position and turn the tester on.

    4. Select the following menu items: Powertrain / Engine and ECT / Monitor.

    5. Check the "Monitor Status" displayed on the tester.

      HINT:
      If Incomplete is displayed, the monitor is not completed. Make sure that the preconditions have been met, and perform "Monitor Conditions" again.


MONITOR RESULT

  1. Refer to Checking Monitor Status for detailed information (Click here).
  2. The test value and test limit information are described as shown in the following table. This information is included in Monitor Result of the emissions-related DTC sections:
    1. MID (Monitor Identification Data) is assigned to each emissions-related component.
    2. TID (Test Identification Data) is assigned to each test value.

    3. Scaling is used to calculate the test value indicated on generic OBD II scan tools.

      Thermostat 
      MID
      TID
      Scaling
      Description of Test Value
      Minimum Test Limit
      Maximum Test Limit
      $3D
      $C9
      Multiply by 0.01 [kPa]
      Test value for small leak (P0456)
      Refer to pressure D*
      Minimum test limit for small leak
      Maximum test limit for small leak
      $3D
      $CA
      Multiply by 0.01 [kPa]
      Test value for gross leak (P0455)
      Refer to pressure E*
      Minimum test limit for gross leak
      Maximum test limit for gross leak
      $3D
      $CB
      Multiply by 0.01 [kPa]
      Test value for vacuum pump stuck OFF (P2401)
      Refer to pressure A*
      Minimum test limit for vacuum pump stuck OFF
      Maximum test limit for vacuum pump stuck OFF
      $3D
      $CD
      Multiply by 0.01 [kPa]
      Test value for vacuum pump stuck ON (P2402)
      Refer to pressure A*
      Minimum test limit for vacuum pump stuck ON
      Maximum test limit for vacuum pump stuck ON
      $3D
      $CE
      Multiply by 0.01 [kPa]
      Test value for vent valve stuck OFF (vent) (P2420)
      Refer to pressure C*
      Minimum test limit for vent valve stuck ON
      Maximum test limit for vent valve stuck ON
      $3D
      $CF
      Multiply by 0.01 [kPa]
      Test value for vent valve stuck ON (P2419)
      Refer to pressure A*
      Minimum test limit for vent valve stuck OFF
      Maximum test limit for vent valve stuck OFF
      $3D
      $D0
      Multiply by 0.01 [kPa]
      Test value for 0.02 inch orifice low flow (P043E)
      Refer to pressure B*
      Minimum test limit for 0.02 inch orifice low flow
      Maximum test limit for 0.02 inch orifice low flow
      $3D
      $D1
      Multiply by 0.01 [kPa]
      Test value for 0.02 inch orifice high flow (P043F)
      Refer to pressure A*
      Minimum test limit for 0.02 inch orifice high flow
      Maximum test limit for 0.02 inch orifice high flow
      $3D
      $D4
      Multiply by 0.01 [kPa]
      Test value for purge VSV stuck closed (P0441)
      Refer to pressure F*
      Minimum test limit for purge VSV stuck closed
      Maximum test limit for purge VSV stuck closed
      $3D
      $D5
      Multiply by 0.01 [kPa]
      Test value for purge VSV stuck open (P0441)
      Refer to pressure E*
      Minimum test limit for purge VSV stuck open
      Maximum test limit for purge VSV stuck open
      $3D
      $D7
      Multiply by 0.01 [kPa]
      Test value for purge flow (P0441)
      Refer to pressure G*
      Minimum test limit for purge flow
      Maximum test limit for purge flow
      * Pressures A to G are indicated as shown in the diagram below.


      G038136E05


DESCRIPTION


A163539E01


A126270E01

While the engine is running, if a predetermined condition (closed-loop, etc.) is met, the purge VSV is opened by the ECM and fuel vapors stored in the canister are purged to the intake manifold. The ECM changes the duty cycle ratio of the purge VSV to control purge flow volume.
The purge flow volume is also determined by the intake manifold pressure. Atmospheric pressure is allowed into the canister through the vent valve to ensure that the purge flow is maintained when negative pressure (vacuum) is applied to the canister.
The following two monitors run to confirm appropriate EVAP system operation.

Key-off monitor
This monitor checks for EVAP (Evaporative Emission) system leaks and pump module malfunctions. The monitor starts 5 hours* after the ignition switch is turned off. More than 5 hours are required to allow the fuel to cool down to stabilize the Fuel Tank Pressure (FTP), thus making the EVAP system monitor more accurate.
The electric vacuum pump creates negative pressure (vacuum) in the EVAP system, and the pressure is measured. Finally, the ECM monitors for leaks from the EVAP system and malfunctions in both the pump module and purge VSV, based on the EVAP pressure.

HINT:
*: If the engine coolant temperature is not below 35°C (95°F) 5 hours after the ignition switch is turned off, the monitor check starts 2 hours later. If it is still not below 35°C (95°F) 7 hours after the ignition switch is turned off, the monitor check starts 2.5 hours later.


Purge flow monitor
The purge flow monitor consists of the two monitors. The 1st monitor is always conducted every time and the 2nd monitor is activated if necessary.
  1. The 1st monitor
    While the engine is running and the purge VSV (Vacuum Switching Valve) is ON (open), the ECM monitors the purge flow by measuring the EVAP pressure change. If negative pressure is not created, the ECM begins the 2nd monitor.
  2. The 2nd monitor
    The vent valve is turned OFF (open) and the EVAP pressure is then measured. If the variation in the pressure is less than 0.5 kPa (3.75 mmHg), the ECM interprets this as the purge VSV being stuck closed, and illuminates the MIL and sets DTC P0441 (2 trip detection logic).
  1. Atmospheric pressure check:
    1. In order to ensure reliable malfunction detection, the variation between the atmospheric pressures, before and after conduction of the purge flow monitor, is measured by the ECM.

A126271E05


Component
Operation
Canister
Contains activated charcoal to absorb EVAP (Evaporative Emissions) generated in fuel tank.
Cut-off valve
Located in fuel tank. Valve floats and closes when fuel tank is 100% full.
Purge VSV (Vacuum Switching Valve)
Opens or closes line between canister and intake manifold. ECM uses purge VSV to control EVAP purge flow. In order to discharge EVAP absorbed by canister to intake manifold, ECM opens purge VSV. EVAP discharge volume to intake manifold is controlled by purge VSV duty cycle ratio (current-carrying time). (Open: ON, Close: OFF)
Refueling valve
Controls EVAP pressure from fuel tank to canister. Valve consists of diaphragm, spring and restrictor (diameter: 0.08 inch). When fuel vapor and pressure inside fuel tank increase, valve opens. While EVAP is purged, valve closes and restrictor prevents a large amount of vacuum from affecting pressure in fuel tank. Valve is opened while refueling. When valve is open, adding fuel into fuel tank is possible.
Roll-over valve
Located in fuel tank. Valve closes by its own weight when vehicle overturns to prevent fuel from spilling out.
Service port
Used for connecting vacuum gauge for inspecting EVAP system.
Soak timer
Built into ECM. To ensure accurate EVAP monitor, measures 5 hours (+/- 15 min.) after ignition switch is turned off. This allows fuel to cool down, stabilizing Fuel Tank Pressure (FTP). When approx. 5 hours elapsed, ECM activates.
Canister pump module
Consists of (a) to (d) below. Pump module cannot be disassembled.
(a) Vent valve
Vents and closes EVAP system. When ECM turns valve ON, EVAP system is closed. When ECM turns valve OFF, EVAP system is vented. Negative pressure (vacuum) is created in EVAP system to check for EVAP leaks by closing purge VSV and vent valve (closed), and operating vacuum pump are turned on (refer to fig. 1).
(b) Canister pressure sensor
Indicates pressure as voltages. ECM supplies regulated 5 V to pressure sensor, and uses feedback from sensor to monitor EVAP system pressure (refer to fig 2).
(c) Vacuum pump
Creates negative pressure (vacuum) in EVAP system for leak check.
(d) 0.02 inch orifice
Has an opening with 0.02 inch diameter. Vacuum is produced through orifice by closing purge VSV, turning off vent valve and operating vacuum pump, to monitor 0.02 inch leak pressure. 0.02 inch leak pressure indicates a small leak of EVAP.

A118976E04


WIRING DIAGRAM

Refer to DTC P0450 .

INSPECTION PROCEDURE

NOTICE:
The Techstream is required to conduct the following diagnostic troubleshooting procedure.

HINT:
  1. Using the Techstream monitor results enables the EVAP (Evaporative Emission) system to be confirmed.
  2. Read freeze frame data using the Techstream. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can be helpful in determining whether the vehicle was running or stopped, whether the engine was warmed up or not, whether the air-fuel ratio was lean or rich, as well as other data recorded at the time of a malfunction.

1.CONFIRM DTC
  1. Turn the ignition switch off and wait for 10 seconds.

  1. Turn the ignition switch to the ON position.

  1. Turn the ignition switch off and wait for 10 seconds.

  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch to the ON position and turn the tester on.

  1. Select the following menus: Powertrain / Engine and ECT / Trouble Code.



  1. Confirm DTCs and freeze frame data.
    If any EVAP system DTCs are set, the malfunctioning area can be determined using the table below.


    A106731E16

    NOTICE:
    If the 0.02 inch reference pressure difference between the first and second checks is greater than the specification, the DTCs corresponding to the reference pressure (P043E, P043F, P0441, P0455, P0456, P2401 and P2420) will all be stored.


NEXT


2.PERFORM EVAPORATIVE SYSTEM CHECK (AUTO OPERATION)

NOTICE:
  1. In the Evaporative System Check (Automatic Mode), the series of 5 Evaporative System Check steps is performed automatically by the Techstream. It takes a maximum of approximately 18 minutes.
  2. Do not perform the Evaporative System Check when the fuel tank is more than 90% full because the cut-off valve may be closed, making the leak check of the fuel tank unavailable.
  3. Do not run the engine in this step.
  4. When the temperature of the fuel is 35°C (95°F) or more, a large amount of vapor forms and any check results become inaccurate. When performing the Evaporative System Check, keep the temperature below 35°C (95°F).

  1. Connect the Techstream to the DLC3.

  1. Clear the DTCs (Click here).

  1. Select the following menu items on the tester: Powertrain / Engine and ECT / Utility / Evaporative System Check / Automatic Mode.

  1. After the Evaporative System Check is completed, check for pending DTCs by selecting the following menu items: Powertrain / Engine and ECT / Trouble Code / Pending.

    HINT:
    If no pending DTC is displayed, perform the Monitor Confirmation after this repair is completed. After this confirmation, check for pending DTCs. If no DTC is displayed, the Evaporative system is normal.


NEXT


3.PERFORM EVAPORATIVE SYSTEM CHECK (MANUAL OPERATION)

G036782E11

NOTICE:
  1. In the Evaporative System Check (Manual Mode), the series of 5 Evaporative System Check steps is performed manually by the Techstream.
  2. Do not perform the Evaporative System Check when the fuel tank is more than 90% full because the cut-off valve may be closed, making the leak check of the fuel tank unavailable.
  3. Do not run the engine in this step.
  4. When the temperature of the fuel is 35°C (95°F) or more, a large amount of vapor forms and any check results become inaccurate. When performing the Evaporative System Check, keep the temperature below 35°C (95°F).

  1. Connect the Techstream to the DLC3.

  1. Clear the DTCs (Click here).

  1. Select the following menu items: Powertrain / Engine and ECT / Utility / Evaporative System Check / Manual Mode.


NEXT


4.PERFORM EVAPORATIVE SYSTEM CHECK (STEP 1/5)

G036783E06

  1. Check the EVAP pressure in step 1/5.

    Result:

    DTC*
    Test Result
    Suspected Trouble Area
    Proceed to
    -
    Virtually no variation in EVAP pressure
    Not yet determined
    A
    P0451
    EVAP pressure fluctuates by +/-0.3 kPa (2.25 mmHg) or more
    Pressure sensor noising
    B

    *: The DTCs relating to the Evaporative system displayed on the Techstream when checking.



B
Go to step 30
A


5.PERFORM EVAPORATIVE SYSTEM CHECK (STEP 1/5 TO 2/5)

G036784E06

  1. Check the EVAP pressure in steps 1/5 and 2/5.

    Result:

    DTC*
    Test Result
    Suspected Trouble Area
    Proceed to
    -
    Virtually no variation in EVAP pressure during step 1/5. Then decreases to 0.02 inch leak pressure standard*
    Not yet determined
    A
    P2402
    Small difference between EVAP pressures during steps 1/5 and 2/5
    Vacuum pump stuck ON
    B

    *: The DTCs related to the Evaporative system are displayed on the Techstream when checking.

    HINT:
    The first 0.02 inch leak pressure standard is the value determined in step 2/5.



B
Go to step 23
A


6.PERFORM EVAPORATIVE SYSTEM CHECK (STEP 2/5)

G036785E09

HINT:
Make a note of the pressures checked in steps (a) and (b) below.

  1. Check the EVAP pressure 4 seconds after the vacuum pump is activated*1 (Step (a)).

  1. Check the EVAP pressure again when it has stabilized. This pressure is the 0.02 inch leak pressure standard (Step (b)).
    *1: The vacuum pump begins to operate at the time step 2/5 starts.

    Result:

    DTC*2
    Test Result
    Suspected Trouble Area
    Proceed to
    -
    EVAP pressure in step (b) is between -4.85 kPa and -1.06 kPa (-36.38 mmHg and -7.95 mmHg)
    Not yet determined
    A
    P043F and P2401
    EVAP pressure in step (b) is -1.06 kPa (-7.95 mmHg) or more
    1. 0.02 inch orifice high-flow
    2. Vacuum pump stuck OFF
    B
    P043E
    EVAP pressure in step (b) is less than -4.85 kPa (-36.38 mmHg)
    0.02 inch orifice clogged
    C
    P2419
    EVAP pressure in step (a) is more than -1.06 kPa (-7.95 mmHg)
    Vent valve stuck closed
    D

    *2: The DTCs related to the Evaporative system are displayed on the Techstream when checking.



B
Go to step 11

C
Go to step 30

D
Go to step 19
A


7.PERFORM EVAPORATIVE SYSTEM CHECK (STEP 2/5 TO 3/5)

G036786E07

  1. Check the EVAP pressure increase in step 3/5.

    Result:

    DTC*
    Test Result
    Suspected Trouble Area
    Proceed to
    -
    EVAP pressure increases by 0.3 kPa (2.25 mmHg) or more within 10 seconds of proceeding from step 2/5 to step 3/5
    Not yet determined
    A
    P2420
    No variation in EVAP pressure even after proceeding from step 2/5 to step 3/5
    Vent valve stuck open (vent)
    B
    P0451
    No variation in EVAP pressure during steps 1/5 through 3/5
    Pressure sensor malfunction
    C

    *: The DTCs related to the Evaporative system are displayed on the Techstream when checking.



B
Go to step 20

C
Go to step 30
A


8.PERFORM EVAPORATIVE SYSTEM CHECK (STEP 3/5)

G038126E08

  1. Wait until the EVAP pressure change is less than 0.1 kPa (0.75 mmHg) for 30 seconds.

  1. Measure the EVAP pressure and record it.

    HINT:
    A few minutes are required for the EVAP pressure to become saturated. When there is little fuel in the fuel tank, it takes up to 15 minutes.


NEXT


9.PERFORM EVAPORATIVE SYSTEM CHECK (STEP 4/5)

G036776E16

  1. Check the EVAP pressure in step 4/5.

    Result:

    DTC*
    Test Result
    Suspected Trouble Area
    Proceed to
    -
    EVAP pressure increases by 0.3 kPa (2.25 mmHg) or more within 10 seconds of proceeding from step 3/5 to step 4/5
    Not yet determined
    A
    P0441
    EVAP pressure increases by 0.3 kPa (2.25 mmHg) or more within 10 seconds of proceeding from step 3/5 to step 4/5
    Problems in EVAP hose between purge VSV and intake manifold
    B
    P0441
    Variation in EVAP pressure is less than 0.3 kPa (2.25 mmHg) for 10 seconds, after proceeding from step 3/5 to step 4/5
    Purge VSV stuck closed
    C

    *: The DTCs related to the Evaporative system are displayed on the Techstream when checking.



B
Go to step 15

C
Go to step 12
A


10.PERFORM EVAPORATIVE SYSTEM CHECK (STEP 5/5)

G036782E12

  1. Check the EVAP pressure in step 5/5.

  1. Compare the EVAP pressure in step 3/5 and the second 0.02 inch leak pressure standard (step 5/5).

    Result:

    DTC*
    Test Result
    Suspected Trouble Area
    Proceed to
    -
    EVAP pressure (step 3/5) lower than second 0.02 inch leak pressure standard (step 5/5)
    Not yet determined (no leakage from EVAP system)
    A
    P0441 and P0455
    EVAP pressure (step 3/5) higher than [second 0.02 inch leak pressure standard (step 5/5) x 0.2]
    1. Purge VSV stuck open
    2. EVAP gross leak
    B
    P0456
    EVAP pressure (step 3/5) higher than second 0.02 inch leak pressure standard (step 5/5)
    EVAP small leak
    B

    *: The DTCs related to the Evaporative system are displayed on the Techstream when checking.



A
Go to step 36

B
Go to step 12

11.PERFORM EVAPORATIVE SYSTEM CHECK (STEP 3/5)

G036788E07

  1. Check the EVAP pressure in step 3/5.

    Result:

    DTC*
    Test Result
    Suspected Trouble Area
    Proceed to
    P043F
    EVAP pressure is less than [0.02 inch leak pressure standard] measured in step 2/5
    0.02 inch orifice high-flow
    A
    P2401
    EVAP pressure is almost the same as [0.02 inch leak pressure standard] measured in step 2/5
    Vacuum pump stuck OFF
    B

    *: The DTCs related to the Evaporative system are displayed on the Techstream when checking.

    HINT:
    The first 0.02 inch leak pressure standard is the value determined in step 2/5.



A
Go to step 30

B
Go to step 23

12.PERFORM ACTIVE TEST USING TECHSTREAM (PURGE VSV)


    A136286E01
  1. Select the following menu items on the tester: Powertrain / Engine and ECT / Active Test / Activate the VSV for EVAP Control.

  1. Disconnect the hose (connected to the canister) from the purge VSV.

  1. Start the engine.

  1. Using the tester, turn off the purge VSV (EVAP VSV: OFF).

  1. Confirm that the purge VSV has no suction with your fingers.

  1. Using the tester, turn on the purge VSV (EVAP VSV: ON).

  1. Confirm that the purge VSV has suction with your fingers.

    Result:
    Test Result
    Suspected Trouble Area
    Proceed to
    No suction when purge VSV turned OFF, and suction applied when turned ON
    -
    A
    Suction applied when purge VSV turned OFF
    Purge VSV stuck open
    B
    No suction when purge VSV turned ON
    1. Purge VSV stuck closed
    2. Problems with EVAP hose between purge VSV and throttle body
    C

  1. Reconnect the hose.



B
Go to step 14

C
Go to step 15
A


13.CHECK FUEL TANK CAP ASSEMBLY
  1. Check that the fuel tank cap is correctly installed and confirm the fuel tank cap meets OEM specification.

    HINT:
    If an EVAP tester is available, check the fuel tank cap using the tester.

    1. Tighten the fuel tank cap

    2. Remove the fuel tank cap and install it onto the fuel tank cap adaptor.

    3. Connect the EVAP tester pump hose to the adaptor, and pressurize the cap to 3.2 to 3.7 kPa (24 to 28 mmHg) using an EVAP tester pump.

    4. Seal the adaptor and wait for 2 minutes.

    5. Check the pressure. If the pressure is 2 kPa (15 mmHg) or more, the fuel tank cap is normal.

      Result:

      Test Result
      Suspected Trouble Area
      Proceed to
      Fuel tank cap correctly installed
      -
      A
      Fuel tank cap loose
      1. Fuel tank cap improperly installed
      2. Defective fuel tank cap
      3. Fuel tank cap does not meet OEM specifications
      B
      No fuel tank cap
      -
      C



A
Go to step 29

B
Go to step 27

C
Go to step 28

14.INSPECT PURGE VSV


    A136287E01
  1. Turn the ignition switch off.

  1. Disconnect the V3 purge VSV connector.

  1. Disconnect the hose (connected to the canister) from the purge VSV.

  1. Start the engine.

  1. Confirm that the purge VSV has no suction with your fingers.

    Result:
    Test Result
    Suspected Trouble Area
    Proceed to
    No suction
    ECM
    A
    Suction applied
    Purge VSV
    B

  1. Reconnect the purge VSV connector.

  1. Reconnect the hose.



A
Go to step 35

B
Go to step 31

15.CHECK EVAP HOSE (PURGE VSV - THROTTLE BODY)


    A136288E02
  1. Disconnect the hose (connected to the throttle body) from the purge VSV.

  1. Start the engine.

  1. Confirm that the hose has suction with your fingers.

    Result:
    Test Result
    Suspected Trouble Area
    Proceed to
    Suction applied
    -
    A
    No suction
    1. Throttle body
    2. EVAP hose between purge VSV and throttle body
    B

  1. Reconnect the hose.



B
Go to step 26
A


16.INSPECT VACUUM SWITCHING VALVE NO. 1 (PURGE VSV)


    A136289E01
  1. Remove the purge VSV.

  1. Apply battery voltage to the terminals of the purge VSV.

  1. Using compressed air, confirm that air flows from port A to port B.

    Result:
    Test Result
    Suspected Trouble Area
    Proceed to
    Air flows
    -
    A
    No air flow
    Purge VSV
    B

  1. Install the purge VSV.



B
Go to step 31
A


17.CHECK HARNESS AND CONNECTOR (POWER SOURCE OF PURGE VSV)


    A052933E47
  1. Disconnect the V3 purge VSV connector.

  1. Turn the ignition switch to the ON position.

  1. Measure the voltage between terminal 1 of the purge VSV connector and body ground.

    Result:
    Test Result
    Suspected Trouble Area
    Proceed to
    Between 11 V and 14 V
    -
    A
    Other than result above
    Wire harness or connectors between purge VSV and ECM
    B

  1. Reconnect the purge VSV connector.



B
Go to step 32
A


18.CHECK HARNESS AND CONNECTOR (PURGE VSV - ECM)


    A114636E07
  1. Disconnect the E9 ECM connector and the V3 purge VSV connector.

  1. Measure the resistance between the terminals of the purge VSV connector and ECM connector.

    Standard resistance:
    Tester Connection
    Specified Condition
    E9-34 (PRG) - V3-2
    Below 1 Ω
    E9-34 (PRG) - Body ground
    10 kΩ or higher
    V3-1 - Body ground
    10 kΩ or higher

  1. Reconnect the purge VSV connector.

  1. Reconnect the ECM connector.



OK
Go to step 35

NG
Go to step 32

19.PERFORM ACTIVE TEST USING TECHSTREAM (FOR VENT VALVE)


    A162489E07
  1. Turn the ignition switch to the ON position.

  1. Select the following menu items on the tester: Powertrain / Engine and ECT / Active Test / Activate the VSV for Vent Valve.

  1. Measure the voltage between terminal VPMP of the ECM connector and body ground when the vent valve is turned ON (close) and OFF (vent) using the tester.

    Result:
    Test Result
    Suspected Trouble Area
    Proceed to
    Between 9 V and 14 V when OFF
    Below 3 V when ON
    Vent valve
    A
    Below 3 V when OFF and ON
    ECM
    B



A
Go to step 22

B
Go to step 35

20.PERFORM ACTIVE TEST USING TECHSTREAM (FOR VENT VALVE)


    A162489E07
  1. Turn the ignition switch to the ON position.

  1. Select the following menu items on the tester: Powertrain / Engine and ECT / Active Test / Activate the VSV for Vent Valve.

  1. Measure the voltage between terminal VPMP of the ECM connector and body ground when the vent valve is turned ON (close) and OFF (vent) using the tester.

    Result:
    Test Result
    Suspected Trouble Area
    Proceed to
    Below 3 V when OFF and ON
    Power source of vent valve
    A
    Between 9 V and 14 V when OFF
    Below 3 V when ON
    Vent valve
    B
    Between 9 V and 14 V when OFF and ON
    ECM
    C



B
Go to step 22

C
Go to step 35
A


21.INSPECT PUMP MODULE (POWER SOURCE FOR VENT VALVE)


    A165552E02
  1. Turn the ignition switch off.

  1. Disconnect the C27 canister pump module connector.

  1. Turn the ignition switch to the ON position.

  1. Measure the voltage between terminal 9 of the canister connector and body ground.

    Result:
    Test Result
    Suspected Trouble Area
    Proceed to
    Between 9 V and 14 V
    -
    A
    Between 0 V and 3 V
    Power source wire harness of vent valve
    B

  1. Reconnect the canister pump module connector.



B
Go to step 32
A


22.INSPECT PUMP MODULE (VENT VALVE OPERATION)


    A096743E08
  1. Turn the ignition switch off.

  1. Disconnect the C27 canister pump module connector.

  1. Apply the battery voltage to terminals 9 and 8 of the pump module.

  1. Touch the pump module to confirm the vent valve operation.

    Result:
    Test Result
    Suspected Trouble Area
    Proceed to
    Operating
    Wire harness between vent valve and ECM
    A
    Not operating
    Vent valve
    B

  1. Reconnect the canister pump module connector.



A
Go to step 32

B
Go to step 30

23.PERFORM ACTIVE TEST USING TECHSTREAM (FOR PUMP MODULE (VACUUM PUMP))


    A162489E08
  1. Select the following menu items on the tester: Powertrain / Engine and ECT / Active Test / Activate the Vacuum Pump.

  1. Measure the voltage between terminal MPMP of the ECM connector and body ground when the vacuum pump is turned ON and OFF using the tester.

    Result:
    Test Result
    Suspected Trouble Area
    Proceed to
    Between 0 V and 3 V when OFF
    Between 9 V and 14 V when ON
    -
    A
    Between 9 V and 14 V when OFF
    Between 0 V and 3 V when ON
    ECM
    B



B
Go to step 35
A


24.CHECK HARNESS AND CONNECTOR (PUMP MODULE - ECM)


    A165552E02
  1. Turn the ignition switch off.

  1. Disconnect the C27 canister pump module connector.

  1. Turn the ignition switch to the ON position.

  1. Select the following menu items on the tester: Powertrain / Engine and ECT / Active Test / Activate the Vacuum Pump.

  1. Turn the vacuum pump ON.

  1. Measure the voltage between terminal 1 of the canister connector and body ground.

    Result:
    Test Result
    Suspected Trouble Area
    Proceed to
    Between 9 V and 14 V
    -
    A
    Between 0 V and 3 V
    Wire harness between ECM and vacuum pump
    B

  1. Reconnect the canister pump module connector.



B
Go to step 32
A


25.CHECK HARNESS AND CONNECTOR (PUMP MODULE - BODY GROUND)


    A085258E73
  1. Disconnect the C27 canister pump module connector.

  1. Turn the ignition switch off.

  1. Check the resistance between terminal 6 of the canister connector and body ground.

    Result:
    Test Result
    Suspected Trouble Area
    Proceed to
    Below 1 Ω
    Vacuum Pump
    A
    10 kΩ or higher
    Wire harness between vacuum pump and body ground
    B

  1. Reconnect the canister pump module connector.



A
Go to step 30

B
Go to step 32

26.INSPECT THROTTLE BODY
  1. Stop the engine.

  1. Disconnect the EVAP hose from the throttle body.

  1. Start the engine.

  1. Confirm that the port of the throttle body has suction with your fingers.


Result:

Test Result
Suspected Trouble Area
Proceed to
Suction applied
EVAP hose between throttle body and purge VSV
A
No suction
Throttle body
B

  1. Reconnect the EVAP hose.



A
Go to step 33

B
Go to step 34

27.CORRECTLY REINSTALL OR REPLACE FUEL TANK CAP

HINT:
  1. When reinstalling the fuel tank cap, tighten it until a few click sounds are heard.
  2. When replacing the fuel tank cap, use a fuel tank cap that meets OEM specifications, and tighten it until a few click sounds are heard.



NEXT
Go to step 37

28.REPLACE FUEL TANK CAP ASSEMBLY

HINT:
When installing the fuel tank cap, tighten it until a few click sounds are heard.



NEXT
Go to step 37

29.LOCATE EVAP LEAK


  1. Disconnect the vent hose.


    A163294E02



  1. Connect the EVAP pressure tester tool to the canister with the adapter.


    A137044E01

  1. Pressurize the EVAP system by 3.2 to 3.7 kPa (24 to 28 mmHg).

  1. Apply soapy water to the piping and the connecting parts of the EVAP system.

  1. Look for areas where bubbles appear. This indicates a leak point.

  1. Repair or replace the leak point.



NEXT
Go to step 37

30.REPLACE CHARCOAL CANISTER ASSEMBLY


  1. Replace the charcoal canister assembly (Click here).

    NOTICE:
    When replacing the canister, check the canister pump module interior and related pipes for water, fuel and other liquids. If liquids are present, check for disconnections and/or cracks in the following: 1) the pipe from the air inlet port to the canister pump module; 2) the canister filter; 3) the fuel tank vent hose.


    A163294E01



NEXT
Go to step 37

31.REPLACE VACUUM SWITCHING VALVE NO. 1 (PURGE VSV)


    A136285E01
  1. Disconnect the connector and 2 hoses from the purge VSV.

  1. Remove the purge VSV.

  1. Install a new purge VSV.

  1. Reconnect the connector and 2 hoses.



NEXT
Go to step 37

32.REPAIR OR REPLACE HARNESS OR CONNECTOR


NEXT
Go to step 37

33.REPLACE EVAP HOSE (THROTTLE BODY - PURGE VSV)


NEXT
Go to step 37

34.INSPECT THROTTLE BODY
  1. Remove the throttle body (Click here).

  1. Check that the EVAP purge port of the throttle body is not clogged. If necessary, replace the throttle body.



NEXT
Go to step 37

35.REPLACE ECM
  1. Replace the ECM (Click here).



NEXT
Go to step 37

36.REPAIR OR REPLACE PARTS AND COMPONENTS INDICATED BY OUTPUT DTCS
  1. Repair the malfunctioning areas indicated by the DTCs that had been confirmed when the vehicle was brought in.


NEXT


37.PERFORM EVAPORATIVE SYSTEM CHECK (AUTO OPERATION)

NOTICE:
  1. In the Evaporative System Check (Automatic Mode), the series of 5 Evaporative System Check steps are performed automatically. It takes a maximum of approximately 18 minutes.
  2. Do not perform the Evaporative System Check when the fuel tank is more than 90% full because the cut-off valve may be closed, making the leak check of the fuel tank unavailable.
  3. Do not run the engine in this step.
  4. When the temperature of the fuel is 35°C (95°F) or more, a large amount of vapor forms and any check results become inaccurate. When performing an Evaporative System Check, keep the temperature below 35°C (95°F).

  1. Clear the DTCs (Click here).

  1. On the Techstream, select the following menu items: Powertrain / Engine and ECT / Utility / Evaporative System Check / Automatic Mode.

  1. After the Evaporative System Check is completed, check for pending DTCs by selecting the following menu items: Powertrain / Engine and ECT / Trouble Code / Pending.

    HINT:
    If no pending DTC is found, the repair has been successfully completed.


NEXT

COMPLETED