1.RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM
16470
2.REMOVE RADIATOR RESERVE TANK ASSEMBLY
88719A
3.REMOVE AIR CONDITIONER PRESSURE SENSOR
Residual pressure in the air conditioning.
Danger of injury.
Wear safety goggles and protective gloves when disconnecting the refrigerant line.
Seal refrigerant lines with seal plugs.
Disconnect the connector (1).
Using a deep socket wrench 24 mm, remove the air conditioner pressure sensor (2).