89465
1.INSTALL OXYGEN SENSOR
Check the thread (1) and sensor ceramics (2) for damage and replace the oxygen sensor, if necessary.
For oxygen sensors that are reused, the following should be observed.
Do not clean the part of the oxygen sensor that does not protrude into the exhaust branch (sensor ceramics).
| *a | Torque Wrench Fulcrum Length |
Using SST, install the oxygen sensor (1).
Calculate the torque wrench reading when changing the fulcrum length of the torque wrench.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
When using SST (fulcrum length of 30 mm (1.18 in.)) + torque wrench (fulcrum length of 180 mm (7.09 in.)):
42.9 N*m (437 kgf*cm, 32 ft.*lbf)
Engage the line of the oxygen sensor (2) in the holders (1).
Engage connector (1) on the holder (2).
Connect connectors and lock.
2.INSTALL AIR CLEANER CAP SUB-ASSEMBLY
12601B
3.INSTALL NO. 1 ENGINE COVER SUB-ASSEMBLY