Home › Engine / Hybrid System › B48 (COOLING) › WATER INLET HOUSING
RM3650E _51 Engine / Hybrid System _080127 B48 COOLING _0388805 WATER INLET HOUSING A

B48 COOLING  WATER INLET HOUSING  REMOVAL  


PROCEDURE

Hide 51219 1.REMOVE FRONT SUSPENSION MEMBER LOWER PROTECTOR

Hide 2. DRAIN ENGINE COOLANT (for High Temperature)

Hide 27020 3.REMOVE GENERATOR ASSEMBLY

Hide 16032 4.REMOVE WATER INLET WITH WATER PUMP HOUSING SUB-ASSEMBLY

a.
A433990

Release the E10 bolts (1) and remove the No. 3 water pump bracket sub-assembly.


b.
A441814

Unscrew the T30 bolts (1) and remove the No. 2 water by-pass hose (2).


c.

Unlock the No. 1 radiator hose (3) and remove.


d.

Catch and dispose of escaping coolant.


e.
A441817

Loosen E10 bolt (1).


f.

Remove automatic transmission oil cooler tube clamp (2).


g.
A441815

Unlock and remove the No. 3 water by-pass pipe (1) and set it aside.


h.

Unlock the lock (2) and remove the No. 1 water by-pass hose with switch valve (3).


i.

Catch and dispose of escaping coolant.


j.
A441816

Loosen E10 bolts (1).


k.

Guide out the water inlet with water pump housing sub-assembly (2) and remove.


l.

Catch and dispose of escaping coolant.