Home › Engine / Hybrid System › B48 (COOLING) › WATER INLET HOUSING
RM3650E _51 Engine / Hybrid System _080127 B48 COOLING _0388805 WATER INLET HOUSING A

B48 COOLING  WATER INLET HOUSING  INSTALLATION  


PROCEDURE

Hide 16032 1.INSTALL WATER INLET WITH WATER PUMP HOUSING SUB-ASSEMBLY

a.
A441819

Replace the gasket (1).


b.

Insert and install the seal (1) on the water inlet with water pump housing sub-assembly.


c.
A441818

Clean the sealing surface (1).


d.
A441816

Insert and install the water inlet housing sub-assembly (engine water pump) (2).


e.

Tighten the E10 bolts (1).

Torque:
19 N*m (194 kgf*cm, 14 ft.*lbf)


f.
A441815

Install the No. 1 water by-pass hose with switch valve (3).

HINT:

Make sure that the connections are locked correctly. The locks must engage audibly.



g.

Connect the No. 3 water by-pass pipe (1).

HINT:

Make sure that the connections are locked correctly. The locks must engage audibly.



h.
A441817

Install automatic transmission oil cooler tube clamp (2).


i.

Tighten down E10 bolts (1).

Torque:
8.0 N*m (82 kgf*cm, 71 in.*lbf)


j.
A441814

Install the No. 1 radiator hose (3).

HINT:

Make sure that the connections are locked correctly. The locks must engage audibly.



k.

Install the No. 2 water by-pass hose (2).


l.

Tighten the T30 bolts (1).

Torque:
8.0 N*m (82 kgf*cm, 71 in.*lbf)


m.
A433990

Install No. 3 water pump bracket sub-assembly.


n.

Tighten down E10 bolts (1).

Torque:
19 N*m (194 kgf*cm, 14 ft.*lbf)


Hide 27020 2.INSTALL GENERATOR ASSEMBLY

Hide 3.ADD ENGINE COOLANT (for High Temperature)

Hide 4.INSPECT FOR COOLANT LEAK (for High Temperature)

Hide 51219 5.INSTALL FRONT SUSPENSION MEMBER LOWER PROTECTOR