12601B
1.REMOVE NO. 1 ENGINE COVER SUB-ASSEMBLY
17882
2.REMOVE NO. 2 AIR CLEANER HOSE
11401T
3.REMOVE CYLINDER BLOCK COVER
Loosen clamps (1).
Release all expanding rivets in marked areas.
Guide out the cylinder block cover (2).
16109
4.REMOVE WATER PUMP SUB-ASSEMBLY
Unlock and loosen connector (1).
Unscrew the nut (2) on the holder.
Guide the water pump sub-assembly (3) out of the holder and set it aside.
5.REMOVE FAN AND GENERATOR V BELT
Component with preload.
Danger of injury!
Reduce preload as far as possible before disassembly. Relieve component.
If the fan and generator V belt is reused: Mark the direction of travel and reinstall the fan and generator V belt in same direction of travel.
| *a | 4 mm Hexagon Wrench |
Using 16 mm socket, raise the preloading on the belt tensioner (1) in the direction of arrow.
Secure the belt tensioner (1) with the 4 mm hexagon wrench.
Guide out the fan and generator V belt (1) and remove it.