16620D
1.INSTALL V-RIBBED BELT TENSIONER ASSEMBLY
Component with preload.
Danger of injury!
Reduce preload as far as possible before disassembly. Relieve component.
Position the v-ribbed belt tensioner assembly of the generator assembly.
Tighten the bolts.
| *a | 4 mm Hexagon Wrench |
Increase the preload of the v-ribbed belt tensioner assembly of the generator assembly on the hexagon head (1).
Secure the v-ribbed belt tensioner assembly of the generator assembly with the 4 mm hexagon wrench.
17882
2.INSTALL NO. 2 AIR CLEANER HOSE
16020
3.CONNECT ELECTRIC WATER PUMP ASSEMBLY
4.INSTALL FAN AND GENERATOR V BELT