HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM  PRECAUTION  


REFRIGERANT CIRCUIT IS UNDER HIGH PRESSURE


·

If the service valve caps on the service valves are difficult to open, there is a danger of injury from leaking valve inserts.



REPAIRS MAY ONLY BE CARRIED OUT ON A DEPRESSURIZED REFRIGERANT CIRCUIT


·

Before conducting repairs, check the actual pressure drop.



AVOID CONTACT WITH REFRIGERANT AND COMPRESSOR OIL


·

Pay attention to the safety information for dealing with coolant.



RESTART ENGINE ONLY WHEN AIR CONDITIONING HAS BEEN CORRECTLY FILLED



ALWAYS USE NEW O-RINGS EACH TIME A/C CONNECTIONS ARE OPENED


·

They must not be coated.



OPEN THE REFRIGERANT CIRCUIT FOR AS SHORT A PERIOD AS POSSIBLE



DURING THE ENTIRE FILLING PROCEDURE THE VEHICLE MUST STAND ON THE FLOOR



FILLING A RAISED VEHICLE WILL RESULT IN INSUFFICIENT FILLING LEVELS



PERFORM A/C PERFORMANCE TEST IN EVENT OF CUSTOMER COMPLAINT


Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM>ON-VEHICLE INSPECTION


INSTRUCTIONS FOR DRAWING OFF AIR CONDITIONING


a.

To help separation of refrigerant and compressor oil, run engine at low speed (800 to 1200 rpm) and with air conditioning switched on for a few minutes.

i.

This limits the entrainment of compressor oil while it is drawn off.



b.

Drawn-off compressor oil must be changed and reintroduced via the refrigerant recovery unit.


c.

During drawing off, set the blower of the heating and air conditioning unit to the middle blower speed.

i.

This ensures that drawing off is more effective since the pressure on the low pressure side increases.




INSTRUCTIONS FOR EVACUATING OFF AIR CONDITIONING


a.

Before each filling, evacuate the refrigerant circuit.


b.

Observe an evacuation time of at least 30 minutes.


c.

The evacuation procedure removes all traces of ambient air, water vapor and any other gases present from the air conditioning. This enables subsequent system filling with refrigerant.


d.

If the vacuum does not remain stable when the system is off, run the procedure for leaks in the refrigerant circuit.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT>PRECAUTION


e.

During evacuation, set the blower of the heating and air conditioning unit to the middle blower speed.

i.

This ensures that evacuation is more effective since the pressure on the low pressure side increases.




INSTRUCTIONS FOR FILLING AIR CONDITIONING


a.

Before filling with refrigerant, replace the compressor oil entrained plus losses during drawing off.


b.

Fill up the amount of refrigerant as per type plate.