Home › ENGINE ยท 2TR-FE › ENGINE CONTROL SYSTEM › SFI SYSTEM

SFI SYSTEM > DATA LIST / ACTIVE TEST

for Preparation Click here



DATA LIST

HINT:
By reading the DATA LIST displayed on a intelligent tester, you can check values, including those of the switches, sensors, and actuators, without removing any parts. Reading the DATA LIST as the first step of troubleshooting is one method of shortening diagnostic time.

NOTICE:
In the table below, the values listed under Normal Conditions are for reference only. Do not depend solely on these values when determining whether or not a part is faulty.

  1. Warm up the engine.

  2. Turn the ignition switch to OFF

  3. Connect a intelligent tester to the DLC3.

  4. Turn the ignition switch to ON.

  5. Turn the tester ON.

  6. Select the following menu items: DIAGNOSIS / ENHANCED OBD II / DATA LIST.

  7. Check the values by referring to the table below.

    Intelligent Tester Display
    Measurement Item: Range
    (Display)
    Normal Condition *
    Diagnostic Note
    INJECTOR
    Injection period of No. 1 cylinder:
    Min.: 0 ms, Max.: 32.64 ms
    1.8 to 3.8 ms: Idling
    -
    IGN ADVANCE
    Ignition timing advance for No. 1 cylinder:
    Min.: -64 deg., Max.: 63.5 deg.
    BTDC 4 to 17°: Idling
    -
    CALC LOAD
    Calculated load by ECM:
    Min.: 0 %, Max.: 100 %
    1. 11 to 26 %: Idling
    2. 12 to 27 %: Running without load
      (2,500 rpm)
    -
    VEHICLE LOAD
    Vehicle load:
    Min.: 0 %, Max.: 25700 %
    Actual vehicle load
    -
    MAF
    Air flow rate from MAF meter:
    Min.: 0 g/sec, Max.: 655.35 g/sec
    2.0 to 4.5 g/sec: Idling
    If value approximately 0.0 g/sec:
    1. Mass air flow meter power source circuit open
    2. VG circuit open or short
    If value 160.0 g/sec or more:
    1. E2G circuit open
    ENGINE SPD
    Engine speed:
    Min.: 0 rpm, Max.: 16,383.75 rpm
    650 +- 50 rpm: Idling
    -
    VEHICLE SPD
    Vehicle speed:
    Min.: 0 km/h, Max.: 255 km/h
    Actual vehicle speed
    Speed indicated on speedometer
    COOLANT TEMP
    Engine coolant temperature:
    Min.: -40°C, Max.: 140°C
    80 to 100°C
    (176 to 212°F): After warming up
    1. If value -40°C (-40°F): sensor circuit open
    2. If value 140°C (284°F): sensor circuit shorted
    INTAKE AIR
    Intake air temperature:
    Min.: -40°C, Max.: 140°C
    Equivalent to ambient air temperature
    1. If value -40°C (-40°F): sensor circuit open
    2. If value 140°C (284°F): sensor circuit shorted
    SECONDARY AIR
    Secondary air injection system status:
    ON or OFF
    ON: Secondary air system operation
    -
    AIR-FUEL RATIO
    Air-fuel ratio:
    Min.: 0, Max.: 1.999
    0.8 to 1.2: Idling
    -
    PURGE DENSITY
    Learning value of purge density:
    Min.: -50, Max.: 350
    -40 to 0 %: Idling
    Service data
    PURGE FLOW
    Purge flow:
    Min.: 0 %, Max.: 102.4 %
    0 to 100 %: Idling
    -
    EVAP PURGE VSV
    EVAP (Purge) VSV control duty:
    Min.: 0 %, Max.: 100 %
    0 to 100 %: During idling
    Order signal from ECM
    VAPOR PRESS
    Vapor pressure:
    Min.: 33.853 kPa, Max.: 125.596 kPa
    Approximately 100 kPa: Ignition switch ON
    EVAP system pressure monitored by canister pressure sensor
    VAPOR PRESS CALC
    Calculated EVAP system pressure:
    Min.: -5.632 kPa, Max.: 715.264 kPa
    Approximately 100 kPa: Ignition switch ON
    -
    KNOCK CRRT VAL
    Correction learning value of knocking:
    Min.: -64 °CA, Max.: 1,984 °CA
    0 to 19 °CA:
    Driving, 44 mph (70 km/h)
    Service data
    KNOCK FB VAL
    Feedback value of knocking:
    Min.: -64 °CA, Max.: 1,984 °CA
    -19 to 0 °CA
    Driving, 44 mph (70 km/h)
    Service data
    EVAP VAPOR PRES
    EVAP vapor pressure:
    Min.: 0 kPa, Max.: 327.675 kPa
    Approximately 100 kPa: Ignition switch ON
    -
    ACCEL POS #1
    Absolute No. 1 Accelerator Pedal Position (APP):
    Min.: 0 %, Max.: 100 %
    10 to 22 %: Accelerator pedal released
    54 to 86 %: Accelerator pedal fully depressed
    -
    ACCEL POS #2
    Absolute No. 2 APP:
    Min.: 0 %, Max.: 100 %
    12 to 42 %: Accelerator pedal released
    66 to 98 %: Accelerator pedal fully depressed
    -
    ACCEL POS #1
    No. 1 APP sensor voltage:
    Min.: 0 V, Max.: 4.98 V
    -
    ETCS freeze data
    ACCEL POS #2
    No. 2 APP sensor voltage:
    Min.: 0 V, Max.: 4.98 V
    -
    ETCS freeze data
    ACCEL POS #1
    No. 1 APP sensor voltage:
    Min.: 0 V, Max.: 5 V
    0.5 to 1.1 V: accelerator pedal released
    2.6 to 4.5 V: or pedal fully depressed
    -
    ACCEL POS #2
    No. 2 APP sensor voltage:
    Min.: 0 V, Max.: 5 V
    1.2 to 2.0 V: accelerator pedal released
    3.4 to 5.3 V: accelerator pedal fully depressed.
    -
    ACCEL IDL POS
    Whether or not accelerator pedal position sensor detecting idle:
    ON or OFF
    ON: Idling
    -
    THRTL LEARN VAL
    Throttle valve fully closed (learned value):
    Min.: 0 V, Max.: 5 V
    0.4 to 0.8 V
    -
    ACCEL SSR #1 AD
    No.1 Accelerator fully closed value (AD):
    Min.: 0 V, Max.: 4.9804 V
    -
    ETCS service data
    ACCEL LRN VAL#1
    No.1 Accelerator fully closed learning value:
    Min.: 0, Max.: 124.512
    -
    ETCS service data
    ACCEL LRN VAL#2
    No.2 Accelerator fully closed learning value:
    Min.: 0, Max.: 124.512
    -
    ETCS service data
    FAIL #1
    Whether or not fail safe function executed:
    ON or OFF
    ON: ETCS has failed
    -
    FAIL #2
    Whether or not fail safe function executed:
    ON or OFF
    ON: ETCS has failed
    -
    ST1
    Starter signal:
    ON or OFF
    ON: Cranking
    -
    SYSGUARD JUDGE
    System guard:
    ON or OFF
    -
    ETCS service data
    OPN MALFUNCTION
    Open side malfunction:
    ON or OFF
    -
    ETCS service data
    THROTTLE POS
    Absolute throttle position sensor:
    Min.: 0 %, Max.: 100 %
    1. 10 to 24 %: Throttle fully closed
    2. 64 to 96 %: Throttle fully open
    Read value with intrusive operation (active test)
    THROTTL IDL POS
    Whether or not throttle position sensor detecting idle:
    ON or OFF
    ON: Idling
    -
    THRTL REQ POS
    Throttle requirement position:
    Min.: 0 V, Max.: 5 V
    0.5 to 1.0 V: Idling
    -
    THROTTLE POS
    Throttle sensor positioning:
    Min.: 0 % Max.: 100 %
    0 to 10 %: Idling
    Calculated value based on VTA1
    THROTTLE POS #2
    Throttle sensor positioning #2:
    Min.: 0 %, Max.: 100 %
    -
    Calculated value based on VTA2
    THROTTLE POS #1
    No. 1 Throttle position sensor output voltage:
    Min.: 0 V, Max.: 4.9 V
    -
    ETCS freeze data
    THROTTLE POS #2
    No.2 Throttle position sensor output voltage:
    Min.: 0 V, Max.: 4.9 V
    -
    ETCS freeze data
    THROTTLE POS #1
    No. 1 Throttle position:
    Min.: 0 V, Max.: 5 V
    1. 0.5 to 1.2 V: Throttle fully closed
    2. 3.2 to 4.8 V: Throttle fully opened
    -
    THROTTLE POS #2
    No. 2 Throttle position:
    Min.: 0 V, Max.: 5 V
    1. 2.0 to 2.9 V: Throttle fully closed
    2. 4.6 to 5.5 V: Throttle fully open
    Read value with intrusive operation (active test)
    THRTL COMND VAL
    Throttle position command value:
    Min.: 0 V, Max.: 4.9804 V
    0.5 to 4.8 V
    ETCS service data
    THROTTLE SSR #1
    No. 1 Throttle sensor opener position:
    Min.: 0 V, Max.: 4.9804 V
    0.6 to 1.0 V
    ETCS service data
    THROTTLE SSR #2
    No. 2 Throttle sensor opener position:
    Min.: 0 V, Max.: 4.9804 V
    2.0 to 2.6 V
    ETCS service data
    THRTL SSR #1 AD
    No.1 Throttle sensor opener position (AD):
    Min.: 0 V, Max.: 4.9804 V
    0.6 to 0.9 V
    ETCS service data
    THROTTLE MOT
    Whether or not throttle motor control permitted:
    ON or OFF
    ON: Idling
    Read value with ignition switch ON (Do not start engine)
    THROTTLE MOT
    Throttle motor current:
    Min.: 0 A, Max.: 80 A
    0 to 3.0 A: Idling
    -
    THROTTLE MOT
    Throttle motor:
    Min.: 0 % Max.: 100 %
    0.5 to 40 %: Idling
    -
    THROTTLE MOT
    Throttle motor current:
    Min.: 0 A, Max.: 19.92 A
    0 to 3.0 A: Idling
    -
    THROTL OPN DUTY
    Throttle motor opening duty ratio:
    Min.: 0 %, Max.: 100 %
    0 to 40 %: Idling
    When accelerator pedal depressed, duty ratio increased
    THROTL CLS DUTY
    Throttle motor closed duty ratio::
    Min.: 0 %, Max.: 100 %
    0 to 40 %: Idling
    When accelerator pedal released quickly, duty ratio increased
    THRTL MOT (OPN)
    Throttle motor duty ratio (open):
    Min.: 0 %, Max.: 100 %
    -
    ETCS service data
    THRTL MOT (CLS)
    Throttle motor duty ratio (close):
    Min.: 0 %, Max.: 100 %
    -
    ETCS service data
    O2S B1 S2
    Heated oxygen sensor output voltage for bank 1 sensor 2:
    Min.: 0 V, Max.: 1.275 V
    0 to 0.9 V:
    Driving 44 mph (70 km/h)
    Performing INJ VOL or A/F CONTROL function of ACTIVE TEST enables technician to check voltage output of sensor
    AFS B1 S1
    A/F sensor output voltage for bank 1 sensor 1:
    Min.: 0 V, Max.: 7.999 V
    2.8 to 3.8 V: Idling
    Performing INJ VOL or A/F CONTROL function of ACTIVE TEST enables technician to check voltage output of sensor
    TOTAL FT #1
    Total fuel trim of bank 1
    Average value for fuel trim system of bank 1:
    Min.: -0.5, Max.: 0.496
    -0.2 to 0.2: Idling
    -
    SHORT FT #1
    Short-term fuel trim of bank 1:
    Min.: -100 %, Max.: 99.2%
    0 +- 20 %
    Short-term fuel compensation used to maintain air-fuel ratio at stoichiometric air-fuel ratio
    LONG FT #1
    Long-term fuel trim of bank 1:
    Min.: -100 %, Max.: 99.2 %
    0 +- 20 %
    Overall fuel compensation carried out in long-term to compensate continual deviation of short-term fuel trim from central value
    FUEL SYS #1
    Fuel system status (Bank1):
    OL or CL or OL DRIVE or OL FAULT or CL FAULT
    CL: Idling after warming up
    1. OL (Open Loop): Has not yet satisfied conditions to go closed loop
    2. CL (Closed Loop): Using heated oxygen sensor as feedback for fuel control
    3. OL DRIVE: Open loop due to driving conditions (fuel enrichment)
    4. OL FAULT: Open loop due to detected system fault
    5. CL FAULT: Closed loop but heated oxygen sensor, which used for fuel control malfunctioning
    O2FT B1 S2
    Short-term fuel trim associated with bank 1 sensor 2:
    Min.: -100 %, Max.: 99.2 %
    -
    -
    AF FT B1 S1
    Short-term fuel trim associated with bank 1 sensor 1:
    Min.: 0, Max.: 1.999
    1. Value less than 1 (0.000 to 0.999) = Lean
    2. Stoichiometric air-fuel ratio=1
    3. Value greater than 1 (1.001 to 1.999) = Rich
    -
    CAT TEMP B1S1
    Catalyst temperature (Bank 1, Sensor 1):
    Min.: -40, Max.: 6,513.5°C
    -
    -
    CAT TEMP B1S2
    Catalyst temperature (Bank 1, Sensor 2):
    Min.: -40, Max.: 6,513.5°C
    -
    -
    INI COOL TEMP
    Initial engine coolant temperature:
    Min.: -40°C, Max.: 140°C
    Engine coolant temperature when engine started
    Service data
    INI INTAKE TEMP
    Initial intake air temperature:
    Min.: -40°C, Max.: 140°C
    Intake air temperature when engine started
    Service data
    INJ VOL
    Injection volume (cylinder 1):
    Min.: 0 ml, Max.: 2.048 ml
    0 to 0.5 ml
    Quantity of fuel injection volume for 10 times
    AIR PMP PRS(A)
    Air pump pressure (absolute):
    Min.: 0 kPa, Max.: 320 kPa
    Atmospheric pressure +2.5 kPa or more: Air pump ON, Air switching valve open
    Close to atmospheric pressure: Air pump OFF, Air switching valve close
    (Click here)
    AIR PMP PLS PRS
    Air pump pulsation pressure:
    Min.: 0 kPa, Max.: 639.9 kPa
    -
    Cumulative pulsation pressure calculated by ECM
    (Click here)
    STARTER SIG
    Starter signal: ON or OFF
    ON: Cranking
    -
    PS SW
    Power steering signal:
    ON or OFF
    ON: Power steering operation
    -
    PS SIGNAL
    Power steering signal:
    ON or OFF
    ON: When steering wheel first turned after battery terminals connected
    This signal status usually ON until battery terminals disconnected
    CTP SW
    Closed throttle position switch:
    ON or OFF
    1. ON: Throttle fully closed
    2. OFF: Throttle open
    -
    A/C SIG
    A/C signal: ON or OFF
    ON: A/C ON
    -
    ELECT LOAD SIG
    Electrical load signal:
    ON or OFF
    ON: Headlights or defogger turned ON
    -
    STOP LIGHT SW
    Stop light switch:
    ON or OFF
    ON: Brake pedal depressed.
    -
    +BM
    Whether or not electronic throttle control system power input:
    ON or OFF
    ON: Idling
    -
    +BM VOLTAGE
    +BM voltage:
    Min.: 0, Max.: 19.92
    10 to 15 V: Idling
    ETCS service data
    BATTERY VOLTAGE
    Battery voltage:
    Min.: 0 V, Max.: 65.535 V
    9 to 14 V: Idling
    -
    ACTUATOR POWER
    Actuator power supply:
    ON or OFF
    ON: Idling
    ETCS service data
    ATM PRESSURE
    Atmospheric pressure:
    Min.: 0 kPa, Max.: 150 kPa
    Equivalent to atmospheric pressure (absolute pressure)
    -
    SECOND AIR VSV
    Secondary air injection system status
    ON: Secondary air injection system operation
    -
    ACT VSV
    A/C cut status for Active Test:
    ON or OFF
    -
    Active Test support data
    EVAP (Purge) VSV
    VSV status for EVAP control:
    ON or OFF
    -
    Active Test support data
    FUEL PUMP / SPD
    Fuel pump/speed status:
    ON or OFF
    -
    Active Test support data
    VVT CTRL B1
    VVT control status:
    ON or OFF
    -
    Active Test support data
    VACUUM PUMP
    Key-off EVAP system pump status:
    ON or OFF
    -
    Active Test support data
    EVAP VENT VAL
    Key-off EVAP system vent valve status:
    ON or OFF
    -
    Active Test support data
    TC/TE1
    TC and TE1 terminals of DLC3:
    ON or OFF
    -
    -
    AI STATUS
    Secondary air injection system operation prohibition:
    OK or NG
    -
    (Click here)
    VVTL AIM ANGL #1
    VVT aim angle (bank 1):
    Min.: 0 %, Max.: 100 %
    0 %: Idling
    VVT duty signal value during intrusive operation
    VVT CHNG ANGL #1
    VVT change angle:
    Min.: 0°FR, Max.: 60°FR
    0 to 5 °FR: Idling
    Displacement angle during intrusive operation
    VVT OCV DUTY B1
    VVT OCV operation duty:
    Min.: 0 %, Max.: 100 %
    0 %: Idling
    Requested duty value for intrusive operation
    FC IDL
    Fuel cut idle:
    ON or OFF
    ON: Fuel cut operation
    FC IDL = "ON" when throttle valve fully closed and engine speed over 2,800 rpm
    FC TAU
    Fuel cut TAU: Fuel cut during very light load:
    ON or OFF
    ON: Fuel cut operation
    Fuel cut being performed under very light load to prevent engine combustion from becoming incomplete
    IGNITION
    Ignition counter:
    Min.: 0, Max.: 400
    0 to 400
    -
    CYL #1, #2, #3, #4
    Misfire ratio of cylinder 1 to 4:
    Min.: 0, Max.: 255
    0 %
    This item displayed in only idling
    CYL ALL
    All cylinders misfire rate:
    Min.: 0, Max.: 255
    0 to 35
    -
    MISFIRE RPM
    Engine RPM for first misfire range:
    Min.: 0 rpm, Max.: 6,375 rpm
    0 rpm: Misfire 0
    -
    MISFIRE LOAD
    Engine load for first misfire range:
    Min.: 0 g/rev, Max.: 3.98 g/rev
    0 g/rev: Misfire 0
    -
    MISFIRE MARGIN
    Misfire monitoring:
    MIn.: -100 %, Max.: 99.22 %
    -100 to 99.2 %
    Misfire detecting margin
    #CODES
    #Codes:
    Min.: 0, Max.: 255
    -
    Number of detected DTCs
    CHECK MODE
    Check mode:
    ON or OFF
    ON: Check mode ON
    (Click here)
    SPD TEST
    Check mode result for vehicle speed sensor:
    COMPL or INCOMPL
    -
    -
    AS TEST
    Check mode result for secondary air injection system:
    COMPL or INCOMPL
    -
    -
    MISFIRE TEST
    Check mode result for misfire monitor:
    COMPL or INCOMPL
    -
    -
    OXS1 TEST
    Check mode result for HO2 sensor :
    COMPL or INCOMPL
    -
    -
    A/F SSR TEST B1
    Check mode result for air-fuel ratio sensor :
    COMPL or INCOMPL
    -
    -
    MIL
    MIL status:
    ON or OFF
    ON: MIL ON
    -
    MIL ON RUN DIST
    MIL ON Run Distance:
    Min.: 0 second,
    Max.: 65,535 seconds
    Distance after DTC detected
    -
    MIL ON RUN TIME
    Running time from MIL ON:
    Min.: 0 minute,
    Max.: 65,535 minutes
    Equivalent to running time after MIL ON
    -
    ENG RUN TIME
    Engine run time:
    Min.: 0 second,
    Max.: 65,535 seconds
    Time after engine start
    Service data
    TIME DTC CLEAR
    Time after DTC cleared:
    Min.: 0 minute,
    Max.: 65,535 minutes
    Equivalent to time after DTCs erased
    -
    DIST DTC CLEAR
    Distance after DTC cleared:
    Min.: 0 km/h, Max.: 65535 km/h
    Equivalent to drive distance after DTCs erased
    -
    WU CYC DTC CLEAR
    Warm-up cycle after DTC cleared:
    Min.: 0, Max.: 255
    -
    Number of warm-up cycles after DTC cleared
    MODEL CODE
    Model code:
    -
    Identifying model code: TRN2###
    ENGINE TYPE
    Engine type:
    -
    Identifying engine type:
    2TR
    CYLINDER NUMBER
    Cylinder number:
    Min.: 0, Max.: 255
    -
    Identifying cylinder number:
    4 or 6
    TRANSMISSION
    Transmission type:
    -
    Identifying transmission type:
    MT, ECT(5AT) or ECT(4AT)
    DESTINATION
    Destination
    -
    Identifying destination:
    A (America)
    MODEL YEAR
    Model year:
    Min.: 0, Max.: 255
    -
    Identifying model year:
    200#
    SYSTEM
    System identification
    -
    Identifying engine system:
    GASLIN (gasoline engine)
    *1: If no idling conditions are specified, transmission gear selector lever should be in the N or P position, and the A/C switch and all accessory switches should be OFF.


ACTIVE TEST

HINT:
Performing an ACTIVE TEST enables components including the relays, VSV (Vacuum Switching Valve), and actuators, to be operated without removing any parts. The ACTIVE TEST can be performed with a intelligent tester. Performing an ACTIVE TEST as the first step of troubleshooting is one method of shortening diagnostic time.
DATA LIST can be displayed during ACTIVE TESTs.

  1. Connect a intelligent tester to the DLC3.

  2. Turn the ignition switch to ON.

  3. Turn the tester ON.

  4. Select the following menu items: DIAGNOSIS / ENHANCED OBD II / ACTIVE TEST.

  5. Perform the ACTIVE TEST by referring to the table below.

    Intelligent Tester Displays
    Test Details
    Control Ranges
    Diagnostic Notes
    INJ VOL
    Change injection volume
    Between -12 % and 25 %
    1. All injectors tested at same time
    2. Perform test at less than 3,000 rpm
    3. Injection volume can be changed in 1 % graduations within control range
    A/F CONTROL
    Change injection volume
    Lower by 12.5 % or increase by 25 %
    1. Perform test at less than 3,000 rpm
    2. A/F CONTROL enables checking and graphing of A/F (Air Fuel Ratio) sensor and Heated Oxygen (HO2) sensor voltage outputs
    3. To conduct test, select following menu items: ACTIVE TEST / A/F CONTROL / USER DATA / AFS B1S1 and O2S B1S2, and press YES and ENTER followed by F4
    EVAP VSV (ALONE)
    Activate EVAP VSV control
    ON/OFF
    -
    VVT CTRL B1
    Turn on and off OCV
    (Oil Control Valve)
    ON/OFF
    1. Engine stalls or idles roughly when OCV turned ON
    2. Normal engine running or idling when OCV off
    A/C CUT SIG
    Control A/C cut signal
    ON/OFF
    -
    FUEL PUMP/SPD
    Activate fuel pump (C/OPN Relay)
    ON/OFF
    -
    TC/TE1
    Turn on and off TC and TE1 connection
    ON/OFF
    1. ON: TC and TE1 connected
    2. OFF: TC and TE1 disconnected
    FC IDL PROHBT
    Prohibit idling fuel cut control
    ON/OFF
    -
    ETCS OPEN SLOW
    Throttle actuator
    ON: throttle valve opens slowly
    Test possible when following conditions met:
    1. Ignition switch ON
    2. Engine does not start
    3. Fully depressing accelerator pedal (APP: 58 degrees or more)
    ETCS CLOSE SLOW
    Throttle actuator
    ON: throttle valve closes slowly
    Same as above
    ETCS OPEN FAST
    Throttle actuator
    ON: throttle valve opens fast
    Same as above
    ETCS CLOSE FAST
    Throttle actuator
    ON: throttle valve closes fast
    Same as above
    FUEL CUT #1
    Cylinder #1 injector fuel cut
    ON/OFF
    Test possible during vehicle stopping and engine idling
    FUEL CUT #2
    Cylinder #2 injector fuel cut
    ON/OFF
    Same as above
    FUEL CUT #3
    Cylinder #3 injector fuel cut
    ON/OFF
    Same as above
    FUEL CUT #4
    Cylinder #4 injector fuel cut
    ON/OFF
    Same as above
    VVT B1
    VVT actuator
    -128 to 127%
    OCV control duty ratio can be set to any value within this range
    100%: Maximum advance
    -100%: Maximum retard
    Engine stalls or idles roughly when VVT actuator is operated at 100 % or more. This test is possible while idling.
    VENT VALVE (ALONE)
    Activate vent valve
    (built into canister pump module)
    ON/OFF
    -
    VCUUM PUMP
    Activate leak detection pump
    (built into canister pump module)
    ON/OFF
    -


SYSTEM CHECK

HINT:
Performing a SYSTEM CHECK enables the system, which consists of multiple actuators, to be operated without removing any parts. In addition, it can show whether or not any DTCs (PENDING CODES) are set, and can detect potential malfunctions in the system. SYSTEM CHECK can be performed with a intelligent tester.

  1. Connect a intelligent tester to the DLC3.

  2. Turn the ignition switch to ON and turn the tester ON.

  3. Select the following menu items: DIAGNOSIS / ENHANCED OBD II / SYSTEM CHECK.

  4. Perform the SYSTEM CHECK by referring to the table below.

  5. Turn the ignition switch to OFF.

    Intelligent Tester Displays
    Test Details
    Recommended Vehicle Conditions
    Diagnostic Notes
    EVAP SYS CHECK
    (AUTOMATIC OPERATION)
    Perform 5 steps in order to operate EVAP key-off monitor automatically
    Fuel temperature 35°C (95°F) or less
    1. If no DTCs in PENDING CODE after performing this test, system functioning normally
    1. Refer to EVAP Inspection Procedure (Click here)
    EVAP SYS CHECK
    (MANUAL OPERATION)
    Perform 5 steps in order to operate EVAP key-off monitor manually
    Fuel temperature 35°C(95°F) or less
    1. Used to detect malfunctioning parts
    1. Refer to EVAP Inspection Procedure (Click here)
    AIR INJ CHECK
    (AUTOMATIC OPERATION)
    Perform secondary air injection system operation automatically
    With warm engine, ignition switch turned OFF once
    1. If no DTCs in PENDING CODE after performing this test, system functioning normally
    2. Refer to inspection procedure for secondary air injection system DTCs
    3. When performing AIR INJ CHECK operation after battery cable has been reconnected, wait for 7 minutes with ignition switch turned to ON or engine running
    4. Turn ignition switch to OFF when SYSTEM CHECK finished
    AIR INJ CHECK
    (MANUAL OPERATION)
    Perform secondary air injection system operation manually Select monitor item 1, 2 or 3
    1. Air pump: ON
      Air switching valve: OPEN
    2. Air pump: OFF
      Air switching valve: CLOSE
    3. Air pump: ON
      Air switching valve: CLOSE
    With warm engine, ignition switch turned OFF once
    1. Used to detect malfunctioning parts
    2. Refer to inspection procedure for secondary air injection system DTCs
    3. When performing AIR INJ CHECK operation after battery cable has been reconnected, wait for 7 minutes with ignition switch turned to ON or engine running
    4. Turn ignition switch to OFF when SYSTEM CHECK finishes