DTC P2440 Secondary Air Injection System Switching Valve Stuck Open Bank1 |
DTC P2441 Secondary Air Injection System Switching Valve Stuck Close Bank1 |
| DTC No. | DTC Detection Conditions | Trouble Areas |
| P2440 | Pressure sensor detects pulsation of exhaust gas despite ECM commanding Air Switching Valve (ASV) to close, while engine running (2 trip detection logic) |
|
| P2441 | Pressure sensor detects no pulsation of exhaust gas despite ECM commanding Air Switching Valve (ASV) to open, while engine running (2 trip detection logic) |
|
| Related DTCs | P2440: Air control valve stuck open P2441: Air control valve stuck closed |
| Required Sensors/Components (Main) | Pressure sensor |
| Required Sensors/Components (Related) | - |
| Frequency of Operation | Once per drive cycle |
| Duration | 7 seconds |
| MIL Operation | 2 driving cycles |
| Sequence of Operation | None |
| Monitor runs whenever following DTCs not present |
|
| Battery voltage | 11 V or more |
| Atmospheric pressure | 45 kPa (337.5 mmHg) or more |
| Time after secondary injection operation begins | 6 seconds or more |
| Secondary air injection pump | ON |
| Secondary air injection switching valve | ON |
| Engine speed | Less than 3,750 rpm |
| Delay time after engine started | 6 seconds or more |
| Pressure sensor malfunction | Not detected |
| Secondary air injection pump | OFF |
| Engine speed | Less than 3,750 rpm |
| Secondary air injection system monitor during secondary air injection ON | Completed |
| Pressure sensor malfunction | Not detected |
| AIR pressure during AIR ON | 2.5 kPa or more and pulse is generated |
| AIR pressure during AIR ON | Less than 2.5 kPa and pulse is generated |
| AIR pressure during AIR ON | 2.5 kPa or more and pulse is not generated |
| AIR pressure during AIR ON | Less than 2.5 kPa and pulse is not generated |
| AIR pressure during AIR OFF | 2.5 kPa or more and pulse is generated |
| AIR pressure during AIR OFF | Less than 2.5 kPa and pulse is generated |
| AIR pressure during AIR OFF | 2.5 kPa or more and pulse is not generated |
| AIR pressure during AIR OFF | Less than 2.5 kPa and pulse is not generated |
| Any of following conditions met: | (a), (b) or (c) |
| (a) Conditions 1 and 6 | Met |
| (b) Conditions 1 and 5 | Met |
| (c) Conditions 2 and 6 | Met |
| Any of following conditions met: | (a), (b) or (c) |
| (a) Conditions 3 and 7 | Met |
| (b) Conditions 3 and 8 | Met |
| (c) Conditions 4 and 8 | Met |


| Air Pump | ON |
| Air Switching Valve | Open |
| Pressure | 2.5 kPa or more |
| Pulsation Detection | Exhaust gas pulsation detected |
| Air Pump | OFF |
| Air Switching Valve | Open |
| Pressure | Less than 2.5 kPa |
| Pulsation Detection | Exhaust gas pulsation detected |
| Air Pump | ON |
| Air Switching Valve | Closed |
| Pressure | 2.5 kPa or more |
| Pulsation Detection | Slight pulsation detected |
| Air Pump | OFF |
| Air Switching Valve | Open |
| Pressure | Less than 2.5 kPa |
| Pulsation Detection | Exhaust gas pulsation detected |
| Detected Conditions while AIR operating: Air pump ON, ASV Open | Detected Conditions while AIR not operating: Air pump OFF, ASV Closed | ECM Determination | DTCs Output |
| Case 1 | Case 4 | Normal | - |
| Case 1 | Case 2 | ASV stuck open | P2440 |
| Case 1 | Case 3 | Air pump stuck ON | P2444 |
| Case 2 | Case 4 | Air pump stuck OFF | P2445 |
| Case 3 | Case 4 | ASV stuck closed | P2441 |
| Case 1 | Case 1 | ASV stuck open and Air pump stuck ON | P2440 and P2444 |
| Case 2 | Case 2 | ASV stuck open and Air pump stuck OFF | P2440 and P2445 |
| Case 3 | Case 3 | ASV stuck closed and Air pump stuck ON | P2441 and P2444 |
| Case 4 | Case 4 | ASV stuck closed and Air pump stuck OFF | P2441 and P2445 |
![]() |
| Intelligent Tester Operations | AIR PUMP | ASV | PRESSURE *1
| PULSATION *2
|
| AP: ON, ASV: OPEN | ON | OPEN | 2.5 kPa or more | 11.25 kPa or more |
| AP: OFF, ASV: CLOSE | OFF | CLOSE | Less than 2.5 kPa | Less than 11.25 kPa |
![]() |
| 1.CHECK ANY OTHER DTCS OUTPUT (IN ADDITION TO SECONDARY AIR INJECTION SYSTEM DTCS) |
Connect an intelligent tester to the DLC3.
Turn the ignition switch to ON and turn the tester ON.
Select the following menu items: DIAGNOSIS / ENHANCED OBD II / DTC INFO / CURRENT CODES.
Read DTCs.
| Display (DTC Output) | Proceed To |
| P2440 and/or P2441 | A |
| P2440 and/or P2441, and P0412 | B |
| P2440 and/or P2441, and other DTCs (except P0412) | C |
|
| ||||
|
| ||||
| A | |
| 2.PERFORM ACTIVE TEST USING INTELLIGENT TESTER |
![]() |
Visual check
Start the engine and warm it up.
Turn the ignition switch to OFF.
Disconnect the No. 1 air injection system hose.
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON and turn the tester ON.
Select the following menu items:
DIAGNOSIS / ENHANCED OBD II / SYSTEM CHECK / AIR INJ CHECK / MANUAL OPERATION / AP: ON, ASV: OPEN.
Start the engine.
Perform the AIR system intrusive operation while the engine is idling.
Place your hand near the air switching valve port and check that the exhaust gas pressure pulsates when the ASV is turned ON.
Select the following menu items: DIAGNOSIS / ENHANCED OBD II / SYSTEM CHECK / AIR INJ CHECK / MANUAL OPERATION / AP: ON, ASV: CLOSE.
Check that the exhaust gas does not pulsate when the ASV is turned OFF.
![]() |
Turn the ignition switch to OFF.
| Air Pump Operations | ASV Operations | Exhaust Gas Pulsation |
| ON | OFF | Not detected |
| ON | ON | Detected |
Reconnect the No. 1 air injection system hose.
Reconnect the air cleaner hose.
Other inspection method:
The ASV operation can be confirmed by checking the cumulative pressure pulsation* provided in the SYSTEM CHECK.
Perform SYSTEM CHECK operation under MANUAL OPERATION.
*: The exhaust pulsation value is calculated in the ECM. If the calculated value exceeds a certain level, the ECM determines that the exhaust pulsation is in the AIR system.
![]() |
Start the engine and warm it up.
Turn the ignition switch to OFF.
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON and turn the tester ON.
Select the following menu items: DIAGNOSIS / ENHANCED OBD II / SYSTEM CHECK / AIR INJ CHECK / MANUAL OPERATION / AP: ON, ASV OPEN and AP: OFF, ASV: CLOSE.
Start the engine after the tester initialization is finished.
Perform the AIR system intrusive operation while the engine is idling.
Check that the air-fuel ratio and pressure in the secondary air injection system passage (PULSATION) displayed on the tester, indicate the conditions shown in the table below.
Turn the ignition switch to OFF.
| AIR System Operations | Pulsation Conditions (ECM Calculation) | Air-Fuel Ratio (Reference) |
| AP: ON, ASV: OPEN | 11.25 kPa or more | 18 or more |
| AP: OFF, ASV: CLOSE | Less than 11.25 kPa | Approximately 14.5 (around stoichiometric air-fuel ratio) |
|
| ||||
| NG | |
| 3.INSPECT NO.4 INTAKE PIPE (BLOCKAGES AND LEAKAGES) |
![]() |
Check that the No. 4 intake pipe is securely connected to both the exhaust manifold and the ASV.
Inspect the No. 4 intake pipe for blockages and damage.
|
| ||||
| OK | |
| 4.INSPECT AIR SWITCHING VALVE ASSEMBLY (AIR SWITCHING VALVE OPERATION) |
![]() |
Check the resistance.
Using an ohmmeter, measure the resistance between the terminals.
| Tester Connections | Specified Conditions |
| A10-1 - A10-2 | 3 to 10 Ω at 20°C (68°F) |
![]() |
Check the operation.
Check that air does not flow from the ports.
![]() |
Apply the battery positive voltage across the terminals.
Check that air flows from the ports.
If the operation is not as specified, replace the ASV.
|
| ||||
| OK | |
| 5.INSPECT AIR INJECTION CONTROL DRIVER (POWER SOURCE OF AIR INJECTION CONTROL DRIVER) |
![]() |
Disconnect the A6 and A7 AID connectors.
Turn the ignition switch to ON.
Measure the voltage between the terminals of the AID connector.
| Tester Connections | Specified Conditions |
| BATT (A7-5) - Body ground | 9 to 14 V (near battery voltage) |
| +B (A6-1) - Body ground | 9 to 14 V (near battery voltage) |
Check the resistance.
| Tester Connections | Specified Conditions |
| E (A7-1) - Body ground | Below 1 Ω |
Reconnect the AID connectors.
|
| ||||
| OK | |
| 6.PERFORM ACTIVE TEST USING INTELLIGENT TESTER |
![]() |
Start the engine and warm it up.
Turn the ignition switch to OFF.
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON and turn the tester ON.
Select the following menu items: DIAGNOSIS / ENHANCED OBD II / SYSTEM CHECK / AIR INJ CHECK / MANUAL OPERATION / AP: ON, ASV: OPEN and AP: OFF, ASV: CLOSE.
Start the engine after the tester initialization is finished.
Operate the AIR system using the SYSTEM CHECK function and measure the voltage between the terminals of the ECM connector.
Turn the ignition switch to OFF.
| Intelligent Tester Operations | Voltmeter Connections | Specified Conditions |
| AP: ON, ASV: OPEN | AIRP (E4-11) - E1 (E4-3) | 3.5 to 7.5 V |
| AP: OFF, ASV: CLOSE | AIRP (E4-11) - E1 (E4-3) | 10 V or more |
| AP: ON, ASV: OPEN | AIRV (E4-24) - E1 (E4-3) | 3.5 to 7.5 V |
| AP: OFF, ASV: CLOSE | AIRV (E4-24) - E1 (E4-3) | 10 V or more |
|
| ||||
| OK | |
| 7.REPLACE AIR INJECTION CONTROL DRIVER |
| NEXT | |
| 8.CHECK WHETHER DTC OUTPUT RECURS (DTC P2440 AND/OR P2441) |
Start the engine and warm it up.
Turn the ignition switch to OFF.
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON and turn the tester ON.
Clear DTCs (where set) (Click here).
Select the following menu items:
DIAGNOSIS / ENHANCED OBD II / SYSTEM CHECK / AIR INJ CHECK / AUTOMATIC OPERATION.
Start the engine after the tester initialization is finished.
Perform the SYSTEM CHECK operation by pressing ENTER.
After operating the AIR system, press the ENTER button to confirm the AIR system pending codes.
Check PENDING DTCs.
Turn the ignition switch to OFF.
| NEXT | ||
| ||
| 9.INSPECT VACUUM HOSES (AIR SWITCHING VALVE - PRESSURE SENSOR) |
|
| ||||
| OK | |
| 10.INSPECT ECM (AIP VOLTAGE) |
![]() |
Connect a pressure gauge to the air pressure sensor as shown in the illustration.
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON and turn the tester ON.
Select the following menu items: DIAGNOSIS / ENHANCED OBD ll / DATA LIST / AIR PMP PRS(A).
Check that the pressure displayed on the tester fluctuates when applying pressure to the pressure sensor with the pressure gauge.
|
| ||||
| OK | ||
| ||
| 11.CHECK HARNESS AND CONNECTOR (ECM - AIR INJECTION CONTROL DRIVER) |
![]() |
Disconnect the E4 ECM connector.
Disconnect the A7 AID connector.
Check the resistance.
| Tester Connections | Specified Conditions |
| AIRV (E4-24) - EIV (A7-3) | Below 1 Ω |
Reconnect the ECM and AID connectors.
|
| ||||
| OK | ||
| ||