Home › BRAKE › BRAKE CONTROL › VEHICLE STABILITY CONTROL SYSTEM

VEHICLE STABILITY CONTROL SYSTEM > Brake Warning Light Remains ON

for Preparation Click here


DESCRIPTION

The BRAKE warning light lights up when the brake fluid is insufficient, the parking brake is applied or the EBD is defective.

WIRING DIAGRAM


C124784E01


INSPECTION PROCEDURE

NOTICE:
When replacing the master cylinder solenoid, perform zero point calibration (Click here).

1.CHECK DTC
  1. Check the DTCs (Click here).

    Result
    Proceed to
    DTC not output
    A
    DTC output
    B



B
REPAIR CIRCUITS INDICATED BY OUTPUT DTCS
A


2.CHECK BRAKE FLUID LEVEL
  1. Check the amount of brake fluid in the brake reservoir.

    OK:
    Brake fluid level is correct.



NG
ADD BRAKE FLUID
OK


3.CHECK SKID CONTROL ECU CONNECTOR
  1. Check whether skid control ECU connector is connected securely.

    OK:
    The skid control ECU connector is connected securely.



NG
CONNECT CONNECTOR CORRECTLY
OK


4.INSPECT BATTERY
  1. Check the battery voltage.

    Standard:
    11 to 14 V



NG
INSPECT CHARGING SYSTEM
OK


5.INSPECT SKID CONTROL ECU (IG1 TERMINAL VOLTAGE)


    C121700E02
  1. Disconnect the skid control ECU connector.

  1. Turn the ignition switch to the ON position.

  1. Measure the voltage.

    Standard:
    Tester Connection
    Specified Condition
    S1-46 (IG1) - Body ground
    10 to 14 V

  1. Turn the ignition switch to OFF.

  1. Reconnect the skid control ECU connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (IG1 CIRCUIT)
OK


6.CHECK HARNESS AND CONNECTOR (GND TERMINAL CONTINUITY)


    C124799E01
  1. Disconnect the skid control ECU connectors.

  1. Measure the resistance.

    Standard:
    Tester Connection
    Specified Condition
    S1-1 (GND1) - Body ground
    Below 1 Ω
    S1-32 (GND2) - Body ground
    Below 1 Ω
    S2-4 (GND3) - Body ground
    Below 1 Ω

  1. Reconnect the skid control ECU connectors.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (GND CIRCUIT)
OK


7.INSPECT BRAKE FLUID LEVEL WARNING SWITCH


    F052341E01
  1. Disconnect the brake fluid level warning switch connector.

  1. Measure the resistance.

    Standard:
    Tester Connection
    Condition
    Specified Condition
    B2-1 - B2-2
    Float UP
    10 kΩ or higher
    B2-1 - B2-2
    Float DOWN
    Below 1 Ω

  1. Reconnect the brake fluid level warning switch connector.

HINT:
If there is no problem after finishing the above check, adjust the brake fluid level to the maximum level.



NG
REPLACE BRAKE MASTER CYLINDER RESERVOIR SUB-ASSEMBLY
OK


8.CHECK HARNESS AND CONNECTOR (SKID CONTROL ECU - BRAKE FLUID LEVEL WARNING SWITCH)


    F051748E02
  1. Disconnect the skid control ECU connector.

  1. Disconnect the brake fluid level warning switch connector.

  1. Measure the resistance.

    Standard:
    Tester Connection
    Specified Condition
    S1-41 (LBL) - B2-2
    Below 1 Ω

  1. Measure the resistance.

    Standard:
    Tester Connection
    Specified Condition
    S1-41 - Body ground
    10 kΩ or higher

  1. Reconnect the brake fluid level warning switch connector.

  1. Reconnect the skid control ECU connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


9.INSPECT PARKING BRAKE SWITCH ASSEMBLY


    F052447E01
  1. Disconnect the parking brake switch connector.

  1. Measure the resistance.

    Standard:
    Tester Connection
    Switch Condition
    Specified Condition
    P6-1 - Body ground
    Released
    Below 1 Ω
    P6-1 - Body ground
    Pushed in
    10 kΩ or higher

  1. Reconnect the parking brake switch connector.



NG
REPLACE PARKING BRAKE SWITCH ASSEMBLY
OK


10.CHECK HARNESS AND CONNECTOR (SKID CONTROL ECU - PARKING BRAKE SWITCH)


    C124797E01
  1. Disconnect the skid control ECU.

  1. Disconnect the parking brake switch connector.

  1. Measure the resistance.

    Standard:
    Tester Connection
    Specified Condition
    S1-28 (PKB) - P6-1
    Below 1 Ω
    S1-28 (PKB) - Body ground
    10 kΩ or higher

  1. Reconnect the parking brake switch connector.

  1. Reconnect the skid control ECU.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


11.CHECK HARNESS AND CONNECTOR (SKID CONTROL ECU - COMBINATION METER)


    F051819E01
  1. Disconnect the skid control ECU connector.

  1. Disconnect the combination meter connector.

  1. Measure the resistance.

    Standard:
    Tester Connection
    Specified Condition
    S2-3 (BRL) - C10-10
    Below 1 Ω

  1. Measure the resistance.

    Standard:
    Tester Connection
    Specified Condition
    S2-3 (BRL) - Body ground
    10 kΩ or higher

  1. Reconnect the combination meter connector.

  1. Reconnect the skid control ECU connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


12.INSPECT COMBINATION METER ASSEMBLY
  1. Check the combination meter system (Click here).

    OK:
    Combination meter is normal.



NG
REPLACE COMBINATION METER ASSEMBLY
OK

REPLACE MASTER CYLINDER SOLENOID