Home › ENGINE · 1GR-FE › ENGINE CONTROL SYSTEM › SFI SYSTEM

DTC    P0327    Knock Sensor 1 Circuit Low Input (Bank 1 or Single Sensor)

DTC    P0328    Knock Sensor 1 Circuit High Input (Bank 1 or Single Sensor)

DTC    P0332    Knock Sensor 2 Circuit Low Input (Bank 2)

DTC    P0333    Knock Sensor 2 Circuit High Input (Bank 2)

for Preparation Click here


DESCRIPTION

A flat type knock sensor (non-resonant type) has a structure that can detect vibrations over a wide band of frequencies: between approximately 5 kHz and 15 kHz.
Knock sensors are fitted onto the engine block to detect engine knocking.
The knock sensor contains a piezoelectric element which generates a voltage when it becomes deformed.
The voltage is generated when the engine block vibrates due to knocking. Any occurrence of engine knocking can be suppressed by delaying the ignition timing.

DTC No.
DTC Detection Condition
Trouble Area
P0327
P0332
Output voltage of knock sensor less than 0.5 V for 1 second
(1 trip detection logic)
  1. Short in knock sensor circuit
  2. Knock sensor
  3. ECM
P0328
P0333
Output voltage of knock sensor more than 4.5 V for 1 second
(1 trip detection logic)
  1. Open in knock sensor circuit
  2. Knock sensor
  3. ECM

HINT:
When any of DTCs P0327, P0328, P0332 and P0333 are stored, the ECM enters fail-safe mode. During fail- safe mode, the ignition timing is delayed to its maximum retardation. Fail-safe mode continues until the ignition switch is turned off.


  1. A085286E91
  2. Inspection using an oscilloscope
    The correct waveform is as shown.
    Item
    Content
    Terminal
    KNK1 - EKNK
    or
    KNK2 - EKN2
    Equipment Setting
    1 V/DIV, 1 ms/DIV
    Condition
    Keep engine speed at 4000 rpm with
    warm engine

MONITOR DESCRIPTION

If the output voltage transmitted by the knock sensor remains low or high for 1 second, the ECM interprets this as a malfunction in the sensor circuit, and stores a DTC.
The monitor for DTCs P0327 and P0328 begins to run when 5 seconds have elapsed since the engine was started.
If the malfunction is not repaired successfully, any of DTC P0327, P0328, P0332 or P0333 is stored 5 seconds after the engine is next started.

MONITOR STRATEGY


Related DTCs
P0327: Knock sensor (Bank 1) open/short (Low voltage)
P0328: Knock sensor (Bank 1) open/short (High voltage)
P0332: Knock sensor (Bank 2) open/short (Low voltage)
P0333: Knock sensor (Bank 2) open/short (High voltage)
Required Sensors/Components (Main)
Knock sensor (Bank 1, 2)
Required Sensors/Components (Related)
-
Frequency of Operation
Continuous
Duration
1 second
MIL Operation
Immediate
Sequence of Operation
None

TYPICAL ENABLING CONDITIONS


Monitor runs whenever following DTCs not stored
None
Battery voltage
10.5 V or more
Time after engine start
5 seconds or more
Ignition switch
ON
Starter
Off

TYPICAL MALFUNCTION THRESHOLDS


Knock Sensor Range Check (Low voltage) P0327 and P0332 
Knock sensor voltage
Less than 0.5 V

Knock Sensor Range Check (High voltage) P0328 and P0333 
Knock sensor voltage
More than 4.5 V

CONFIRMATION DRIVING PATTERN

  1. Connect the Techstream to the DLC3.
  2. Turn the ignition switch to ON and turn the Techstream on.
  3. Clear DTCs (even if no DTCs are stored, perform the clear DTC operation).
  4. Turn the ignition switch off and wait for at least 30 seconds.
  5. Turn the ignition switch to ON and turn the Techstream on.
  6. Start the engine and wait 5 minutes.
  7. Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.
  8. Read pending DTCs.

    HINT:
    1. If a pending DTC is output, the system is malfunctioning.
    2. If a pending DTC is not output, perform the following procedure.

  9. Enter the following menus: Powertrain / Engine and ECT / Utility / All Readiness.
  10. Input the DTC: P0327, P0328, P0332, P0333.
  11. Check the DTC judgment result.

    Techstream Display
    Description
    NORMAL
    1. DTC judgment completed
    2. System normal
    ABNORMAL
    1. DTC judgment completed
    2. System abnormal
    INCOMPLETE
    1. DTC judgment not completed
    2. Perform driving pattern after confirming DTC enabling conditions
    N/A
    1. Unable to perform DTC judgment
    2. Number of DTCs which do not fulfill DTC preconditions has reached ECU's memory limit

    HINT:
    1. If the judgment result shows NORMAL, the system is normal.
    2. If the judgment result shows ABNORMAL, the system has a malfunction.
    3. If the judgment result shows INCOMPLETE or N/A, idle the engine for 5 minutes and check the DTC judgment result again.

  12. If no pending DTC is output, perform a universal trip and check for permanent DTCs (Click here).

    HINT:
    1. If a permanent DTC is output, the system is malfunctioning.
    2. If no permanent DTC is output, the system is normal.


WIRING DIAGRAM


A264264E03


A264264E01


INSPECTION PROCEDURE

HINT:
  1. DTCs P0327 and P0328 are for the bank 1 knock sensor circuit.
  2. DTCs P0332 and P0333 are for the bank 2 knock sensor circuit.
  3. Bank 1 refers to the bank that includes the No. 1 cylinder*.
    *: The No. 1 cylinder is the cylinder which is farthest from the transmission.
  4. Bank 2 refers to the bank that does not include the No. 1 cylinder.
  5. Read freeze frame data using the Techstream. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air fuel ratio was lean or rich, and other data from the time the malfunction occurred.

1.INSPECT KNOCK SENSOR
C189656E08
  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    E10-11 (KNK1) - E10-12 (EKNK)
    20°C (68°F)
    120 to 280 kΩ
    E10-5 (KNK2) - E10-6 (EKN2)
    20°C (68°F)
    120 to 288 kΩ

    Text in Illustration 
    *a
    Rear view of wire harness connector
    (to ECM)



NG
Go to step 3
OK


2.INSPECT ECM
A239777E33
  1. Turn the ignition switch to ON.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    E10-11 (KNK1) - E10-12 (EKNK)
    Ignition switch ON
    4.5 to 5.5 V
    E10-5 (KNK2) - E10-6 (EKN2)
    Ignition switch ON
    4.5 to 5.5 V

    Text in Illustration 
    *a
    Component with harness connected
    (ECM)



NG
REPLACE ECM (Click here)
OK

CHECK FOR INTERMITTENT PROBLEMS (Click here)  

3.CHECK HARNESS AND CONNECTOR (ECM - KNOCK SENSOR)
  1. Disconnect the ECM connector.

  1. Disconnect the knock sensor connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:

    w/ Secondary Air Injection System 
    Tester Connection
    Condition
    Specified Condition
    E10-11 (KNK1) - K4-2
    Always
    Below 1 Ω
    E10-12 (EKNK) - K4-1
    Always
    Below 1 Ω
    E10-5 (KNK2) - K2-2
    Always
    Below 1 Ω
    E10-6 (EKN2) - K2-1
    Always
    Below 1 Ω
    E10-11 (KNK1) or K4-2 - Body ground
    Always
    10 kΩ or higher
    E10-12 (EKNK) or K4-1 - Body ground
    Always
    10 kΩ or higher
    E10-5 (KNK2) or K2-2 - Body ground
    Always
    10 kΩ or higher
    E10-6 (EKN2) or K2-1 - Body ground
    Always
    10 kΩ or higher


    Standard Resistance:

    w/o Secondary Air Injection System 
    Tester Connection
    Condition
    Specified Condition
    E10-11 (KNK1) - K1-2
    Always
    Below 1 Ω
    E10-12 (EKNK) - K1-1
    Always
    Below 1 Ω
    E10-5 (KNK2) - K2-2
    Always
    Below 1 Ω
    E10-6 (EKN2) - K2-1
    Always
    Below 1 Ω
    E10-11 (KNK1) or K1-2 - Body ground
    Always
    10 kΩ or higher
    E10-12 (EKNK) or K1-1 - Body ground
    Always
    10 kΩ or higher
    E10-5 (KNK2) or K2-2 - Body ground
    Always
    10 kΩ or higher
    E10-6 (EKN2) or K2-1 - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE KNOCK SENSOR