DTC P0455 Evaporative Emission Control System Leak Detected (Gross Leak) |
DTC P0456 Evaporative Emission Control System Leak Detected (Very Small Leak) |
| DTC No. | Monitoring Item | Malfunction Detection Condition | Trouble Area | Detection Timing | Detection Logic |
| P0455 | EVAP gross leak | Leak detection pump creates negative pressure (vacuum) in EVAP system and EVAP system pressure is measured. Reference pressure is measured at start and end of leak check. If stabilized pressure is higher than [second reference pressure x 0.2], ECM determines that EVAP system has a large leak. |
| While ignition switch off | 2 trip |
| P0456 | EVAP small leak | Leak detection pump creates negative pressure (vacuum) in EVAP system and EVAP system pressure is measured. Reference pressure measured at start and end of leak check. If stabilized pressure is higher than second reference pressure, ECM determines that EVAP system has a small leak. |
| Sequence | Operation | Description | Duration |
| - | ECM activation | Activated by soak timer 5, 7 or 9.5 hours after ignition switch turned off. | - |
| A | Atmospheric pressure measurement | Vent valve is turned off (vent) and EVAP system pressure is measured by ECM in order to register atmospheric pressure. If pressure in EVAP system is not between 70 kPa(abs) and 110 kPa(abs) [525 mmHg(abs) and 825 mmHg(abs)], ECM cancels EVAP system monitor. | 60 seconds |
| B | First reference pressure measurement | In order to determine reference pressure, leak detection pump creates negative pressure (vacuum) through reference orifice and then ECM checks if leak detection pump and vent valve operate normally. | 60 seconds |
| C | EVAP system pressure measurement | Vent valve is turned on (closed) to shut EVAP system. Negative pressure (vacuum) is created in EVAP system, and EVAP system pressure is then measured. Write down measured value as it will be used in leak check. If EVAP pressure does not stabilize within 15 minutes, ECM cancels EVAP system monitor. | 15 minutes* |
| D | Purge VSV monitor | Purge VSV is opened and then EVAP system pressure is measured by ECM. Large increase indicates normal. | 10 seconds |
| E | Second reference pressure measurement | After second reference pressure measurement, leak check is performed by comparing first and second reference pressure. If stabilized system pressure is higher than second reference pressure, ECM determines that EVAP system is leaking. | 60 seconds |
| - | Final check | Atmospheric pressure is measured and then monitoring result is recorded by ECM. | - |

| *1 | Purge VSV: OFF (closed) | *2 | Purge VSV: ON (open) |
| *3 | Vent Valve: OFF (vent) | *4 | Vent Valve: ON (closed) |
| *5 | Leak Detection Pump: OFF | *6 | Leak Detection Pump: ON |
| *7 | Reference Orifice (0.02 inch) | *8 | Canister Pressure Sensor |
| *9 | Canister | *10 | Fuel Tank |
| *11 | Canister Pump Module | *12 | Canister Filter |
| *a | Operation A: Atmospheric Pressure Measurement | *b | Operation B, E: Reference Pressure Measurement |
| *c | Operation C: EVAP System Pressure Measurement | *d | Operation D: Purge VSV Monitor |
| *e | Atmospheric Pressure | *f | Negative Pressure |

| Required Sensors/Components | Purge VSV and canister pump module |
| Frequency of Operation | Once per driving cycle |
| Duration | Within 15 minutes (varies with amount of fuel in tank) |
| MIL Operation | 2 driving cycles |
| Sequence of Operation | None |
| Monitor runs whenever following DTCs not present | None |
| Atmospheric pressure | 70 to 110 kPa(abs) [525 to 825 mmHg(abs)] |
| Battery voltage | 10.5 V or higher |
| Vehicle speed | Less than 4 km/h (2.5 mph) |
| Ignition switch | OFF |
| Time after key-off | 5, 7 or 9.5 hours |
| Canister pressure sensor malfunction (P0452, P0453) | Not detected |
| Purge VSV | Not operated by scan tool |
| Vent valve | Not operated by scan tool |
| Leak detection pump | Not operated by scan tool |
| Both of following conditions met before-key off | Conditions 1 and 2 |
| 1. Duration that vehicle has been driven | 5 minutes or more |
| 2. EVAP purge operation | Performed |
| Engine coolant temperature | 4.4 to 35°C (40 to 95°F) |
| Intake air temperature | 4.4 to 35°C (40 to 95°F) |
| EVAP pressure when vacuum introduction complete | Higher than [reference pressure x 0.2] |
| EVAP pressure when vacuum introduction complete | Between reference pressure and [reference pressure x 0.2] |
| Techstream Display | Description |
| NORMAL |
|
| ABNORMAL |
|
| INCOMPLETE |
|
| N/A |
|