Home › TRANSMISSION · A340F AUTOMATIC TRANSMISSION › AUTOMATIC TRANSMISSION SYSTEM

DTC    P2742    Transmission Fluid Temperature Sensor "B" Circuit Low Input

DTC    P2743    Transmission Fluid Temperature Sensor "B" Circuit High Input

for Preparation Click here


DESCRIPTION

The ATF (Automatic Transmission Fluid) temperature sensor converts the fluid temperature into a resistance value which is input into the ECM.
The ECM applies a voltage to the temperature sensor through ECM terminal THO1.
The sensor resistance changes with the transmission fluid temperature. As the temperature becomes higher, the sensor resistance decreases.
One terminal of the sensor is grounded so that the sensor resistance and the voltage decrease as the temperature becomes higher.
The ECM calculates the fluid temperature based on the voltage signal.

DTC No.
DTC Detection Condition
Trouble Area
P2742
No. 1 ATF temperature sensor resistance is less than 79 Ω for 0.5 seconds or more (1-trip detection logic)
  1. Wire harness or connector
  2. Transmission wire (No. 1 ATF temperature sensor)
  3. ECM
P2743
No. 1 ATF temperature sensor resistance is more than 156 kΩ for 0.5 seconds or more, or either of the following conditions is met (1-trip detection logic):
  1. Wire harness or connector
  2. Transmission wire (No. 1 ATF temperature sensor)
  3. ECM
Condition (A):
7 minutes and 13 seconds or more have elapsed after the engine start when engine coolant temperature or intake air temperature is -29.375°C (-20.875°F) or less.
Condition (B):
10 seconds or more have elapsed after the engine start when engine coolant temperature and intake air temperature are more than -29.375°C (-20.875°F).

MONITOR DESCRIPTION

The Automatic Transmission Fluid (ATF) temperature sensor converts the ATF temperature to an electrical resistance value. Based on the resistance, the ECM determines the ATF temperature, and detects any open or short malfunctions in the ATF temperature circuit. If the resistance of the ATF temperature is less than 79 Ω or more than 156 kΩ, the ECM interprets this as a fault in the ATF temperature sensor or its wiring. The ECM turns on the MIL and stores a DTC.

HINT:
The ATF temperature can be checked on the Techstream display.


MONITOR STRATEGY


Related DTCs
P2742: ATF temperature sensor/Range check (Low resistance)
P2743: ATF temperature sensor/Range check (High resistance)
Required sensors/Components
ATF temperature sensor
Frequency of operation
Continuous
Duration
0.5 seconds
MIL operation
Immediate
Sequence of operation
None

TYPICAL ENABLING CONDITIONS


All: 
Battery voltage
8 V or more
Ignition switch
ON
Starter
OFF

P2742: Range check (Low resistance) 
Monitor runs whenever following DTCs not present.
None

P2743: Range check (High resistance) 
One of the following conditions is met: Condition (A) or (B)

Condition (A) 
The monitor will run whenever the following DTCs are not present
P0115, P0117, P0118 (ECT sensor circuit)
P0110, P0112, P0113 (IAT sensor circuit)
Engine coolant temperature or intake air temperature at engine start
-29.375°C (-20.875°F) or less
Time after engine start
7 minutes and 13 seconds or more
ECT sensor circuit fail (P0115, P0117, P0118)
Not detected
IAT sensor circuit fail (P0110, P0112, P0113)
Not detected

Condition (B) 
The monitor will run whenever the following DTCs are not present
P0115, P0117, P0118 (ECT sensor circuit)
P0110, P0112, P0113 (IAT sensor circuit)
Engine coolant temperature or intake air temperature at engine start
More than -29.375°C (-20.875°F)
Time after engine start
10 seconds or more
ECT sensor circuit fail (P0115, P0117, P0118)
Not detected
IAT sensor circuit fail (P0110, P0112, P0113)
Not detected

TYPICAL MALFUNCTION THRESHOLDS


P2742: Range check (Low resistance) 
ATF temperature sensor resistance
(No. 1 ATF temperature sensor output temperature)
Less than 79 Ω
(Higher than 164°C (327.2°F))

P2743: Range check (High resistance) 
ATF temperature sensor resistance
(No. 1 ATF temperature sensor output temperature)
More than 156 kΩ
(Less than -48°C (-54.4°F))

COMPONENT OPERATING RANGE


ATF temperature sensor resistance
(No. 1 ATF temperature sensor output temperature)
79 Ω to 156 kΩ
(-48 to 164°C (-54.4 to 327.2°F))

WIRING DIAGRAM


C186139E08


INSPECTION PROCEDURE

NOTICE:
Perform the universal trip to clear permanent DTCs (Click here).

HINT:
Using the Techstream to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.

NOTICE:
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.

  1. Warm up the engine.
  2. Turn the ignition switch off.
  3. Connect the Techstream to the DLC3.
  4. Turn the ignition switch to ON.
  5. Turn the Techstream on.
  6. Enter the following menus: Powertrain / Engine and ECT / Data List.
  7. According to the display on the Techstream, read the Data List.

    Engine and ECT 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    A/T Oil Temperature 1
    No. 1 ATF temperature sensor value/
    Min.: -40°C (-40°F)
    Max.: 215°C (419°F)
    1. Approximately 80°C (176°F): After stall test
    2. Equal to ambient temperature when engine cold
    If the value is -40°C (-40°F) or 215°C (419°F), the No. 1 ATF temperature sensor circuit is open or shorted.

    HINT:
    When DTC P2742 is output and the Techstream output is 150°C (302°F) or higher, there is a short circuit.
    When DTC P2743 is output and the Techstream output is -40°C (-40°F), there is an open circuit.
    Check the temperature displayed on the Techstream in order to check if a malfunction exists.


    Temperature Displayed
    Malfunction
    -40°C (-40°F)
    Open circuit
    150°C (302°F) or higher
    Short circuit
1.INSPECT TRANSMISSION WIRE (NO. 1 ATF TEMPERATURE SENSOR)


    C214964E01
  1. Disconnect the transmission wire connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 (OT2+) - 5 (OT2-)
    Always
    79 Ω to 156 kΩ
    1 (OT2+) - Body ground
    Always
    10 kΩ or higher
    5 (OT2-) - Body ground
    Always
    10 kΩ or higher

    HINT:
    If the resistance is out of the specified range at any of the ATF temperatures shown in the table below, the driveability of the vehicle may decrease.

    Standard Resistance:
    ATF Temperature
    Specified Condition
    10°C (50°F)
    5 to 8 kΩ
    25°C (77°F)
    2.5 to 4.5 kΩ
    110°C (230°F)
    0.22 to 0.28 kΩ

Text in Illustration 
*a
Component without harness connected
(Transmission Wire)


NG
REPAIR OR REPLACE TRANSMISSION WIRE (NO. 1 ATF TEMPERATURE SENSOR) (Click here)
OK


2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)


    C223990E01
  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    E5-24 (THO1) - E4-28(E2)
    Always
    79 Ω to 156 kΩ
    E5-24 (THO1) - Body ground
    Always
    10 kΩ or higher
    E5-28 (E2) - Body ground
    Always
    10 kΩ or higher

    Text in Illustration 
    *a
    Rear view of wire harness connector
    (to ECM)



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (Click here)