Home › TRANSMISSION · A340F AUTOMATIC TRANSMISSION › AUTOMATIC TRANSMISSION SYSTEM

DTC    P2759    Torque Converter Clutch Pressure Control Solenoid Control Circuit Electrical (Shift Solenoid Valve SLU)

for Preparation Click here


DESCRIPTION

Refer to DTC P2757 .

DTC No.
DTC Detection Condition
Trouble Area
P2759
Open or short is detected in shift solenoid valve SLU circuit for 1 second or more while driving. (1 trip detection logic)
  1. Wire harness or connector
  2. Transmission wire
  3. Shift solenoid valve SLU
  4. ECM

MONITOR DESCRIPTION

When an open or short is detected in the shift solenoid valve (SLU) circuit, the ECM determines that there is a malfunction. The ECM turns on the MIL and stores this DTC.

MONITOR STRATEGY


Related DTCs
P2759: Shift solenoid valve SLU/Range check
Required sensors/Components
Shift solenoid valve SLU
Frequency of operation
Continuous
Duration
1 second
MIL operation
Immediate
Sequence of operation
None

TYPICAL ENABLING CONDITIONS


All 
Monitor runs whenever following DTCs not present.
None

Malfunction (A) 
Solenoid current cut status
Not cut
Battery voltage
11 V or more
Ignition switch
ON
Starter
OFF

Malfunction (B) 
Battery voltage
8 V or more
Ignition switch
ON
Starter
OFF

TYPICAL MALFUNCTION THRESHOLDS


Malfunction (A) 
Solenoid status (SLU) from hybrid IC
Fail

Malfunction (B) 
Hybrid IC status
Fail

WIRING DIAGRAM


C186142E13


INSPECTION PROCEDURE

NOTICE:
Perform the universal trip to clear permanent DTCs (Click here).

1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLU)


    C214964E05
  1. Disconnect the transmission wire connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    3 (SLU+) - 7 (SLU-)
    20°C (68°F)
    5.1 to 5.5 Ω
    3 (SLU+) - Body ground
    Always
    10 kΩ or higher
    7 (SLU-) - Body ground
    Always
    10 kΩ or higher

    Text in Illustration 
    *a
    Component without harness connected
    (Transmission Wire)



NG
Go to step 3
OK


2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)


    C223988E06
  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    E5-11 (SLU+) - E5-10 (SLU-)
    20°C (68°F)
    5.1 to 5.5 Ω
    E5-11 (SLU+) - Body ground
    Always
    10 kΩ or higher
    E5-10 (SLU-) - Body ground
    Always
    10 kΩ or higher

    Text in Illustration 
    *a
    Rear view of wire harness connector
    (to ECM)



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (Click here)  

3.INSPECT SHIFT SOLENOID VALVE SLU


    C224014E01
  1. Remove shift solenoid valve SLU.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    5.1 to 5.5 Ω

  1. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

    OK:
    Measurement Condition
    Specified Condition
    1. Battery positive (+) with a 21 W bulb → Terminal 2
    2. Battery negative (-) → Terminal 1
    Valve moves and makes an operating noise

Text in Illustration 
*a
Component without harness connected
(Shift Solenoid Valve SLU)


NG
REPLACE SHIFT SOLENOID VALVE SLU (Click here)
OK

REPAIR OR REPLACE TRANSMISSION WIRE (Click here)