DTC P043E Evaporative Emission System Leak Detection Reference Orifice Low Flow |
DTC P043F Evaporative Emission System Reference Orifice High Flow |
DTC P2401 Evaporative Emission Leak Detection Pump Stuck OFF |
DTC P2402 Evaporative Emission Leak Detection Pump Stuck ON |
DTC P2419 Evaporative Emission System Switching Valve Control Circuit Low |
| DTC No. | Monitoring Item | Malfunction Detection Condition | Trouble Area | Detection Timing | Detection Logic |
| P043E | Reference orifice clogged | P043E, P043F, P2401, P2402 and P2419 stored when one of following conditions met during key-off EVAP monitor:
|
| While ignition switch off | 2 trip |
| P043F | Reference orifice high-flow | ||||
| P2401 | Leak detection pump stuck OFF | ||||
| P2402 | Leak detection pump stuck ON | ||||
| P2419 | Vent valve stuck closed |
| Sequence | Operation | Description | Duration |
| - | ECM activation | Activated by soak timer, 5, 7 or 9.5 hours after ignition switch turned off. | - |
| A | Atmospheric pressure measurement | Vent valve is turned off (vent) and EVAP system pressure is measured by ECM in order to register atmospheric pressure. If pressure in EVAP system is not between 70 kPa(abs) and 110 kPa(abs) [525 mmHg(abs) and 825 mmHg(abs)], ECM cancels EVAP system monitor. | 60 seconds |
| B | First reference pressure measurement | In order to determine reference pressure, leak detection pump creates negative pressure (vacuum) through reference orifice and then ECM checks if leak detection pump and vent valve operate normally. | 60 seconds |
| C | EVAP system pressure measurement | Vent valve is turned on (closed) to shut EVAP system. Negative pressure (vacuum) is created in EVAP system, and EVAP system pressure is then measured. Write down measured value as it will be used in leak check If EVAP pressure does not stabilize within 15 minutes, ECM cancels EVAP system monitor. | 15 minutes* |
| D | Purge VSV monitor | Purge VSV is opened and then EVAP system pressure is measured by ECM. Large increase indicates normal. | 10 seconds |
| E | Second reference pressure measurement | After second reference pressure measurement, leak check is performed by comparing first and second reference pressure. If stabilized system pressure is higher than second reference pressure, ECM determines that EVAP system is leaking. | 60 seconds |
| - | Final check | Atmospheric pressure is measured and then monitoring result is recorded by ECM. | - |

| *1 | Purge VSV: OFF (closed) | *2 | Purge VSV: ON (open) |
| *3 | Vent Valve: OFF (vent) | *4 | Vent Valve: ON (closed) |
| *5 | Leak Detection Pump: OFF | *6 | Leak Detection Pump: ON |
| *7 | Reference Orifice (0.02 inch) | *8 | Canister Pressure Sensor |
| *9 | Canister | *10 | Fuel Tank |
| *11 | Canister Pump Module | *12 | Canister Filter |
| *a | Operation A: Atmospheric Pressure Measurement | *b | Operation B, E: Reference Pressure Measurement |
| *c | Operation C: EVAP System Pressure Measurement | *d | Operation D: Purge VSV Monitor |
| *e | Atmospheric Pressure | *f | Negative Pressure |

| Required Sensors/Components | Canister pump module |
| Frequency of Operation | Once per driving cycle |
| Duration | Within 2 minutes |
| MIL Operation | 2 driving cycles |
| Sequence of Operation | None |
| Monitor runs whenever following DTCs not present | None |
| Atmospheric pressure | 70 to 110 kPa(abs) [525 to 825 mmHg(abs)] |
| Battery voltage | 10.5 V or higher |
| Vehicle speed | Less than 4 km/h (2.5 mph) |
| Ignition switch | OFF |
| Time after key-off | 5, 7 or 9.5 hours |
| Canister pressure sensor malfunction (P0452, P0453) | Not detected |
| Purge VSV | Not operated by scan tool |
| Vent valve | Not operated by scan tool |
| Leak detection pump | Not operated by scan tool |
| Both of following conditions met before key-off | Conditions 1 and 2 |
| 1. Duration that vehicle has been driven | 5 minutes or more |
| 2. EVAP purge operation | Performed |
| Engine coolant temperature | 4.4 to 35°C (40 to 95°F) |
| Intake air temperature | 4.4 to 35°C (40 to 95°F) |
| One of following conditions met | - |
| EVAP pressure just after reference pressure measurement started | Higher than -1 kPa(gauge) [-7.5 mmHg(gauge)] |
| Reference pressure | Below -4.85 kPa(gauge) [-36.384 mmHg(gauge)] |
| Reference pressure | -1.157 kPa(gauge) [-8.68 mmHg(gauge)] or higher |
| Reference pressure | Not saturated within 55 seconds |
| Difference between first reference pressure and second reference pressure | 0.9 kPa(gauge) [6.76 mmHg(gauge)] or higher |
| Techstream Display | Description |
| NORMAL |
|
| ABNORMAL |
|
| INCOMPLETE |
|
| N/A |
|