Home › ENGINE · 2TR-FE › ENGINE CONTROL SYSTEM › SFI SYSTEM

DTC    P0412    Secondary Air Injection System Switching Valve "A" Circuit

for Preparation Click here


DESCRIPTION

The secondary air injection system consists of an air pump assembly, the air switching valve assembly, an air pressure sensor, the air injection control driver and the ECM. For a short time after cold engine starts, the secondary air injection system pumps secondary air to the exhaust port of the cylinder head to purify the exhaust emissions. The secondary air is supplied by the air pump assembly and is pumped to the exhaust port through the air switching valve assembly.
The air injection control driver drives the air switching valve assembly and the air pump assembly according to command signals transmitted by the ECM. The air pressure sensor detects the pressure in the secondary air passage when the secondary air injection system is ON and OFF, and transmits pressure signal to the ECM.
The air injection control driver is not only equipped to drive the pump and valve, but also with a diagnosis function to detect malfunctions in the secondary air injection system circuit.

HINT:
As a large current is required to drive the air pump assembly and air switching valve assembly, an air injection control driver is included in this system.


A121746E09


DTC No.
DTC Detection Condition
Trouble Area
P0412
  1. After cold engine starts, all of following conditions met (1 trip detection logic):
    1. Secondary air injection system not operating (air pump and air switching valve are off)
    2. Diagnostic signal from air injection control driver 31% or more, and 48% or less
    3. Battery voltage 8 V or higher
  1. Open in air switching valve drive circuit
  2. Short between air switching valve drive circuit and +B circuit
  3. Air injection control driver
  4. Air switching valve assembly
  5. ECM
  1. After cold engine starts, all of following conditions met (1 trip detection logic):
    1. Secondary air injection system operating (air pump and air switching valve are on)
    2. Diagnostic signal from air injection control driver 31% or more, and 48% or less
    3. Battery voltage 8 V or higher
  1. Short between air switching valve drive circuit and body ground
  2. Air injection control driver
  3. Air switching valve assembly
  4. ECM

MONITOR DESCRIPTION

The air injection control driver detects open and short circuits according to the voltages of the air pump assembly terminal and the air switching valve assembly terminal, and transmits diagnostic information as a signal to the ECM.
For a short time after cold engine starts, the ECM transmits command signals to the air injection control driver to drive the air pump assembly and air switching valve assembly.
The air injection control driver transmits an air switching valve malfunction signal to the ECM if either of the following conditions is met:
  1. The voltage at the air injection control driver terminal relating to the air switching valve assembly is low despite the air injection control driver receiving command signals from the ECM to drive the air switching valve assembly.
  2. The voltage at the air injection control driver terminal relating to the air switching valve is high despite the air injection control driver receiving no command signals from the ECM to drive the air switching valve assembly.
The ECM stores the DTC based on diagnostic signals from the air injection control driver.

MONITOR STRATEGY


Related DTCs
P0412: Secondary Air Injection System Air Switching Valve Circuit Range Check
Required Sensors/Components (Main)
Air injection control driver
Required Sensors/Components (Related)
Air switching valve assembly
Frequency of Operation
Once per drive cycle
Duration
3 seconds
MIL Operation
Immediate
Sequence of Operation
None

TYPICAL ENABLING CONDITIONS


Case 1: 
Monitor runs whenever following DTCs not present
-
All of following conditions are met
-
Secondary air injection pump
Operating
Secondary air switching valve
Operating
Battery voltage
8 V or more
Ignition switch
ON
Time after ignition switch OFF to ON
More than 0.5 seconds
Starter
OFF
Time after starter ON to OFF
More than 0.5 seconds

Case 2: 
Monitor runs whenever following DTCs not present
-
All of following conditions are met
-
Secondary air injection pump
Not operating
Secondary air switching valve
Not operating
Battery voltage
8 V or more
Ignition switch
ON
Time after ignition switch OFF to ON
More than 0.5 seconds
Starter
OFF
Time after starter ON to OFF
More than 0.5 seconds

TYPICAL MALFUNCTION THRESHOLDS


Diagnostic signal duty ratio from air injection control driver
31% or more, and 48% or less

COMPONENT OPERATING RANGE


Diagnostic signal duty ratio from air injection control driver
70% or more, and 90% or less when secondary air injection system operating.
0% when secondary air injection system not operating.

CONFIRMATION DRIVING PATTERN

NOTICE:
  1. This Secondary Air Injection Check only allows technicians to operate the secondary air injection system for a maximum of 5 seconds.
    Furthermore, the check can only be performed up to 4 times per trip. If the test is repeated, intervals of at least 30 seconds are required between checks.
    While secondary air injection system operation using the Techstream is prohibited, the Techstream display indicates the prohibition (WAIT or ERROR).
    If ERROR is displayed on the Techstream during the test, stop the engine for 10 minutes, and then try again.
  2. Performing the Secondary Air Injection Check repeatedly may cause damage to the secondary air injection system. If necessary, leave an interval of several minutes between System Check operations to prevent the system from overheating.
  3. When performing the Secondary Air Injection Check operation after the battery cable has been reconnected, wait for 7 minutes with the ignition switch turned to ON or the engine running.
  4. Turn the ignition switch off when the Secondary Air Injection Check operation finishes.

  1. Start the engine and warm it up.
  2. Turn the ignition switch off.
  3. Connect the Techstream to the DLC3.
  4. Turn the ignition switch to ON.
  5. Turn the Techstream on.
  6. Clear DTCs (even if no DTCs are stored, perform the clear DTC operation) (Click here).
  7. Turn the ignition switch off and wait for at least 30 seconds.
  8. Turn the ignition switch to ON and turn the Techstream on.
  9. Enter the following menus: Powertrain / Engine and ECT / Utility / Secondary Air Injection Check / Automatic Mode.
  10. Start the engine after the Techstream initialization is finished.
  11. Perform the System Check operation by pressing Next.
  12. Perform the following to confirm the secondary air injection system pending DTCs: Press the Exit.
  13. Check for pending DTCs.

    OK:
    No pending DTC is output.

  14. After the "Secondary Air injection check" is completed, check for All Readiness by entering the following menus: Powertrain / Engine and ECT / Utility / All Readiness.
  15. Input the DTC: P0412.
  16. Check the DTC judgment result.

    Techstream Display
    Description
    NORMAL
    1. DTC judgment completed
    2. System normal
    ABNORMAL
    1. DTC judgment completed
    2. System abnormal
    INCOMPLETE
    1. DTC judgment not completed
    2. Perform driving pattern after confirming DTC enabling conditions
    N/A
    1. Unable to perform DTC judgment
    2. Number of DTCs which do not fulfill DTC preconditions has reached ECU memory limit

    HINT:
    1. If the judgment result shows NORMAL, the system is normal.
    2. If the judgment result shows ABNORMAL, the system has a malfunction.

  17. If the test result is INCOMPLETE or N/A and no pending DTC is output, perform a universal trip and check for permanent DTCs (Click here).

    HINT:
    1. If a permanent DTC is output, the system is malfunctioning.
    2. If no permanent DTC is output, the system is normal.

  18. Turn the ignition switch off.

WIRING DIAGRAM


A237374E04


INSPECTION PROCEDURE

HINT:
  1. By using the Techstream to perform the Secondary Air Injection Check operation in the System Check, the air fuel ratio and the pressure in the secondary air injection system passage can be checked while the secondary air injection system is operating. This helps technicians to troubleshoot the system when it malfunctions
  2. Read freeze frame data using the Techstream. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air fuel ratio was lean or rich, and other data from the time the malfunction occurred.

1.INSPECT AIR SWITCHING VALVE ASSEMBLY
  1. Inspect the air switching valve assembly (Click here).



NG
REPLACE AIR SWITCHING VALVE ASSEMBLY (Click here)
OK


2.CHECK HARNESS AND CONNECTOR (AIR SWITCHING VALVE ASSEMBLY - BODY GROUND)
  1. Disconnect the air switching valve assembly connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    A10-1 - Body ground
    Always
    Below 1 Ω
    A10-2 - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


3.CHECK HARNESS AND CONNECTOR (AIR SWITCHING VALVE ASSEMBLY - AIR INJECTION CONTROL DRIVER)
  1. Disconnect the air switching valve assembly connector.

  1. Disconnect the air injection control driver connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    A10-2 - A7-6 (VV)
    Always
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE AIR INJECTION CONTROL DRIVER