Home › ENGINE · 2TR-FE › ENGINE CONTROL SYSTEM › SFI SYSTEM

DTC    P1613    Secondary Air Injection Driver Malfunction

for Preparation Click here


DESCRIPTION

Refer to DTC P0412 .

DTC No.
DTC Detection Condition
Trouble Area
P1613
Either of following conditions (1) or (2) met
(1) All of following conditions met (1 trip detection logic):
  1. Either of air pump assembly or air switching valve assembly not operating
  2. Diagnostic signal from air injection control driver 80%
  3. Battery voltage 8 V or more
(2) Both of following conditions met (1 trip detection logic):
  1. Battery voltage 8 V or more
  2. Diagnostic signal from air injection control driver abnormal (duty signal other than 0, 20, 40, 80 and 100%)
  1. Air injection control driver
  2. Open in air injection control driver ground circuit
  1. All of following conditions met (1 trip detection logic):
    1. Secondary air injection system operating (air switching valve and air pump are on)
    2. Diagnostic signal from air injection control driver 0%
    3. Battery voltage 8 V or more
  1. Short in diagnostic information signal circuit (air injection control driver - ECM)
  2. Open or short in air pump and air switching valve command signal circuit (air injection control driver - ECM)
  3. Open in air injection control driver ground circuit
  4. Air injection control driver
  5. ECM
  1. Both of following conditions met (1 trip detection logic):
    1. Battery voltage 8 V or more
    2. Diagnostic signal from air injection control driver 100%
  1. Open or short in air injection control driver power source circuit
  2. Open in diagnostic information signal circuit (air injection control driver - ECM)
  3. Air injection control driver
  4. ECM

MONITOR DESCRIPTION

For a short time after cold engine starts, the ECM transmits command signals to the air injection control driver to drive the air pump assembly and the air switching valve assembly. The air injection control driver detects open and short circuits according to the voltages at the air injection control driver terminals to the air pump assembly and air switching valve assembly, and the circuit voltage of the air injection control driver power source, and transmits diagnostic information as a signal to the ECM.
If the secondary air injection system circuit or the air injection control driver itself malfunctions, the air injection control driver sends a malfunction signal (duty signal) as diagnostic information to the ECM (when the system is normal, a system normal signal is sent). The ECM stores the DTC based on the diagnostic information from the air injection control driver.
EXAMPLE:
  1. The duty ratio of the diagnostic signal from the air injection control driver is 0 or 100% (remains at 0 V or the same as battery voltage).
  2. The duty ratio of the diagnostic signal from the air injection control driver shows an impossible ratio (other than 0, 20, 40, 80 and 100%).
  3. The air injection control driver outputs the normal signal (normal duty signal: 80%) while the system is not operating.

MONITOR STRATEGY


Related DTCs
P1613: Secondary Air Injection System Air Injection Control Driver Circuit Range Check
Required Sensors/Components (Main)
Air injection control driver
Required Sensors/Components (Related)
Air switching valve
Frequency of Operation
Once per drive cycle
Duration
3 seconds
MIL Operation
Immediate
Sequence of Operation
None

TYPICAL ENABLING CONDITIONS


Case 1 and 4: 
Monitor runs whenever following DTCs not present
None
Battery voltage
8 V or more
Ignition switch
ON
Starter
OFF

Case 2: 
Monitor runs whenever following DTCs not present
None
Either a or b met:
-
a. Air pump
Not operating
b. Air switching valve
Not operating
Battery voltage
8 V or more
Ignition switch
ON
Starter
OFF

Case 3: 
Monitor runs whenever following DTCs not present
None
Following conditions (a) and (b) met
-
a. Air pump
Operating
b. Air switching valve
Operating
Battery voltage
8 V or more
Ignition switch
ON
Starter
OFF

TYPICAL MALFUNCTION THRESHOLDS


Case 1: 
One of following conditions met:
A, B, C or D
A. Diagnostic signal duty ratio from air injection control driver
1% or more, and 10% or less
B. Diagnostic signal duty ratio from air injection control driver
30%
C. Diagnostic signal duty ratio from air injection control driver
49%
D. Diagnostic signal duty ratio from air injection control driver
91% or more, and 99% or less

Case 2: 
Diagnostic signal duty ratio from air injection control driver
70% or more, and 90% or less

Case 3: 
Diagnostic signal duty ratio from air injection control driver
0%

Case 4: 
Diagnostic signal duty ratio from air injection control driver
100%

COMPONENT OPERATING RANGE


Diagnostic signal duty ratio from air injection control driver
70% or more, and 90% or less when secondary air injection system operating.
0% when secondary air injection system not operating.

CONFIRMATION DRIVING PATTERN

NOTICE:
  1. This Secondary Air Injection Check only allows technicians to operate the secondary air injection system for a maximum of 5 seconds.
    Furthermore, the check can only be performed up to 4 times per trip. If the test is repeated, intervals of at least 30 seconds are required between checks.
    While secondary air injection system operation using the Techstream is prohibited, the Techstream display indicates the prohibition (WAIT or ERROR).
    If ERROR is displayed on the Techstream during the test, stop the engine for 10 minutes, and then try again.
  2. Performing the Secondary Air Injection Check repeatedly may cause damage to the secondary air injection system. If necessary, leave an interval of several minutes between System Check operations to prevent the system from overheating.
  3. When performing the Secondary Air Injection Check operation after the battery cable has been reconnected, wait for 7 minutes with the ignition switch turned to ON or the engine running.
  4. Turn the ignition switch off when the Secondary Air Injection Check operation finishes.

  1. Start the engine and warm it up.
  2. Turn the ignition switch off.
  3. Connect the Techstream to the DLC3.
  4. Turn the ignition switch to ON.
  5. Turn the Techstream on.
  6. Clear DTCs (even if no DTCs are stored, perform the clear DTC operation) (Click here).
  7. Turn the ignition switch off and wait for at least 30 seconds.
  8. Turn the ignition switch to ON and turn the Techstream on.
  9. Enter the following menus: Powertrain / Engine and ECT / Utility / Secondary Air Injection Check / Automatic Mode.
  10. Start the engine after the Techstream initialization is finished.
  11. Perform the System Check operation by pressing Next.
  12. Perform the following to confirm the secondary air injection system pending DTCs: Press the Exit.
  13. Check for pending DTCs.

    OK:
    No pending DTC is output.

  14. After the "Secondary Air injection check" is completed, check for All Readiness by entering the following menus: Powertrain / Engine and ECT / Utility / All Readiness.
  15. Input the DTC: P1613.
  16. Check the DTC judgment result.

    Techstream Display
    Description
    NORMAL
    1. DTC judgment completed
    2. System normal
    ABNORMAL
    1. DTC judgment completed
    2. System abnormal
    INCOMPLETE
    1. DTC judgment not completed
    2. Perform driving pattern after confirming DTC enabling conditions
    N/A
    1. Unable to perform DTC judgment
    2. Number of DTCs which do not fulfill DTC preconditions has reached ECU memory limit

    HINT:
    1. If the judgment result shows NORMAL, the system is normal.
    2. If the judgment result shows ABNORMAL, the system has a malfunction.

  17. If the test result is INCOMPLETE or N/A and no pending DTC is output, perform a universal trip and check for permanent DTCs (Click here).

    HINT:
    1. If a permanent DTC is output, the system is malfunctioning.
    2. If no permanent DTC is output, the system is normal.

  18. Turn the ignition switch off.

WIRING DIAGRAM

Refer to DTC P0412 .

INSPECTION PROCEDURE

CAUTION:
Inspect the fuses for circuits related to this system before performing the following inspection procedure.

HINT:
  1. By using the Techstream to perform the Secondary Air Injection Check operation in the System Check, the air fuel ratio and the pressure in the secondary air injection system passage can be checked while the secondary air injection system is operating. This helps technicians to troubleshoot the system when it malfunctions.
  2. Read freeze frame data using the Techstream. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air fuel ratio was lean or rich, and other data from the time the malfunction occurred.

1.CHECK ANY OTHER DTCS OUTPUT (IN ADDITION TO DTC P1613)
  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the Techstream on.

  1. Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.

  1. Read DTCs.
    Result 
    Result
    Proceed to
    DTC P1613 is output
    A
    DTC P1613 and other DTCs are output
    B
    If any DTCs other than P1613 are output, troubleshoot those DTCs first.



B
GO TO DTC CHART (Click here)
A


2.PERFORM ACTIVE TEST USING TECHSTREAM (AIDI VOLTAGE)
A065741E75
  1. Start the engine and warm it up.

  1. Turn the ignition switch off.

  1. Connect the Techstream to the DLC3.
    Text in Illustration 
    *a
    Component with harness connected
    (ECM)

  1. Turn the ignition switch to ON.

  1. Turn the Techstream on.

  1. Enter the following menus: Powertrain / Engine and ECT / Utility / Secondary Air Injection Check / Manual Mode / AIR PUMP: ON, ASV: CLOSE.

    HINT:
    When Manual Mode is selected, the Techstream initialization (atmospheric pressure measurement) is performed automatically. The initialization takes 10 seconds. After the initialization, AIR PUMP and ASV operation can be selected.

  1. Start the engine.

  1. Perform the secondary air injection system intrusive operation while the engine is idling.

  1. Measure the voltage between the AIDI and E1 terminals of the ECM connector when the secondary air injection system is on and off.

  1. Turn the ignition switch off.

    NOTICE:
    1. Do not perform the System Check operation repetitively. It may cause the damage in the system. If necessary, leave an interval of several minutes between System Check operations.
    2. When performing the Secondary Air Injection Check operation after the battery cable has been reconnected, wait for 7 minutes with the ignition switch turned to ON or the engine running.
    3. Turn the ignition switch off when the Secondary Air Injection Check operation finishes.


    Result 
    Result
    Suspected Trouble Area
    Proceed to
    Fixed at low (1.6 V or less) even when secondary air injection system ON (AIR PUMP ON, ASV OPEN)
    1. Short between air pump or air switching valve command signal circuit and body ground
    2. Open in air pump command signal circuit (between ECM and air injection control driver)
    3. Open in air switching valve command signal circuit (between ECM and air injection control driver)
    4. Open in air injection control driver ground circuit (between air injection control driver and body ground)
    5. Diagnostic signal circuit ground short
    6. Air injection control driver
    7. ECM
    A
    Fixed at high (12 V or more) even when secondary air injection system OFF (AIR PUMP OFF, ASV CLOSE)
    1. Open in diagnostic signal circuit (ECM - air injection control driver)
    2. Short between +B and diagnostic signal circuits (ECM - air injection control driver)
    3. Open in air injection control driver power source circuit
    4. Air injection control driver
    5. ECM
    B
    Other than above:
    Fluctuating (duty signal other than 20, 40 and 80%)
    1. Air injection control driver
    2. Open in air injection control driver ground circuit (between air injection control driver and body ground)
    C



B
Go to step 5

C
Go to step 8
A


3.INSPECT ECM (AIRP AND AIRV VOLTAGE)
A065741E76
  1. Turn the ignition switch to ON.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    E4-11 (AIRP) - E4-3 (E1)
    Ignition Switch ON
    11 to 14 V
    E4-24 (AIRV) - E4-3 (E1)
    Ignition Switch ON
    11 to 14 V

    Text in Illustration 
    *a
    Component with harness connected
    (ECM)



NG
Go to step 4
OK

REPLACE ECM (Click here)  

4.CHECK HARNESS AND CONNECTOR (ECM - AIR INJECTION CONTROL DRIVER)
  1. Disconnect the ECM connector.

  1. Disconnect the air injection control driver connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Condition
    Specified Condition
    A7-1 (E) - Body ground
    Always
    Below 1 Ω
    A7-4 (SIP) - E4-11 (AIRP)
    Always
    Below 1 Ω
    A7-3 (SIV) - E4-24 (AIRV)
    Always
    Below 1 Ω



    B053781E37
  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    A7-2 (DI) - A7-1 (E)
    Ignition Switch ON
    11 to 14 V

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Air Injection Control Driver)
    Result 
    Result
    Proceed to
    NG
    A
    OK
    B



B
Go to step 9
A

REPAIR OR REPLACE HARNESS OR CONNECTOR 

5.CHECK TERMINAL VOLTAGE (POWER SOURCE OF AIR INJECTION CONTROL DRIVER)
B053781E43
  1. Disconnect the air injection control driver connector.

  1. Turn the ignition switch to ON.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    A7-5 (+B) - Body ground
    Ignition Switch ON
    11 to 14 V

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Air Injection Control Driver)

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    E4-11 (AIRP) or A7-4 (SIP) - Body ground
    Always
    10 kΩ or higher
    E4-24 (AIRV) or A7-3 (SIV) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


6.INSPECT AIR INJECTION CONTROL DRIVER (DI TERMINAL VOLTAGE)
B053781E37
  1. Disconnect the air injection control driver connector.

  1. Turn the ignition switch to ON.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    A7-2 (DI) - A7-1 (E)
    Ignition Switch ON
    11 to 14 V

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Air Injection Control Driver)



OK
Go to step 9

NG
Go to step 7

7.CHECK HARNESS AND CONNECTOR (ECM - AIR INJECTION CONTROL DRIVER)
  1. Disconnect the ECM connector.

  1. Disconnect the air injection control driver connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Condition
    Specified Condition
    A7-2 (DI) - E5-20 (AIDI)
    Always
    Below 1 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Condition
    Specified Condition
    A7-2 (DI) or E5-20 (AIDI) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (Click here)  

8.CHECK HARNESS AND CONNECTOR (AIR INJECTION CONTROL DRIVER - BODY GROUND)
  1. Disconnect the air injection control driver connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Condition
    Specified Condition
    A7-1 (E) - Body ground
    Always
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


9.PERFORM ACTIVE TEST USING TECHSTREAM
  1. Disconnect the air injection control driver connector.



    A229922E27
  1. Connect terminals DI and SIV of the wire harness connector for the air injection control driver.

Text in Illustration 
*1
Air Injection Control Driver
*2
ECM
*a
Front view of wire harness connector
(to Air Injection Control Driver)
  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the Techstream on.

  1. Enter the following menus: Powertrain / Engine and ECT / Utility / Secondary Air Injection Check / Manual Mode / AIR PUMP: ON, ASV: OPEN.

    HINT:
    When Manual Mode is selected, the Techstream initialization (atmospheric pressure measurement) is performed automatically. The initialization takes 10 seconds. After the initialization, AIR PUMP and ASV operation can be selected.

  1. Start the engine.

  1. Perform the secondary air injection system forced operation while the engine is idling.

  1. Measure the voltage between the SIV and E terminals of the ECM connector when the secondary air injection system is on and off.

  1. Turn the ignition switch off.

    NOTICE:
    1. Do not perform the System Check operation repetitively. It may cause the damage in the system. If necessary, leave an interval of several minutes between System Check operations.
    2. When performing the Secondary Air Injection Check operation after the battery cable has been reconnected, wait for 7 minutes with the ignition switch ON or the engine running.
    3. Turn the ignition switch off when the Secondary Air Injection Check operation finishes.


    Standard Voltage:

    Tester Connection
    Condition
    Specified Condition
    A7-3 (SIV) - A7-1 (E)
    AIR PUMP: ON, ASV: OPEN
    0.5 to 2 V
    A7-3 (SIV) - A7-1 (E)
    AIR PUMP: OFF, ASV: CLOSE
    11 to 14 V



    A229922E28
  1. Connect terminals DI and SIP of the wire harness connector for the air injection control driver.

Text in Illustration 
*1
Air Injection Control Driver
*2
ECM
*a
Front view of wire harness connector
(to Air Injection Control Driver)
  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the Techstream on.

  1. Enter the following menus: Powertrain / Engine and ECT / Utility / Secondary Air Injection Check / Manual Mode / AIR PUMP: ON, ASV: OPEN.

    HINT:
    When Manual Mode is selected, the Techstream initialization (atmospheric pressure measurement) is performed automatically. The initialization takes 10 seconds. After the initialization, AIR PUMP and ASV operation can be selected.

  1. Start the engine.

  1. Perform the secondary air injection system forced operation while the engine is idling.

  1. Measure the voltage between the SIP and E terminals of the ECM connector when the secondary air injection system is on and off.

  1. Turn the ignition switch off.

    NOTICE:
    1. Do not perform the System Check operation repetitively. It may cause the damage in the system. If necessary, leave an interval of several minutes between System Check operations.
    2. When performing the Secondary Air Injection Check operation after the battery cable has been reconnected, wait for 7 minutes with the ignition switch ON or the engine running.
    3. Turn the ignition switch off when the Secondary Air Injection Check operation finishes.


    Standard Voltage:

    Tester Connection
    Condition
    Specified Condition
    A7-4 (SIP) - A7-1 (E)
    AIR PUMP: ON, ASV: OPEN
    0.5 to 2 V
    A7-4 (SIP) - A7-1 (E)
    AIR PUMP: OFF, ASV: CLOSE
    11 to 14 V



NG
REPLACE ECM (Click here)
OK


10.REPLACE AIR INJECTION CONTROL DRIVER
  1. Replace the air injection control driver.


NEXT


11.CHECK WHETHER DTC OUTPUT RECURS (SYSTEM CHECK AUTOMATIC MODE)
  1. Start the engine and warm it up.

  1. Turn the ignition switch off.

  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the Techstream on.

  1. Clear DTCs (even if no DTCs are stored, perform the clear DTC operation) (Click here).

  1. Enter the following menus: Powertrain / Engine and ECT / Utility / Secondary Air Injection Check / Automatic Mode.

  1. Start the engine after the Techstream initialization is finished.

  1. Perform the System Check operation by pressing Next.

  1. After operating the secondary air injection system, perform the following to confirm the secondary air injection system pending DTCs: Press the Exit.

  1. Check Pending DTCs.

    OK:
    No pending DTC output.

  1. Turn the ignition switch off.

    NOTICE:
    1. When performing the Secondary Air Injection Check operation after the battery cable has been reconnected, wait for 7 minutes with the ignition switch turned to ON or the engine running.
    2. Turn the ignition switch off when the Secondary Air Injection Check operation finishes.



NG
REPLACE ECM (Click here)
OK