DTC P1613 Secondary Air Injection Driver Malfunction |
| DTC No. | DTC Detection Condition | Trouble Area |
| P1613 | Either of following conditions (1) or (2) met (1) All of following conditions met (1 trip detection logic):
|
|
|
| |
|
|
| Related DTCs | P1613: Secondary Air Injection System Air Injection Control Driver Circuit Range Check |
| Required Sensors/Components (Main) | Air injection control driver |
| Required Sensors/Components (Related) | Air switching valve |
| Frequency of Operation | Once per drive cycle |
| Duration | 3 seconds |
| MIL Operation | Immediate |
| Sequence of Operation | None |
| Monitor runs whenever following DTCs not present | None |
| Battery voltage | 8 V or more |
| Ignition switch | ON |
| Starter | OFF |
| Monitor runs whenever following DTCs not present | None |
| Either a or b met: | - |
| a. Air pump | Not operating |
| b. Air switching valve | Not operating |
| Battery voltage | 8 V or more |
| Ignition switch | ON |
| Starter | OFF |
| Monitor runs whenever following DTCs not present | None |
| Following conditions (a) and (b) met | - |
| a. Air pump | Operating |
| b. Air switching valve | Operating |
| Battery voltage | 8 V or more |
| Ignition switch | ON |
| Starter | OFF |
| One of following conditions met: | A, B, C or D |
| A. Diagnostic signal duty ratio from air injection control driver | 1% or more, and 10% or less |
| B. Diagnostic signal duty ratio from air injection control driver | 30% |
| C. Diagnostic signal duty ratio from air injection control driver | 49% |
| D. Diagnostic signal duty ratio from air injection control driver | 91% or more, and 99% or less |
| Diagnostic signal duty ratio from air injection control driver | 70% or more, and 90% or less |
| Diagnostic signal duty ratio from air injection control driver | 0% |
| Diagnostic signal duty ratio from air injection control driver | 100% |
| Diagnostic signal duty ratio from air injection control driver | 70% or more, and 90% or less when secondary air injection system operating. 0% when secondary air injection system not operating. |
| Techstream Display | Description |
| NORMAL |
|
| ABNORMAL |
|
| INCOMPLETE |
|
| N/A |
|
| 1.CHECK ANY OTHER DTCS OUTPUT (IN ADDITION TO DTC P1613) |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.
Read DTCs.
| Result | Proceed to |
| DTC P1613 is output | A |
| DTC P1613 and other DTCs are output | B |
|
| ||||
| A | |
| 2.PERFORM ACTIVE TEST USING TECHSTREAM (AIDI VOLTAGE) |
![]() |
Start the engine and warm it up.
Turn the ignition switch off.
Connect the Techstream to the DLC3.
| *a | Component with harness connected (ECM) |
Turn the ignition switch to ON.
Turn the Techstream on.
Enter the following menus: Powertrain / Engine and ECT / Utility / Secondary Air Injection Check / Manual Mode / AIR PUMP: ON, ASV: CLOSE.
Start the engine.
Perform the secondary air injection system intrusive operation while the engine is idling.
Measure the voltage between the AIDI and E1 terminals of the ECM connector when the secondary air injection system is on and off.
Turn the ignition switch off.
| Result | Suspected Trouble Area | Proceed to |
| Fixed at low (1.6 V or less) even when secondary air injection system ON (AIR PUMP ON, ASV OPEN) |
| A |
| Fixed at high (12 V or more) even when secondary air injection system OFF (AIR PUMP OFF, ASV CLOSE) |
| B |
| Other than above: Fluctuating (duty signal other than 20, 40 and 80%) |
| C |
|
| ||||
|
| ||||
| A | |
| 3.INSPECT ECM (AIRP AND AIRV VOLTAGE) |
![]() |
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| E4-11 (AIRP) - E4-3 (E1) | Ignition Switch ON | 11 to 14 V |
| E4-24 (AIRV) - E4-3 (E1) | Ignition Switch ON | 11 to 14 V |
| *a | Component with harness connected (ECM) |
|
| ||||
| OK | ||
| ||
| 4.CHECK HARNESS AND CONNECTOR (ECM - AIR INJECTION CONTROL DRIVER) |
Disconnect the ECM connector.
Disconnect the air injection control driver connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A7-1 (E) - Body ground | Always | Below 1 Ω |
| A7-4 (SIP) - E4-11 (AIRP) | Always | Below 1 Ω |
| A7-3 (SIV) - E4-24 (AIRV) | Always | Below 1 Ω |
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A7-2 (DI) - A7-1 (E) | Ignition Switch ON | 11 to 14 V |
| *a | Front view of wire harness connector (to Air Injection Control Driver) |
| Result | Proceed to |
| NG | A |
| OK | B |
|
| ||||
| A | ||
| ||
| 5.CHECK TERMINAL VOLTAGE (POWER SOURCE OF AIR INJECTION CONTROL DRIVER) |
![]() |
Disconnect the air injection control driver connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A7-5 (+B) - Body ground | Ignition Switch ON | 11 to 14 V |
| *a | Front view of wire harness connector (to Air Injection Control Driver) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| E4-11 (AIRP) or A7-4 (SIP) - Body ground | Always | 10 kΩ or higher |
| E4-24 (AIRV) or A7-3 (SIV) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | |
| 6.INSPECT AIR INJECTION CONTROL DRIVER (DI TERMINAL VOLTAGE) |
![]() |
Disconnect the air injection control driver connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A7-2 (DI) - A7-1 (E) | Ignition Switch ON | 11 to 14 V |
| *a | Front view of wire harness connector (to Air Injection Control Driver) |
|
| ||||
|
| ||||
| 7.CHECK HARNESS AND CONNECTOR (ECM - AIR INJECTION CONTROL DRIVER) |
Disconnect the ECM connector.
Disconnect the air injection control driver connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A7-2 (DI) - E5-20 (AIDI) | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
| A7-2 (DI) or E5-20 (AIDI) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||
| 8.CHECK HARNESS AND CONNECTOR (AIR INJECTION CONTROL DRIVER - BODY GROUND) |
Disconnect the air injection control driver connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A7-1 (E) - Body ground | Always | Below 1 Ω |
|
| ||||
| OK | |
| 9.PERFORM ACTIVE TEST USING TECHSTREAM |
Disconnect the air injection control driver connector.
![]() |
Connect terminals DI and SIV of the wire harness connector for the air injection control driver.
| *1 | Air Injection Control Driver |
| *2 | ECM |
| *a | Front view of wire harness connector (to Air Injection Control Driver) |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Enter the following menus: Powertrain / Engine and ECT / Utility / Secondary Air Injection Check / Manual Mode / AIR PUMP: ON, ASV: OPEN.
Start the engine.
Perform the secondary air injection system forced operation while the engine is idling.
Measure the voltage between the SIV and E terminals of the ECM connector when the secondary air injection system is on and off.
Turn the ignition switch off.
| Tester Connection | Condition | Specified Condition |
| A7-3 (SIV) - A7-1 (E) | AIR PUMP: ON, ASV: OPEN | 0.5 to 2 V |
| A7-3 (SIV) - A7-1 (E) | AIR PUMP: OFF, ASV: CLOSE | 11 to 14 V |
![]() |
Connect terminals DI and SIP of the wire harness connector for the air injection control driver.
| *1 | Air Injection Control Driver |
| *2 | ECM |
| *a | Front view of wire harness connector (to Air Injection Control Driver) |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Enter the following menus: Powertrain / Engine and ECT / Utility / Secondary Air Injection Check / Manual Mode / AIR PUMP: ON, ASV: OPEN.
Start the engine.
Perform the secondary air injection system forced operation while the engine is idling.
Measure the voltage between the SIP and E terminals of the ECM connector when the secondary air injection system is on and off.
Turn the ignition switch off.
| Tester Connection | Condition | Specified Condition |
| A7-4 (SIP) - A7-1 (E) | AIR PUMP: ON, ASV: OPEN | 0.5 to 2 V |
| A7-4 (SIP) - A7-1 (E) | AIR PUMP: OFF, ASV: CLOSE | 11 to 14 V |
|
| ||||
| OK | |
| 10.REPLACE AIR INJECTION CONTROL DRIVER |
Replace the air injection control driver.
| NEXT | |
| 11.CHECK WHETHER DTC OUTPUT RECURS (SYSTEM CHECK AUTOMATIC MODE) |
Start the engine and warm it up.
Turn the ignition switch off.
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Clear DTCs (even if no DTCs are stored, perform the clear DTC operation) (Click here).
Enter the following menus: Powertrain / Engine and ECT / Utility / Secondary Air Injection Check / Automatic Mode.
Start the engine after the Techstream initialization is finished.
Perform the System Check operation by pressing Next.
After operating the secondary air injection system, perform the following to confirm the secondary air injection system pending DTCs: Press the Exit.
Check Pending DTCs.
Turn the ignition switch off.
|
| ||||
| OK | ||
| ||