Home › BODY ELECTRICAL › METER › METER / GAUGE SYSTEM

METER / GAUGE SYSTEM > Meter Illumination is Always Dark

for Preparation Click here


DESCRIPTION

When the ignition switch is turned to ACC or ON, the accessory meter operates as follows.
w/ Cruise Information:
The accessory meter receives light control switch signals and combination meter signals, and performs illumination dim operations.
w/o Cruise Information:
The accessory meter receives light control switch signals and performs illumination dim operations.

WIRING DIAGRAM


E146710E02


INSPECTION PROCEDURE

1.CHECK ILLUMINATION FUNCTION
  1. Check the illumination function.
    Result 
    Result
    Proceed to
    Accessory meter illumination is always dark
    A
    Combination meter illumination is always dark
    B



B
Go to PROBLEM SYMPTOMS TABLE (Click here)
A


2.INSPECT FUSE (PANEL)
  1. Remove the PANEL fuse from the main body ECU.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    PANEL fuse
    Always
    Below 1 Ω



NG
REPLACE FUSE
OK


3.CHECK HARNESS AND CONNECTOR (ACCESSORY METER - BATTERY)


    E146701E02
  1. Disconnect the K20 accessory meter connector.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    K20-21 (ILL+) - Body ground
    Light control switch ON
    11 to 14 V

    Result 
    Result
    Proceed to
    OK (w/ Cruise Information)
    A
    OK (w/o Cruise Information)
    B
    NG
    C



B
Go to step 7

C
REPAIR OR REPLACE HARNESS OR CONNECTOR
A


4.CHECK HARNESS AND CONNECTOR (COMBINATION METER - ACCESSORY METER AND BODY GROUND)


    E146704E03
  1. Disconnect the J28 combination meter connector.

  1. Disconnect the K20 accessory meter connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    J28-37 (ILL-) - K20-20 (ILL-)
    Always
    Below 1 Ω
    J28-40 (E1) - Body ground
    J28-37 (ILL-) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


5.REPLACE ACCESSORY METER ASSEMBLY
  1. Temporarily replace the accessory meter with a new or normally functioning one (Click here).


NEXT


6.CHECK ACCESSORY METER ASSEMBLY (OPERATION)
  1. Check the accessory meter operation.

    OK:
    Operation of the accessory meter returns to normal.



NG
REPLACE COMBINATION METER ASSEMBLY (Click here)
OK

END (ACCESSORY METER IS DEFECTIVE) 

7.CHECK HARNESS AND CONNECTOR (ACCESSORY METER - BODY GROUND)


    E146701E04
  1. Disconnect the K20 accessory meter connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    K20-12 (E) - Body ground
    Always
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


8.REPLACE ACCESSORY METER ASSEMBLY
  1. Temporarily replace the accessory meter with a new or normally functioning one (Click here).


NEXT


9.CHECK ACCESSORY METER ASSEMBLY (OPERATION)
  1. Check that the accessory meter operation is normal.

    OK:
    Operation of the accessory meter returns to normal.



NG
REPLACE COMBINATION METER ASSEMBLY (Click here)
OK

END (ACCESSORY METER IS DEFECTIVE)