Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › CONDENSER

CONDENSER > INSTALLATION

for Preparation Click here



1. INSTALL COOLER DRYER


    E050386E01
  1. Using pliers, install the cooler dryer.



    E055408E01
  1. Apply a sufficient amount of compressor oil to the contact surfaces of a new O-ring and the cap.

    Compressor oil:
    ND-OIL 8 or equivalent

  1. Install the O-ring to the cap.



    I030086E01
  1. Using a 14 mm socket hexagon wrench, install the cap to the modulator.

    Torque:
    2.9 N*m{ 30 kgf*cm , 26 in.*lbf }



2. INSTALL COOLER CONDENSER ASSEMBLY


    E190302E01
  1. Install the cooler condenser with the 2 bolts, as shown in the illustration.

    Torque:
    9.8 N*m{ 100 kgf*cm , 87 in.*lbf }



3. CONNECT AIR CONDITIONING TUBE AND ACCESSORY ASSEMBLY


E186078
  1. Remove the attached vinyl tape from the pipe and the connecting part of the cooler condenser.

  1. Sufficiently apply compressor oil to a new O-ring and the fitting surface of the pipe joint.

    Compressor oil:
    ND-OIL 8 or equivalent

  1. Install the O-ring on the air conditioning tube and accessory.

  1. Connect the air conditioning tube and accessory on the cooler condenser with the 2 bolts.

    Torque:
    9.8 N*m{ 100 kgf*cm , 87 in.*lbf }

    NOTICE:
    1. When tightening the bolt, do not allow any tools to contact the pipe.
    2. When tightening the bolt, hold a part of the pipe near the connector.



4. CONNECT DISCHARGE HOSE


E187984E04
  1. Remove the attached vinyl tape from the hose and the connecting part of the cooler condenser.

  1. Sufficiently apply compressor oil to a new O-ring and the fitting surface of the hose joint.

    Compressor oil:
    ND-OIL 8 or equivalent

  1. Install the O-ring on the discharge hose.

  1. Connect the discharge hose on the cooler condenser with the bolt.

    Torque:
    9.8 N*m{ 100 kgf*cm , 87 in.*lbf }

    NOTICE:
    1. When tightening the bolt, do not allow any tools to contact the pipe.
    2. When tightening the bolt, hold a part of the pipe near the connector.



5. INSTALL RADIATOR ASSEMBLY
  1. for 1GR-FE:
    Install the radiator (Click here).

  1. for 1UR-FE:
    Install the radiator .

  1. for 3UR-FE:
    Install the radiator (Click here).

  1. for 3UR-FBE:
    Install the radiator (Click here).



6. CONNECT OIL COOLER HOSE (w/ Air Cooled Transmission Oil Cooler)


    E188044
  1. Connect the 2 oil cooler hoses and attach the 2 clips.



7. INSTALL FRONT BUMPER COVER
  1. for Steel Type Bumper:
    Install the front bumper cover (Click here).

  1. for Resin Type Bumper:
    Install the front bumper cover (Click here).



8. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL


9. CHARGE REFRIGERANT
SST
09985-20010   (09985-02010, 09985-02050, 09985-02060, 09985-02070, 09985-02090, 09985-02110, 09985-02130, 09985-02150)
  1. Perform vacuum purging using a vacuum pump.



  1. Charge refrigerant HFC-134a (R134a).

    Standard:
    600 +/-30 g (21.2 +/-1.1 oz.)



    I037365E21

    NOTICE:
    1. Do not operate the cooler compressor before charging refrigerant as the cooler compressor will not work properly without any refrigerant, and will overheat.
    2. Approximately 200 g (7.05 oz.) of refrigerant may need to be charged after bubbles disappear. The refrigerant amount should be checked by measuring its quantity, and not with the sight glass.



10. WARM UP ENGINE
  1. Warm up the engine at less than 1500 rpm for 1 minute or more after charging the refrigerant.

    NOTICE:
    Be sure to warm up the compressor when turning the A/C switch ON after removing and installing the cooler refrigerant lines (including the compressor), to prevent damage to the compressor.



11. CHECK FOR REFRIGERANT GAS LEAK
  1. After recharging the refrigerant gas, check for refrigerant gas leakage using a halogen leak detector.

  1. Perform the operation under the following conditions:

    1. The ignition switch is OFF.
    2. The vehicle is in a place with good air ventilation and without any volatile gases, such as evaporated gasoline or exhaust gas. The detector is very sensitive to volatile gases.
    3. Some refrigerant is remaining in the refrigerant system.
    4. The compressor is off and its pressure is approximately 392 to 588 kPa (4.0 to 6.0 kgf/cm2, 57 to 85 psi).



    I042222E22
  1. Using a halogen leak detector, check the refrigerant line for leakage.

  1. If a gas leak is not detected on the drain hose, remove the blower motor control (blower resistor) from the cooling unit. Insert the halogen leak detector sensor into the unit and perform the test.

  1. Disconnect the connector and wait for approximately 20 minutes. Bring the halogen leak detector close to the pressure switch and perform the test.



12. CHECK SRS WARNING LIGHT
  1. Check the SRS warning light (Click here).