DTC B1500 Fuel Sender Open Detected |
| DTC Code | DTC Detection Condition | Trouble Area |
| B1500 | When combination meter detects fuel sender gauge malfunction |
|

| 1.READ VALUE USING TECHSTREAM (FUEL SENDER GAUGE) |
Operate the Techstream according to the display and select the "Data List" (Click here).
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Fuel Input | Fuel sender gauge (main) input signal/Min.: 0, Max.: 127.5 | Fuel sender input value | Unit: L |
|
| ||||
| OK | ||
| ||
| 2.CHECK HARNESS AND CONNECTOR (COMBINATION METER - FUEL SENDER GAUGE AND BODY GROUND) |
![]() |
Disconnect the J28 meter connector.
Disconnect the R6 gauge connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| J28-12 (L) - R6-2 | Always | Below 1 Ω |
| J28-39 (E3) - R6-3 | ||
| J28-40 (E1) - Body ground | ||
| J28-12 (L) or R6-2 - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | |
| 3.INSPECT FUEL SENDER GAUGE ASSEMBLY |
![]() |
Remove the fuel sender gauge.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 2 - 3 | Float level is F (upper) | 12 to 18 Ω |
| Float level is E (lower) | 405 to 415 Ω |
| Result | Proceed to |
| OK | A |
| NG (for 1GR-FE) | B |
| NG (for 1UR-FE) | C |
| NG (for 3UR-FE) | D |
| NG (for 3UR-FBE) | E |
|
| ||||
|
| ||||
|
| ||||
|
| ||||
| A | ||
| ||