Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System)

DTC    B1413/13    Evaporator Temperature Sensor Circuit

for Preparation Click here


DESCRIPTION

The No. 1 cooler thermistor (evaporator temperature sensor) is installed on the evaporator in the air conditioner unit to detect the cooled air temperature that has passed through the evaporator and control the air conditioning. It sends appropriate signals to the air conditioning amplifier. The resistance of the No. 1 cooler thermistor (evaporator temperature sensor) changes in accordance with the cooled air temperature that has passed through the evaporator. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier applies voltage (5 V) to the No. 1 cooler thermistor (evaporator temperature sensor) and reads voltage changes as the resistance of the No. 1 cooler thermistor (evaporator temperature sensor) changes. This sensor is used for frost prevention.

DTC Code
DTC Detection Condition
Trouble Area
B1413/13
Open or short in evaporator temperature sensor circuit
  1. No. 1 cooler thermistor (evaporator temperature sensor)
  2. Air conditioning harness
  3. Air conditioning amplifier

WIRING DIAGRAM


E147578E01


INSPECTION PROCEDURE

1.READ VALUE USING TECHSTREAM (EVAPORATOR FIN THERMISTOR)
  1. Use the Data List to check if the evaporator fin thermistor is functioning properly.

    Air Conditioner 
    Tester Display
    Measurement Item / Range
    Normal Condition
    Diagnostic Note
    Evaporator Fin Thermistor
    Evaporator fin thermistor /
    Min.: -29.7°C (-21.46°F)
    Max.: 59.55°C (139.19°F)
    Actual evaporator temperature is displayed
    Open in circuit: -29.7°C (-21.46°F)
    Short in circuit: 59.55°C (139.19°F)

    OK:
    The display is as specified in the normal condition.

    Result 
    Result
    Proceed to
    NG
    A
    OK (Checking from the PROBLEM SYMPTOMS TABLE)
    B
    OK (Checking from the DTC)
    C



B
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)

C
REPLACE AIR CONDITIONING AMPLIFIER (Click here)
A


2.INSPECT NO. 1 COOLER THERMISTOR (EVAPORATOR FIN THERMISTOR)

E146529E01

  1. Remove the No. 1 cooler thermistor (evaporator temperature sensor) connector (Click here).

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    -10°C (14°F)
    7.30 to 9.10 kΩ
    -5°C (23°F)
    5.65 to 6.95 kΩ
    0°C (32°F)
    4.40 to 5.35 kΩ
    5°C (41°F)
    3.40 to 4.15 kΩ
    10°C (50°F)
    2.70 to 3.25 kΩ
    15°C (59°F)
    2.14 to 2.58 kΩ
    20°C (68°F)
    1.71 to 2.05 kΩ
    25°C (77°F)
    1.38 to 1.64 kΩ
    30°C (86°F)
    1.11 to 1.32 kΩ

    NOTICE:
    1. Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
    2. When measuring, the sensor temperature must be the same as the ambient temperature.

    HINT:
    As the temperature increases, the resistance decreases (see the graph).



NG
REPLACE NO. 1 COOLER THERMISTOR (EVAPORATOR FIN THERMISTOR) (Click here)
OK


3.REPAIR OR REPLACE AIR CONDITIONING HARNESS
  1. Repair or replace the air conditioning harness.


NEXT


4.CHECK FOR DTC
  1. Clear the DTC (Click here).

  1. Check for DTC (Click here).

    OK:
    DTC is not output.



NG
REPLACE AIR CONDITIONING AMPLIFIER (Click here)
OK

END