ACCESSORY METER > REMOVAL |
| 1. REMOVE INSTRUMENT PANEL SUB-ASSEMBLY |
for Column Shift Type:
Remove the instrument panel (Click here).
for Floor Shift Type:
Remove the instrument panel (Click here).
| 2. REMOVE NO. 1 HEATER TO REGISTER DUCT WITH NO. 2 HEATER TO REGISTER DUCT |
Remove the 5 screws and duct.

| 3. REMOVE NO. 2 SIDE DEFROSTER NOZZLE DUCT |
![]() |
Remove the 2 screws.
Detach the claw and remove the duct.
| 4. REMOVE NO. 3 INSTRUMENT PANEL REGISTER ASSEMBLY |
![]() |
Remove the 3 screws and register.
| 5. REMOVE NO. 1 SIDE DEFROSTER NOZZLE DUCT |
![]() |
Remove the 2 screws.
Detach the claw and remove the duct.
| 6. REMOVE DEFROSTER NOZZLE ASSEMBLY |
![]() |
Remove the 3 screws and nozzle.
| 7. REMOVE ACCESSORY METER ASSEMBLY |
![]() |
Disconnect the accessory meter connector.
Remove the 3 screws and accessory meter.