Home › RESTRAINTS › SUPPLEMENTAL RESTRAINT SYSTEM › AIRBAG SYSTEM

DTC    B1661/44    Roll Over Cut Off Indicator Malfunction

for Preparation Click here


DESCRIPTION

The RSCA OFF switch is a mechanism that operates both right and left side of the curtain shield airbag and the front seat outer belt when the center airbag sensor detects a roll-over.
The RSCA OFF indicator is installed in the combination meter.
If the RSCA OFF switch is operated, the indicator comes on to inform the driver that the roll-over detection system is not working.
The initial setting of the roll-over detection system is on. It automatically operates every time the ignition switch is turned ON.

DTC Code
DTC Detection Condition
Trouble Area
B1661/44
  1. The center airbag sensor receives an open signal or short to ground in the RSCA OFF indicator circuit.
  2. RSCA OFF indicator malfunction
  3. Center airbag sensor malfunction
  1. Combination meter assembly
  2. Center airbag sensor assembly
  3. Instrument panel wire

WIRING DIAGRAM


C158887E03


INSPECTION PROCEDURE

NOTICE:
  1. After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) battery terminal notices before proceeding with work (Click here).
  2. When disconnecting the cable from the negative (-) battery terminal while performing repairs, some systems need to be initialized after the cable is reconnected (Click here).

1.CHECK COMBINATION METER (SOURCE VOLTAGE)
C161126E03
  1. Turn the ignition switch off.

  1. Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.

  1. Remove the combination meter with the connector connected.

  1. Disconnect the connector from the center airbag sensor.

  1. Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.

  1. Turn the ignition switch to ON.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    J28-6 (SW) - Body ground
    Ignition switch ON
    11 to 14 V



NG
GO TO METER / GAUGE SYSTEM (Click here)
OK


2.CHECK INSTRUMENT PANEL WIRE (CENTER AIRBAG SENSOR - COMBINATION METER AND BODY GROUND)
C158889E07
  1. Turn the ignition switch off.

  1. Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.

  1. Disconnect the connector from the center airbag sensor and combination meter.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    J28-6 (SW) - J46-18 (RMIL)
    Always
    Below 1 Ω
    J28-6 (SW) - Body ground
    Always
    1 MΩ or higher

  1. Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.

  1. Turn the ignition switch to ON.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    J28-6 (SW) - Body ground
    Ignition switch ON
    Below 1 V



NG
REPLACE INSTRUMENT PANEL WIRE
OK


3.INSPECT RSCA OFF SWITCH
C161127E02
  1. Turn the ignition switch off.

  1. Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.

  1. Remove the RSCA OFF switch.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    4 (SW) - 1 (E)
    RSCA OFF switch is in on position
    Below 1 Ω
    4 (SW) - 1 (E)
    RSCA OFF switch is in off position
    1 MΩ or higher



NG
REPLACE RSCA OFF SWITCH
OK


4.CHECK INSTRUMENT PANEL WIRE (CENTER AIRBAG SENSOR - RSCA OFF SWITCH AND BODY GROUND)
C161128E04
  1. Turn the ignition switch off.

  1. Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.

  1. Disconnect the connector from the center airbag sensor and RSCA OFF switch.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    J46-24 (RMSW) - J38-4 (SW)
    Always
    Below 1 Ω
    J38-4 (SW) - Body ground
    Always
    1 MΩ or higher
    J38-1 (E) - Body ground
    Always
    Below 1 Ω

  1. Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.

  1. Turn the ignition switch to ON.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    J38-4 (SW) - Body ground
    Ignition switch ON
    Below 1 V
    J38-1 (E) - Body ground

    Result 
    Result
    Proceed to
    NG
    A
    OK (for Column Shift Type)
    B
    OK (for Floor Shift Type)
    C



A
REPLACE INSTRUMENT PANEL WIRE

B
REPLACE CENTER AIRBAG SENSOR ASSEMBLY (Click here)
C

REPLACE CENTER AIRBAG SENSOR ASSEMBLY (Click here)