Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System)

DTC    B1423/23    Pressure Sensor Circuit

for Preparation Click here


DESCRIPTION

This DTC is output when refrigerant pressure is extremely low (196 kPa (2.0 kgf/cm2, 28 psi) or less) or extremely high (3140 kPa (32.0 kgf/cm2, 455 psi) or more). The pressure switch, which is installed on the pipe of the high pressure side to detect refrigerant pressure, outputs a refrigerant pressure signal to the air conditioning amplifier.
The air conditioning amplifier controls the compressor according to the sensor characteristic.

HINT:
Be sure to check the refrigerant volume first when this DTC is output because this DTC can also be output if there is no refrigerant in the system.


DTC Code
DTC Detection Condition
Trouble Area
B1423/23
Open or short in pressure switch circuit
  1. Air conditioning pressure switch
  2. Harness or connector
  3. Air conditioning amplifier

WIRING DIAGRAM


B159038E11


INSPECTION PROCEDURE

HINT:
Be sure to check the refrigerant volume first when this DTC is output because this DTC can also be output if there is no refrigerant in the system.

1.CHECK HARNESS OR CONNECTOR (AIR CONDITIONING PRESSURE SWITCH - AIR CONDITIONING AMPLIFIER AND BODY GROUND)
E146628E02
  1. Disconnect the A20 air conditioning pressure switch connector.

  1. Disconnect the J19 air conditioning amplifier connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    A20-1 (+S) - J19-9 (PSW)
    Always
    Below 1 Ω
    A20-1 (+S) or J19-9 (PSW) - Body ground
    Always
    10 kΩ or higher
    A20-2 (-S) - Body ground
    Always
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


2.CHECK AIR CONDITIONING PRESSURE SWITCH
E146630E02
  1. Set the manifold gauge set.

  1. Disconnect the A20 air conditioning pressure switch connector.

  1. Run the engine at approximately 2000 rpm.

  1. Set the blower speed control switch to the HI position.

  1. Set the temperature control level to the MAX. COOL position.

  1. Turn the A/C switch ON.



  1. Check the switch operation.

    1. Connect the positive (+) lead from an ohmmeter to terminal 1 (+S) and the negative (-) lead to terminal 2 (-S).



    2. Measure the resistance between the terminals when refrigerant pressure is changed as shown in the illustration.


      E146631E01

      OK:
      Resistance varies as shown in the illustration.

      Result 
      Result
      Proceed to
      NG
      A
      OK (Checking from the PROBLEM SYMPTOMS TABLE)
      B
      OK (Checking from the DTC)
      C



B
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)

C
REPLACE AIR CONDITIONING AMPLIFIER (Click here)
A

REPLACE AIR CONDITIONING PRESSURE SWITCH (Click here)