89421B
1.INSPECT MANIFOLD ABSOLUTE PRESSURE SENSOR
Check the resistance.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 4 (THA) - 2 (E2) | -20°C (-4°F) | 14.6 to 17.8 kΩ |
| 4 (THA) - 2 (E2) | 20°C (68°F) | 2.21 to 2.69 kΩ |
| 4 (THA) - 2 (E2) | 80°C (176°F) | 0.29 to 0.354 kΩ |
If the result is not as specified, replace the manifold absolute pressure sensor.