Perform "Inspection After Repairs" after replacing the spark plug or ignition coil assembly (See page Engine / Hybrid System>1UR-FE ENGINE CONTROL>SFI SYSTEM>INITIALIZATION).
19100P
1.INSTALL SPARK PLUG
Perform "Inspection After Repairs" after replacing the spark plug (See page Engine / Hybrid System>1UR-FE ENGINE CONTROL>SFI SYSTEM>INITIALIZATION).
Using a 16 mm plug wrench, install the 8 spark plugs.
19500
2.INSTALL IGNITION COIL ASSEMBLY
Perform "Inspection After Repairs" after replacing the ignition coil assembly (See page Engine / Hybrid System>1UR-FE ENGINE CONTROL>SFI SYSTEM>INITIALIZATION).
for Bank 1:
Install the 4 ignition coil assemblies with the 4 bolts.
Connect the 4 ignition coil connectors.
Attach the 3 wire harness clamps.
for Bank 2:
Install the 4 ignition coil assemblies with the 4 bolts.
Attach the 2 wire harness clamps and connect the 4 ignition coil connectors.
Connect the water by-pass pipe with the 2 bolts.
Attach the engine wire harness clamp.
17700
3.INSTALL AIR CLEANER ASSEMBLY
Install the air cleaner assembly with the 2 bolts.
Tighten the hose clamp.
Connect the ventilation hose and vacuum hose.
Attach the clamp and connect the mass air flow meter connector.
11209