Home › Engine / Hybrid System › 1UR-FE IGNITION › IGNITION COIL AND SPARK PLUG
RM27M0U _51 Engine / Hybrid System _049117 1UR-FE IGNITION _0234083 IGNITION COIL AND SPARK PLUG A

1UR-FE IGNITION  IGNITION COIL AND SPARK PLUG  INSTALLATION  


CAUTION / NOTICE / HINT

HINT:

Perform "Inspection After Repairs" after replacing the spark plug or ignition coil assembly (See page Engine / Hybrid System>1UR-FE ENGINE CONTROL>SFI SYSTEM>INITIALIZATION).


PROCEDURE

Hide 19100P 1.INSTALL SPARK PLUG

HINT:

Perform "Inspection After Repairs" after replacing the spark plug (See page Engine / Hybrid System>1UR-FE ENGINE CONTROL>SFI SYSTEM>INITIALIZATION).


a.

Using a 16 mm plug wrench, install the 8 spark plugs.

Torque:
21 N*m (214 kgf*cm, 15 ft.*lbf)


Hide 19500 2.INSTALL IGNITION COIL ASSEMBLY

HINT:

Perform "Inspection After Repairs" after replacing the ignition coil assembly (See page Engine / Hybrid System>1UR-FE ENGINE CONTROL>SFI SYSTEM>INITIALIZATION).


a.

for Bank 1:

i.

Install the 4 ignition coil assemblies with the 4 bolts.

Torque:
10 N*m (102 kgf*cm, 7 ft.*lbf)


ii.

Connect the 4 ignition coil connectors.


iii.

Attach the 3 wire harness clamps.



b.

for Bank 2:

i.

Install the 4 ignition coil assemblies with the 4 bolts.

Torque:
10 N*m (102 kgf*cm, 7 ft.*lbf)


ii.

Attach the 2 wire harness clamps and connect the 4 ignition coil connectors.


iii.

Connect the water by-pass pipe with the 2 bolts.

Torque:
18 N*m (184 kgf*cm, 13 ft.*lbf)


iv.

Attach the engine wire harness clamp.



Hide 17700 3.INSTALL AIR CLEANER ASSEMBLY

a.

Install the air cleaner assembly with the 2 bolts.

Torque:
5.0 N*m (51 kgf*cm, 44 in.*lbf)


b.

Tighten the hose clamp.

Torque:
4.0 N*m (41 kgf*cm, 35 in.*lbf)


c.

Connect the ventilation hose and vacuum hose.


d.

Attach the clamp and connect the mass air flow meter connector.