84222F
1.INSPECT TRANSFER INDICATOR SWITCH
Measure the resistance according to the value(s) in the table below.
24.63 to 24.89 mm (0.970 to 0.979 in.)
23.85 to 24.26 mm (0.939 to 0.955 in.)
21.89 to 22.40 mm (0.862 to 0.881 in.)
| *a | Switch Condition A (4HI Position) |
| *b | Switch Condition B (Not 4HI / Not 4LO Position) |
| *c | Switch Condition C (4LO Position) |
| *d | Ground Position |
| *e | Component without harness connected
(Transfer Indicator Switch) |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 1 (H4) - Case GND | Switch Condition A (4HI Position) | 10 kΩ or higher |
| 2 (L4) - Case GND | 10 kΩ or higher | |
| 1 (H4) - Case GND | Switch Condition B (4HI to 4LO Position) | Below 1 Ω |
| 2 (L4) - Case GND | 10 kΩ or higher | |
| 1 (H4) - Case GND | Switch Condition C (4LO Position) | Below 1 Ω |
| 2 (L4) - Case GND | Below 1 Ω |
If the resistance is not as specified, replace the transfer indicator switch.
The ground is the nut of the transfer indicator switch (connecting surface with the transfer case).