Shifting from 1st to 6th is performed in combination with ON and OFF operation of the shift solenoid valves SL1, SL2, S1, S2, S3, S4 and SR, which are controlled by the ECM. If an open or short circuit occurs in any of the shift solenoid valves, the ECM controls the remaining normal shift solenoid valves to allow the vehicle to be operated safely. Also, the ECM stops sending the current to the open or short circuited solenoid (See page Drivetrain>AB60F AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSMISSION SYSTEM>FAIL-SAFE CHART).
| DTC Code | DTC Detection Condition | Trouble Area |
|---|---|---|
| P0976 | ECM detects short in solenoid valve S2 circuit 2 times when solenoid valve S2 is operated (1 trip detection logic) | ·
Short in shift solenoid valve S2 circuit ·
Shift solenoid valve S2 ·
ECM |
| P0977 | ECM detects open in solenoid valve S2 circuit 2 times when solenoid valve S2 is not operated (1 trip detection logic) | ·
Open in shift solenoid valve S2 circuit ·
Shift solenoid valve S2 ·
ECM |
These DTCs indicate an open or short in the shift solenoid valve S2 circuit. When there is an open or short circuit in any shift solenoid valve circuit, the ECM detects the problem, illuminates the MIL and stores the DTC. When the shift solenoid valve S2 is ON, if its resistance is 8 Ω or less, the ECM determines there is a short in the shift solenoid valve S2 circuit.
When the shift solenoid valve S2 is OFF, if its resistance is 100 kΩ or more, the ECM determines there is an open in the shift solenoid valve S2 circuit (See page Drivetrain>AB60F AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSMISSION SYSTEM>FAIL-SAFE CHART).
| Related DTCs | P0976: Shift solenoid valve S2/Range check (Low resistance)
P0977: Shift solenoid valve S2/Range check (High resistance) |
| Required sensors/Components | Shift solenoid valve S2 |
| Frequency of operation | Continuous |
| Duration | 0.128 seconds or more |
| MIL operation | Immediately |
| Sequence of operation | None |
| The monitor will run whenever the following DTCs are not present | None |
| Battery voltage | 8 V or more |
| Ignition switch | ON |
| Starter | OFF |
| Command to shift solenoid valve S2 | ON |
| Command to shift solenoid valve S2 | OFF |
| Shift solenoid valve S2 resistance | 8 Ω or less |
| Shift solenoid valve S2 resistance | 100 kΩ or more |
| Shift solenoid valve S2 resistance | 11 to 15 Ω at 20°C (68°F) |
Perform the universal trip to clear permanent DTCs (See page Drivetrain>AB60F AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSMISSION SYSTEM>DTC CHECK / CLEAR).
The shift solenoid valve S2 is turned ON/OFF normally when the shift lever is on D:
| ECM gear shift command | 1st | 2nd | 3rd | 4th | 5th | 6th |
| Shift solenoid valve S2 | ON | ON | OFF | OFF | OFF | ON |
Disconnect the D63 No. 1 transmission wire connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 15 (S2) - Body ground | 20°C (68°F) | 11 to 15 Ω |
OK
NG
Disconnect the D74 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| D74-6 (S2) - Body ground | 20°C (68°F) | 11 to 15 Ω |
| Result | Proceed to |
|---|---|
| NG | A |
| OK (for 3UR-FE) | B |
| OK (for 3UR-FBE) | C |
A
B
C
Remove shift solenoid valve S2.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Shift solenoid valve S2 connector terminal - Shift solenoid valve S2 body | 20°C (68°F) | 11 to 15 Ω |
Connect the battery's positive (+) lead to the terminal of the solenoid valve connector, and the negative (-) lead to the solenoid valve body. Then check that the valve moves and makes an operating noise.
Valve moves and makes an operating noise.
OK
NG