Home › Drivetrain › AB60F AUTOMATIC TRANSMISSION / TRANSAXLE › AUTOMATIC TRANSMISSION SYSTEM
RM27M0U _52 Drivetrain _049125 AB60F AUTOMATIC TRANSMISSION / TRANSAXLE _0234142 AUTOMATIC TRANSMISSION SYSTEM C

AB60F AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSMISSION SYSTEM  P2759  Torque Converter Clutch Pressure Control Solenoid Control Circuit Electrical (Shift Solenoid Valve SLU)  


DESCRIPTION

The amount of current flow to the solenoid is controlled by the ECM. During the lock-up operation, if the current increases, the lock-up hydraulic pressure increases.

C221407E01
4.729,2.135 5.031,1.188 5.031,1.188 5.094,1.188 true 4.969,2.323 5.125,2.688 5.125,2.688 5.188,2.688 true 5.76,2.396 5.917,2.688 5.917,2.688 5.979,2.688 true 6.031,2.594 6.917,2.813 0.885,0.219 10 false Solenoid Coil 0.135,0.688 1.385,0.906 1.25,0.219 10 false Hydraulic Pressure 2.573,3.01 3.135,3.229 0.563,0.219 10 false Current 5.24,2.615 5.771,2.833 0.531,0.219 10 false Sleeve 5.167,1.104 6.01,1.323 0.844,0.219 10 false Spool Valve

DTC Code DTC Detection Condition Trouble Area
P2759 Open or short is detected in shift solenoid valve SLU circuit for 1 second or more while driving (1 trip detection logic)
·

Open or short in shift solenoid valve SLU circuit

·

Shift solenoid valve SLU

·

ECM



MONITOR DESCRIPTION

When an open or short in a shift solenoid valve SLU circuit is detected, the ECM determines that there is a malfunction. The ECM will illuminate the MIL and store the DTC.

MONITOR STRATEGY

Related DTCs P2759: Shift solenoid valve SLU/Range check
Required sensors/Components Shift solenoid valve SLU
Frequency of operation Continuous
Duration 1 second
MIL operation Immediately
Sequence of operation None

TYPICAL ENABLING CONDITIONS

The monitor will run whenever the following DTCs are not present None
Ignition switch ON
Starter OFF
Solenoid current cut status Not cut
Battery voltage 11 V or more

TYPICAL MALFUNCTION THRESHOLDS

Solenoid status from solenoid driver MIC Fail

COMPONENT OPERATING RANGE

Output signal duty Less than 100%

WIRING DIAGRAM

C352872E08
0.792,1.385 0.948,1.583 0.156,0.198 10 false 2 0.802,2.198 0.958,2.396 0.156,0.198 10 false 1 2.333,2.323 2.719,2.51 0.385,0.188 10 false SLU- 2.771,1.333 2.927,1.531 0.156,0.198 10 false 12 2.792,2.542 2.948,2.74 0.156,0.198 10 false 4 5.438,1.323 5.594,1.521 0.156,0.198 10 false 10 5.458,2.531 5.615,2.729 0.156,0.198 10 false 11 2.333,1.104 2.719,1.292 0.385,0.188 10 false SLU+ 1.104,1.802 2.708,2 1.604,0.198 10 false Shift Solenoid Valve SLU 5.729,1.208 6.115,1.396 0.385,0.188 10 false SLU+ 5.729,2.427 6.115,2.615 0.385,0.188 10 false SLU- 0.5,2.969 0.885,3.156 0.385,0.188 10 false D63 0.5,3.135 2.104,3.313 1.604,0.177 10 false No. 1 Transmission Wire 5.813,3.24 6.198,3.427 0.385,0.188 10 false D74 5.813,3.438 6.198,3.625 0.385,0.188 10 false ECM

CAUTION / NOTICE / HINT

NOTICE:

Perform the universal trip to clear permanent DTCs (See page Drivetrain>AB60F AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSMISSION SYSTEM>DTC CHECK / CLEAR).


PROCEDURE

1.INSPECT NO. 1 TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLU)
a.
C159421E15
1.235,2.631 1.669,2.776 0.434,0.145 10 SLU+ 0.058,0.046 2.640,0.413 2.582,0.367 10 Component without harness connected: (No. 1 Transmission Wire) 1.963,2.631 2.400,2.776 0.437,0.145 10 SLU- 1.731,2.024 1.472,2.592 false 1.798,1.804 2.103,2.592 false

Disconnect the D63 No. 1 transmission wire connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard resistance:
Tester Connection Condition Specified Condition
12 (SLU+) - 4 (SLU-) 20°C (68°F) 5.0 to 5.6 Ω
12 (SLU+) - Body ground Always 10 kΩ or higher
4 (SLU-) - Body ground Always 10 kΩ or higher




OK

2.CHECK HARNESS AND CONNECTOR (NO. 1 TRANSMISSION WIRE - ECM)

NG

3.INSPECT SHIFT SOLENOID VALVE SLU
2.CHECK HARNESS AND CONNECTOR (NO. 1 TRANSMISSION WIRE - ECM)
U152240E02
0.854,2.896 1.281,1.667 true 1.781,2.896 1.354,1.667 true 0.063,0.063 2.469,0.427 2.406,0.365 10 false Front view of wire harness connector: (to ECM) 1.583,1.042 1.958,1.271 0.375,0.229 10 false D74 1.469,2.906 2.177,3.104 0.708,0.198 10 false 11 (SLU-) 0.396,2.917 1.104,3.115 0.708,0.198 10 false 10 (SLU+)

a.

Disconnect the D74 ECM connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard resistance:
Tester Connection Condition Specified Condition
D74-10 (SLU+) - D74-11 (SLU-) 20°C (68°F) 5.0 to 5.6 Ω
D74-10 (SLU+) - Body ground Always 10 kΩ or higher
D74-11 (SLU-) - Body ground Always 10 kΩ or higher


Result
Result Proceed to
NG A
OK (for 3UR-FE) B
OK (for 3UR-FBE) C



A

REPAIR OR REPLACE HARNESS OR CONNECTOR

B

C

3.INSPECT SHIFT SOLENOID VALVE SLU
a.

Remove shift solenoid valve SLU.


C351967E03
1.125,0.99 1.531,1.25 true 2.281,1 1.885,1.25 true 2.281,2.979 1.885,3.229 true 1.125,2.969 1.531,3.229 true 0.063,0.063 2.5,0.406 2.438,0.344 10 false Component without harness connected: (Shift Solenoid Valve SLU) 1,0.906 1.104,1.104 0.104,0.198 10 false 2 2.313,0.917 2.417,1.115 0.104,0.198 10 false 1 1.01,2.865 1.115,3.063 0.104,0.198 10 false 2 2.313,2.896 2.417,3.094 0.104,0.198 10 false 1 1.271,4.344 1.49,4.542 0.219,0.198 10 false (+) 1.99,4.344 2.156,4.542 0.167,0.198 10 false (-)

b.

Measure the resistance according to the value(s) in the table below.

Standard resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 5.0 to 5.6 Ω



c.

Connect the battery's positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector. Then check that the valve moves and makes an operating noise.

OK:

Valve moves and makes an operating noise.




OK

REPAIR OR REPLACE NO. 1 TRANSMISSION WIRE

NG