Refer to DTC P0894 (See page Drivetrain>AB60F AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSMISSION SYSTEM>P0894).
| DTC Code | DTC Detection Condition | Trouble Area |
|---|---|---|
| P2716 | Open or short is detected in shift solenoid valve SLT circuit for 1 second or more while driving (1 trip detection logic) | ·
Open or short in shift solenoid valve SLT circuit ·
Shift solenoid valve SLT ·
ECM |
When an open or short in the shift solenoid valve SLT circuit is detected, the ECM interprets this as a fault. The ECM will turn on the MIL and store the DTC.
| Related DTCs | P2716: Shift solenoid valve SLT/Range check |
| Required sensors/Components | Shift solenoid valve SLT |
| Frequency of operation | Continuous |
| Duration | 1 second |
| MIL operation | Immediately |
| Sequence of operation | None |
| The monitor will run whenever the following DTCs are not present | None |
| Solenoid current cut status | Not cut |
| Battery voltage | 11 V or more |
| Ignition switch | ON |
| Starter | OFF |
| Solenoid voltage monitor signal from solenoid driver MIC | No signal |
| Output signal duty | Less than 100% |
Perform the universal trip to clear permanent DTCs (See page Drivetrain>AB60F AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSMISSION SYSTEM>DTC CHECK / CLEAR).
Disconnect the D63 No. 1 transmission wire connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 13 (SLT+) - 5 (SLT-) | 20°C (68°F) | 5.0 to 5.6 Ω |
| 13 (SLT+) - Body ground | Always | 10 kΩ or higher |
| 5 (SLT-) - Body ground | Always | 10 kΩ or higher |
OK
NG
Disconnect the D74 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| D74-9 (SLT+) - D74-8 (SLT-) | 20°C (68°F) | 5.0 to 5.6 Ω |
| D74-9 (SLT+) - Body ground | Always | 10 kΩ or higher |
| D74-8 (SLT-) - Body ground | Always | 10 kΩ or higher |
| Result | Proceed to |
|---|---|
| NG | A |
| OK (for 3UR-FE) | B |
| OK (for 3UR-FBE) | C |
A
B
C
Remove shift solenoid valve SLT.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 20°C (68°F) | 5.0 to 5.6 Ω |
Connect the battery's positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector. Then check that the valve moves and makes an operating noise.
Valve moves and makes an operating noise.
OK
NG