Home › Drivetrain › AB60E AUTOMATIC TRANSMISSION / TRANSAXLE › AUTOMATIC TRANSMISSION SYSTEM
RM27M0U _52 Drivetrain _049126 AB60E AUTOMATIC TRANSMISSION / TRANSAXLE _0234159 AUTOMATIC TRANSMISSION SYSTEM C

AB60E AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSMISSION SYSTEM  P0778  Pressure Control Solenoid "B" Electrical (Shift Solenoid Valve SL2)  


DESCRIPTION

Shifting from 1st to 5th is performed in combination with the ON and OFF operation of the shift solenoid valves SL1, SL2, S1, S2, S3, S4 and SR, which are controlled by the ECM. If an open or short circuit occurs in the shift solenoid valves, the ECM controls the remaining normal shift solenoid valves to allow the vehicle to be operated safely (See page Drivetrain>AB60E AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSMISSION SYSTEM>FAIL-SAFE CHART).

DTC Code DTC Detection Condition Trouble Area
P0778 The ECM checks for an open or short in the shift solenoid valve SL2 circuit while driving and shifting gears (1 trip detection logic)
Output signal duty ratio equals to 100%
HINT:

SL2 output signal duty ratio is less than 100% under normal condition


·

Open or short in shift solenoid valve SL2 circuit

·

Shift solenoid valve SL2

·

ECM



MONITOR DESCRIPTION

This DTC indicates an open or short in the shift solenoid valve SL2 circuit. The ECM commands gear shifts by turning the shift solenoid valves ON/OFF. When there is an open or short circuit in any shift solenoid valve circuit, the ECM detects the problem, illuminates the MIL and stores the DTC. Also, the ECM performs the fail-safe function and turns the other shift solenoid valves that are in good condition ON/OFF. In case of an open or short circuit, the ECM stops sending the current to the open or short circuited solenoid.

While driving and shifting gears, if the ECM detects an open or short in the shift solenoid valve SL2 circuit, the ECM determines there is a malfunction (See page Drivetrain>AB60E AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSMISSION SYSTEM>FAIL-SAFE CHART).

MONITOR STRATEGY

Related DTCs P0778: Shift solenoid valve SL2/Range check
Required sensors/Components Shift solenoid valve SL2
Frequency of operation Continuous
Duration 1 second
MIL operation Immediately
Sequence of operation None

TYPICAL ENABLING CONDITIONS

The monitor will run whenever the following DTCs are not present None
Ignition switch ON
Starter OFF
Solenoid current cut status Not cut
Battery voltage 11 V or more

TYPICAL MALFUNCTION THRESHOLDS

Solenoid status from solenoid driver MIC Fail

COMPONENT OPERATING RANGE

Output signal duty Less than 100%

WIRING DIAGRAM

C352872E03
0.792,1.385 0.948,1.583 0.156,0.198 10 false 1 0.802,2.198 0.958,2.396 0.156,0.198 10 false 2 2.333,2.323 2.719,2.51 0.385,0.188 10 false SL2- 2.771,1.333 2.927,1.531 0.156,0.198 10 false 2 2.792,2.542 2.948,2.74 0.156,0.198 10 false 4 5.438,1.323 5.594,1.521 0.156,0.198 10 false 12 5.458,2.531 5.615,2.729 0.156,0.198 10 false 13 2.333,1.104 2.719,1.292 0.385,0.188 10 false SL2+ 1.104,1.802 2.708,2 1.604,0.198 10 false Shift Solenoid Valve SL2 5.729,1.208 6.115,1.396 0.385,0.188 10 false SL2+ 5.729,2.427 6.115,2.615 0.385,0.188 10 false SL2- 0.5,2.969 0.885,3.156 0.385,0.188 10 false D64 0.5,3.135 2.104,3.313 1.604,0.177 10 false No. 2 Transmission Wire 5.813,3.24 6.198,3.427 0.385,0.188 10 false D74 5.813,3.438 6.198,3.625 0.385,0.188 10 false ECM

CAUTION / NOTICE / HINT

NOTICE:

Perform the universal trip to clear permanent DTCs (See page Drivetrain>AB60E AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSMISSION SYSTEM>DTC CHECK / CLEAR).


HINT:

The shift solenoid valve SL2 is turned ON/OFF normally when the shift lever is on D:

ECM gear shift command 1st 2nd 3rd 4th 5th 6th
Shift solenoid valve SL2 ON ON ON ON OFF OFF


PROCEDURE

1.INSPECT NO. 2 TRANSMISSION WIRE (SHIFT SOLENOID VALVE SL2)
a.
C161205E01
0.701,1.22 1.135,1.365 0.434,0.145 10 SL2+ 0.057,0.046 2.639,0.413 2.582,0.367 10 Component without harness connected: (No. 2 Transmission Wire) 0.701,2.395 1.138,2.540 0.437,0.145 10 SL2- 1.177,1.305 1.636,1.728 false 1.636,2.069 1.177,2.492 false

Disconnect the D64 No. 2 transmission wire connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard resistance:
Tester Connection Condition Specified Condition
2 (SL2+) - 4 (SL2-) 20°C (68°F) 5.0 to 5.6 Ω
2 (SL2+) - Body ground Always 10 kΩ or higher
4 (SL2-) - Body ground Always 10 kΩ or higher




OK

2.CHECK HARNESS AND CONNECTOR (NO. 2 TRANSMISSION WIRE - ECM)

NG

3.INSPECT SHIFT SOLENOID VALVE SL2
2.CHECK HARNESS AND CONNECTOR (NO. 2 TRANSMISSION WIRE - ECM)
U152238E02
1.021,2.885 1.448,1.656 true 1.958,2.896 1.531,1.667 true 0.063,0.052 2.469,0.417 2.406,0.365 10 false Front view of wire harness connector: (to ECM) 1.573,1.042 1.948,1.271 0.375,0.229 10 false D74 1.656,2.896 2.292,3.094 0.635,0.198 10 false 13 (SL2-) 0.583,2.906 1.26,3.104 0.677,0.198 10 false 12 (SL2+)

a.

Disconnect the D74 ECM connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard resistance:
Tester Connection Condition Specified Condition
D74-12 (SL2+) - D74-13 (SL2-) 20°C (68°F) 5.0 to 5.6 Ω
D74-12 (SL2+) - Body ground Always 10 kΩ or higher
D74-13 (SL2-) - Body ground Always 10 kΩ or higher


Result
Result Proceed to
NG A
OK (for 3UR-FE) B
OK (for 3UR-FBE) C



A

REPAIR OR REPLACE HARNESS OR CONNECTOR

B

C

3.INSPECT SHIFT SOLENOID VALVE SL2
a.

Remove shift solenoid valve SL2.


C351966E04
1.833,1.271 2.313,1.021 true 1.521,1.281 1.052,1.021 true 1.823,3.177 2.302,2.927 true 1.521,3.188 1.073,2.948 true 0.052,0.073 2.521,0.427 2.469,0.354 10 false Component without harness connected: (Shift Solenoid Valve SL2) 0.917,0.917 1.146,1.094 0.229,0.177 10 false 2 0.917,2.823 1.146,3 0.229,0.177 10 false 2 2.375,0.906 2.583,1.083 0.208,0.177 10 false 1 2.375,2.823 2.583,3 0.208,0.177 10 false 1 1.208,4.26 1.438,4.438 0.229,0.177 10 false (-) 2.021,4.271 2.25,4.448 0.229,0.177 10 false (+)

b.

Measure the resistance according to the value(s) in the table below.

Standard resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 5.0 to 5.6 Ω



c.

Connect the battery's positive (+) lead with a 21 W bulb to terminal 1 and the negative (-) lead to terminal 2 of the solenoid valve connector. Then check that the valve moves and makes an operating noise.

OK:

Valve moves and makes an operating noise.




OK

REPAIR OR REPLACE NO. 2 TRANSMISSION WIRE

NG