Home › Drivetrain › A760F AUTOMATIC TRANSMISSION / TRANSAXLE › TRANSMISSION WIRE
RM27M0U _52 Drivetrain _049127 A760F AUTOMATIC TRANSMISSION / TRANSAXLE _0234162 TRANSMISSION WIRE G

A760F AUTOMATIC TRANSMISSION / TRANSAXLE  TRANSMISSION WIRE  INSPECTION  


PROCEDURE

Hide 82125J 1.INSPECT TRANSMISSION WIRE (ATF TEMPERATURE SENSOR)

C210203E03
1.979,2.26 1.74,2.729 true 2.104,2.24 2.344,2.708 true 2,1.927 1.615,1.208 1.615,1.208 1.396,1.208 true 2.146,1.927 2.521,1.219 2.521,1.219 2.844,1.219 true 0.073,0.063 2.563,0.49 2.49,0.427 10 false Component without harness connected (Transmission Wire) 1.031,1.135 1.396,1.333 0.365,0.198 10 false OT2- 1.531,2.75 1.927,2.948 0.396,0.198 10 false OT2+ 2.885,1.146 3.198,1.344 0.313,0.198 10 false OT- 2.271,2.76 2.583,2.958 0.313,0.198 10 false OT+

a.

Measure the resistance according to the value(s) in the table below.

HINT:

If the resistance is out of the specified range at any of the ATF temperatures shown in the table below, the driveability of the vehicle may decrease.


Standard Resistance:
Tester Connection ATF Temperature Specified Condition
2 (OT-) - 13 (OT+) 10°C (50°F) 5 to 8 kΩ
2 (OT-) - 13 (OT+) 25°C (77°F) 2.5 to 4.5 kΩ
2 (OT-) - 13 (OT+) 110°C (230°F) 0.22 to 0.28 kΩ
3 (OT2-) - 14 (OT2+) 10°C (50°F) 5 to 8 kΩ
3 (OT2-) - 14 (OT2+) 25°C (77°F) 2.5 to 4.5 kΩ
3 (OT2-) - 14 (OT2+) 110°C (230°F) 0.22 to 0.28 kΩ


If the result is not as specified, replace the transmission wire.