The main body ECU controls the rear door lock motor to lock/unlock the rear door. This ECU applies current from terminal ACT+ to terminal ACT- to operate the motor to lock the door. It reverses the direction of the current flow to operate the motor to unlock the door.
Remove the rear door lock motor LH.
for Double Cab: (see page Vehicle Interior>DOOR LOCK>REAR DOOR LOCK(for Double Cab)>COMPONENTS)
for CrewMax: (see page Vehicle Interior>DOOR LOCK>REAR DOOR LOCK(for CrewMax)>REMOVAL)
Apply battery voltage and check operation of the door lock motor.
| Measurement Condition | Specified Condition |
|---|---|
| Battery positive (+) → Terminal 4 (L)
Battery negative (-) → Terminal 1 (UL) |
Lock |
| Battery positive (+) → Terminal 1 (UL)
Battery negative (-) → Terminal 4 (L) |
Unlock |
Remove the rear door lock motor RH.
for Double Cab: (see page Vehicle Interior>DOOR LOCK>REAR DOOR LOCK(for Double Cab)>COMPONENTS)
for CrewMax: (see page Vehicle Interior>DOOR LOCK>REAR DOOR LOCK(for CrewMax)>REMOVAL)
Apply battery voltage and check operation of the door lock motor.
| Measurement Condition | Specified Condition |
|---|---|
| Battery positive (+) → Terminal 4 (L)
Battery negative (-) → Terminal 1 (UL) |
Lock |
| Battery positive (+) → Terminal 1 (UL)
Battery negative (-) → Terminal 4 (L) |
Unlock |
| Result | Proceed to |
|---|---|
| OK (Rear door lock motor LH) | A |
| OK (Rear door lock motor RH) | B |
| NG (for Double Cab) | C |
| NG (for CrewMax) | D |
A
B
C
D
Disconnect the O10 door lock connector.
Disconnect the DC ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| O10-4 (L) - DC-24 (ACT+) | Always | Below 1 Ω |
| O10-1 (UL) - DC-23 (ACT-) | ||
| DC-24 (ACT+) - Body ground | Always | 10 kΩ or higher |
| DC-23 (ACT-) - Body ground |
OK
NG
Disconnect the O4 door lock connector.
Disconnect the DD ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| O4-4 (L) - DD-3 (ACT+) | Always | Below 1 Ω |
| O4-1 (UL) - DD-2 (ACT-) | ||
| DD-3 (ACT+) - Body ground | Always | 10 kΩ or higher |
| DD-2 (ACT-) - Body ground |
OK
NG