Home › Power Source / Network › M15A-FKS (BATTERY / CHARGING) › GENERATOR (for 100A Type)
RM3700E _57 Power Source / Network _092979 M15A-FKS BATTERY / CHARGING _0438222 GENERATOR(for 100A Type) A

M15A-FKS BATTERY / CHARGING  GENERATOR(for 100A Type)  INSTALLATION  


CAUTION / NOTICE / HINT

COMPONENTS (INSTALLATION)
A472805N03
1.594,0.99 2.677,1.156 1.083,0.167 0.5,2.323 1.198,2.49 0.698,0.167 0.25,2.719 1.01,2.885 0.76,0.167 1.552,0.948 2.719,1.198 1.167,0.25 6.5,0.24 6.833,0.24 false 6.5,0.583 6.813,0.583 false 4.531,1.01 4.844,1.01 false 2.24,2.719 2.552,2.719 false 1.042,1.865 1.354,1.865 false 2.094,1.625 2.427,1.625 false 1.01,2.802 1.26,2.802 false 1.146,2.802 1.146,3.073 1.146,3.073 1.583,3.073 false 0.844,2.125 0.844,2.323 false 1.26,1.438 1.427,1.073 1.427,1.073 1.594,1.073 false 2.594,2.542 2.875,2.896 0.281,0.354 18 false 1 2.521,1.49 2.802,1.844 0.281,0.354 18 false 1 0.865,1.688 1.146,2.042 0.281,0.354 18 false 1 4.948,0.865 5.229,1.219 0.281,0.354 18 false 2 6.302,0.052 6.583,0.406 0.281,0.354 18 false 3 6.313,0.417 6.594,0.771 0.281,0.354 18 false 4 1.656,0.99 2.906,1.271 1.25,0.281 8 false 9.8 (100, 87 in.*lbf) 0.583,2.333 1.281,2.646 0.698,0.313 8 false 10 (102, 7) 0.323,2.729 1.313,3.083 0.99,0.354 8 false 25 (255, 18) 1.344,2.865 1.625,3.219 0.281,0.354 10 false x2

Procedure Part Name Code
Z101186

Z101188

Z101187

1 GENERATOR ASSEMBLY 27020 - - -
2 V-RIBBED BELT 16361A - - -
3 CONNECT CABLE TO NEGATIVE AUXILIARY BATTERY TERMINAL - - - -
4 INITIALIZATION AFTER RECONNECTING AUXILIARY BATTERY TERMINAL - - - (Click here)

V111893

Tightening torque for "Major areas involving basic vehicle performance such as moving/turning/stopping" : N*m (kgf*cm, ft.*lbf)
V100146

N*m (kgf*cm, ft.*lbf): Specified torque

PROCEDURE

Hide 27020 1.INSTALL GENERATOR ASSEMBLY

a.
A459820

Torque:
25 N*m (255 kgf*cm, 18 ft.*lbf)


b.
A459819

Torque:
Bolt : 10 N*m (102 kgf*cm, 7 ft.*lbf)
Nut : 9.8 N*m (100 kgf*cm, 87 in.*lbf)


Hide 16361A 2.INSTALL V-RIBBED BELT

Hide 3.CONNECT CABLE TO NEGATIVE AUXILIARY BATTERY TERMINAL

Hide 4. INITIALIZATION AFTER RECONNECTING AUXILIARY BATTERY TERMINAL

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE

HINT:

When disconnecting and reconnecting the battery, there is an automatic learning function thatcompletes learning when the respective system is used.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART