Home › Audio / Visual / Telematics › PARK ASSIST / MONITORING › ULTRASONIC SENSOR (for Front) › 2020.08–2021.07
RM3700E _56 Audio / Visual / Telematics _093031 PARK ASSIST / MONITORING _0438550 ULTRASONIC SENSOR(for Front) A

PARK ASSIST / MONITORING  ULTRASONIC SENSOR(for Front)  REMOVAL  


CAUTION / NOTICE / HINT

COMPONENTS (REMOVAL)
E449718N01
5.802,2.99 5.667,2.99 5.667,2.99 5.604,2.771 false 5.385,1.677 5.719,1.677 false 4.635,1.135 4.969,1.135 false 3.75,0.292 3.917,0.292 3.917,0.292 4,0.625 false 2.885,0.25 3.01,0.25 3.01,0.25 3.208,0.625 false 1.531,5.177 1.531,4.844 false 5.948,2.177 6.281,2.177 false 1.469,5.198 1.75,5.552 0.281,0.354 18 false 1 6.344,2.01 6.625,2.365 0.281,0.354 18 false 3 6.073,2.927 6.271,3.177 0.198,0.25 10 false ● 6.198,2.875 6.479,3.229 0.281,0.354 18 false 4 5.781,1.521 6.063,1.875 0.281,0.354 18 false 2 5.031,0.969 5.313,1.323 0.281,0.354 18 false 2 3.583,0.135 3.865,0.49 0.281,0.354 18 false 3 2.552,0.198 2.75,0.448 0.198,0.25 10 false ● 2.677,0.125 2.958,0.479 0.281,0.354 18 false 4

Procedure Part Name Code
Z101186

Z101188

Z101187

1 FRONT BUMPER ASSEMBLY - - - -
2 FRONT CENTER ULTRASONIC SENSOR 89341L - - -
3 FRONT CORNER ULTRASONIC SENSOR 89341K - - -
4 FRONT CORNER ULTRASONIC SENSOR RETAINER 89347B (Click here) - -

● Non-reusable part - -

E463470N09
1.521,1.958 1.979,1.958 false 1.302,1.833 1.583,2.188 0.281,0.354 18 false 6

Procedure Part Name Code
Z101186

Z101188

Z101187

6 ULTRASONIC SENSOR CUSHION SET - (Click here) - -

CAUTION / NOTICE / HINT

The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed and installed, or replaced during ultrasonic sensor removal/installation are shown below.

Necessary Procedure After Parts Removed/Installed/Replaced
Replaced Part or Performed Procedure Necessary Procedure Effect/Inoperative Function When Necessary Procedures are not Performed Link
Ultrasonic sensor (Including removal and installation)
·

Ultrasonic sensor detection angle

·

Ultrasonic sensor detection angle registration


·

TOYOTA parking assist-sensor system

·

Parking support brake system


(Click here)

PROCEDURE

Hide 1.REMOVE FRONT BUMPER ASSEMBLY

Hide 89341L 2.REMOVE FRONT CENTER ULTRASONIC SENSOR

a.
E449653


b.

The illustration is for the LH side. The orientation for the RH side is the opposite of the LH side.


Hide 89341K 3.REMOVE FRONT CORNER ULTRASONIC SENSOR

a.
E449654


b.

The illustration is for the LH side. The orientation for the RH side is the opposite of the LH side.


Hide 89347B 4.REMOVE FRONT CORNER ULTRASONIC SENSOR RETAINER

Z101186

NOTICE:
·

Perform this procedure only when replacement of the front corner ultrasonic sensor retainer is necessary.

·

When removing the front corner ultrasonic sensor retainer, if the double-sided tape is difficult to remove, heat the front bumper assembly and front corner ultrasonic sensor retainer using a heat light.




a.
E449656C01
0.396,0.063 0.635,0.375 0.24,0.313 18 false i 3.688,0.052 3.875,0.406 0.188,0.354 18 false ii
V100145

Heated Area - -


i.

Heat the front bumper assembly and front corner ultrasonic sensor retainer using a heat light at the specified temperature for 3 to 5 minutes.

Heating Temperature:
Item Temperature
Front Bumper Assembly 40 to 60°C (104 to 140°F)
Front Corner Ultrasonic Sensor Retainer


CAUTION:
E306500C23
2.365,2 2.698,2 false 0.5,2.333 0.5,2.667 true 0.427,2.708 0.74,2.865 0.313,0.156 10 false *a 2.76,1.927 3.073,2.083 0.313,0.156 10 false *b
*a Heated Part
*b Heat Light


·

Do not touch the heat light and heated parts.

·

Touching the heat light may result in burns.

·

Touching heated parts for a long time may result in burns.



NOTICE:

Do not heat the front bumper assembly and front corner ultrasonic sensor retainer excessively.



ii.

Remove the front corner ultrasonic sensor retainer.



b.

The illustration is for the LH side. The orientation for the RH side is the opposite of the LH side.


Hide 5.REMOVE ULTRASONIC SENSOR CUSHION SET

Z101186

NOTICE:

Perform this procedure only when replacement of the ultrasonic sensor cushion set is necessary.



a.
E463471