| Procedure | Part Name Code |
|
|
|
|
|---|---|---|---|---|---|
| 1 | ULTRASONIC SENSOR CUSHION SET | - | ( )
|
- | - |
| ● | Non-reusable part | - | - |
1.INSTALL ULTRASONIC SENSOR CUSHION SET
|
|
89347B
2.INSTALL FRONT CORNER ULTRASONIC SENSOR RETAINER
|
|
| *a | Scribed Line | - | - |
|
Primer Application | - | - |
Clean the surface of the front bumper assembly.
1. Using a heat light, heat the front bumper assembly.
2. Remove any remaining double-sided tape from the front bumper assembly.
3. Wipe off any adhesive residue with cleaner.
Installing the front corner ultrasonic sensor retainer with some double-sided tape remaining may cause poor adhesion. Perform this procedure until the tape is sufficiently removed.
Make sure to use a cloth when removing. Using a screwdriver, etc., may cause damage and poor adhesion.
Cover the sensor installation hole with a 20 mm (0.787 in.) circular piece of tape.
Apply primer to front bumper assembly on the installation area of the front corner ultrasonic sensor retainer using a brush or felt.
Replace the brush or felt if it is dirty or has become hardened.
Keep any painted surface free from primer.
If the primer contacts a painted surface, it may leave light primer marks. Therefore, use protective tape when using liquid primer.
Do not touch surfaces to which primer has been applied until the front corner ultrasonic sensor retainer has been attached.
1. Let the primer dry sufficiently.
Do not touch applied surfaces until the primer is dry.
10 Minutes or more (at 23°C (73°F))
2. Confirm that the primer has completely dried by touching the front bumper assembly. Then remove the tape.
Remove the peeling paper of a new front corner ultrasonic sensor retainer trying not to touch the adhesional surface.
After removing the peeling paper, do not touch the surface of the tape with your fingers or cotton work gloves.
Align the front corner ultrasonic sensor retainer with front corner ultrasonic sensor with the scribed line on the front bumper assembly and install it as shown in the illustration.
Ensure that the front corner ultrasonic sensor tip is correctly inserted into the sensor installation hole of the front bumper assembly.
The application strength of the front corner ultrasonic sensor retainer will weaken if reapplied. If reapplication is necessary, be sure to replace it with a new one.
Apply pressure so that it does not lift up from the front bumper assembly.
Pushing force: 50 N (5.1 kgf) for 3 seconds
The illustration is for the LH side. The orientation for the RH side is the opposite of the LH side.
89341K
3.INSTALL FRONT CORNER ULTRASONIC SENSOR
89341L
4.INSTALL FRONT CENTER ULTRASONIC SENSOR
5.INSTALL FRONT BUMPER ASSEMBLY
6.PERFORM CALIBRATION