Refer to the description for DTC P0C7396.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0C7396
The inverter water pump assembly sends the inverter water pump speed (measured value) signal to the hybrid vehicle control ECU.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate | DTC Output from | Priority |
|---|---|---|---|---|---|---|---|
| P314A31 | Motor Electronics Coolant Pump "A" No Signal | The inverter water pump speed signal is not sent to the hybrid vehicle control ECU when the ignition switch is turned to ON (READY).*
(1 trip detection logic) |
·
Wire harness or connector ·
Hybrid vehicle control ECU ·
Inverter water pump assembly ·
INV W/P fuse ·
IGCT-MAIN fuse ·
IGCT relay |
Comes on | Master Warning: Comes on | Hybrid Control | A |
A malfunction (open, short to +B or short to ground) in the speed signal line from the inverter water pump assembly to the hybrid vehicle control ECU is detected.
A malfunction in the inverter water pump assembly power source circuit is detected.
A malfunction in the +B line is detected.
A malfunction in hybrid vehicle control ECU power source circuit is detected.
| DTC No. | Data List |
|---|---|
| P314A31 | ·
Inverter Water Pump Revolution ·
Inverter Water Pump Duty Ratio ·
Ready Signal |
| DTC No. | Active Test |
|---|---|
| P314A31 | Activate the Inverter Water Pump |
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>UTILITY
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the ignition switch off and wait for 2 minutes or more.
Turn the ignition switch to ON (READY) and wait for 2 minutes or more.
Enter the following menus: Powertrain / Hybrid Control / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE, perform driving pattern again.
Refer to the wiring diagram for DTC P0C7396.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0C7396
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P06881F
| Proceed to |
|---|
| NEXT |
NEXT
Make sure that the HV coolant level is above the low line of the inverter reserve tank.
Be sure to perform the inspection with the auxiliary battery voltage at 11 V or more.
When the inverter water pump assembly signal line (SWP - IWP) is open or its connection is faulty, the inverter water pump assembly is operated forcibly.
When the auxiliary battery voltage is low, the inverter water pump assembly may not operate.
Pre-procedure1
None.
Procedure1
Perform the "Activate the Inverter Water Pump" Active Test.
| Tester Display |
|---|
| Activate the Inverter Water Pump |
Touch the inverter water pump assembly and check that it is operating (vibrating).
The inverter water pump is operating (vibrating).
Perform the Active Test with the inverter coolant temperature between -15 and 65°C (5 to 149°F).
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Turn the ignition switch off.
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P056014
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>Cooling System
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check the condition (looseness, deterioration, etc.) of the wire to body ground for the inverter water pump assembly.
Pre-procedure1
Disconnect the A68 hybrid vehicle control ECU connector.
Disconnect the A59 inverter water pump assembly connector.
Procedure1
| *a | Front view of wire harness connector
(to Hybrid Vehicle Control ECU) |
| *b | Front view of wire harness connector
(to Inverter Water Pump Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A68,A59)Location & Routingewd_type=routing;type=c,c;code=A68,A59 Click Connector(A68)Instrument Panel>Engine Room Main Wire>Hybrid Vehicle Control ECUewd_type=component;type=c;code=A68;pinno=32 Click Connector(A59)Engine Compartment>Engine Room Main Wire>Inverter Water Pump Assembly (with Motor)ewd_type=component;type=c;code=A59;pinno=2 |
||
| A68-32 (NIWP) - A59-2 (NWP) | Ignition switch off | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A68,A59)Location & Routingewd_type=routing;type=c,c;code=A68,A59 Click Connector(A68)Instrument Panel>Engine Room Main Wire>Hybrid Vehicle Control ECUewd_type=component;type=c;code=A68;pinno=32 Click Connector(A59)Engine Compartment>Engine Room Main Wire>Inverter Water Pump Assembly (with Motor)ewd_type=component;type=c;code=A59;pinno=2 |
||
| A68-32 (NIWP) or A59-2 (NWP) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the A59 inverter water pump assembly connector.
Reconnect the A68 hybrid vehicle control ECU connector.
OK
NG
Pre-procedure1
Disconnect the A59 inverter water pump assembly connector.
Turn the ignition switch to ON.
Procedure1
Measure the voltage according to the value(s) in the table below.
| *a | Component with harness connected
(Hybrid Vehicle Control ECU) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A68,H44)Location & Routingewd_type=routing;type=c,c;code=A68,H44 Click Connector(A68)Instrument Panel>Engine Room Main Wire>Hybrid Vehicle Control ECUewd_type=component;type=c;code=A68;pinno=32 Click Connector(H44)Instrument Panel>Instrument Panel Wire / Speaker Wire>Hybrid Vehicle Control ECUewd_type=component;type=c;code=H44;pinno=15 |
||
| A68-32 (NIWP) - H44-15 (E1) | Ignition switch ON | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Turn the ignition switch off.
Reconnect the A59 inverter water pump assembly connector.
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P06881F
| Proceed to |
|---|
| NEXT |
NEXT
Be sure to perform the inspection with the auxiliary battery voltage at 11 V or more.
When the auxiliary battery voltage is low, the inverter water pump assembly may not operate.
Pre-procedure1
Perform the "Activate the Inverter Water Pump" Active Test.
| Tester Display |
|---|
| Activate the Inverter Water Pump |
Procedure1
Connect an oscilloscope between the hybrid vehicle control ECU terminals specified in the table below, and measure the waveform.
| *a | Component with harness connected
(Hybrid Vehicle Control ECU) |
- | - |
| Item | Content |
|---|---|
| Terminal | A68-32 (NIWP) - H44-15 (E1) |
| Equipment Setting | 5 V/DIV., 5 ms./DIV. |
| Condition | Ignition switch ON, during Active Test |
The period of the wavelength is 13 msec. or less.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Turn the ignition switch off.
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>Cooling System
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Pre-procedure1
Remove the IGCT relay from the No. 5 relay block assembly.
Disconnect the A59 inverter water pump assembly connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| *1 | No. 5 Relay Block Assembly | *2 | IGCT Relay Holder |
| *a | Front view of wire harness connector
(to Inverter Water Pump Assembly) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A59)Location & Routingewd_type=routing;type=c;code=A59 Click Connector(A59)Engine Compartment>Engine Room Main Wire>Inverter Water Pump Assembly (with Motor)ewd_type=component;type=c;code=A59;pinno=4 |
||
| A59-4 (+BWP) - 5 (IGCT relay holder) | Ignition switch off | Below 1 Ω |
Do not apply excessive force when using the probes of the tester to perform the inspection. If excessive force is used, the terminals will be damaged.
| *a | Example |
| *b | Shake Slightly |
| *c | Vibrate Slightly |
Connectors
Slightly shake the connector vertically and horizontally.
Wire Harness
Slightly shake the wire harness vertically and horizontally.
The connector joint and fulcrum of the vibration are the major areas that should be checked thoroughly.
No. 5 Relay Block Assembly
Apply slight vibration with a finger to the No. 5 relay block assembly and check whether a malfunction occurs.
INV W/P fuse
Apply slight vibration with a finger to the INV W/P fuse and check whether a malfunction occurs.
IGCT relay
Apply slight vibration with a finger to the IGCT relay and check whether a malfunction occurs.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the A59 inverter water pump assembly connector.
Install the IGCT relay.
OK
NG
Pre-procedure1
Disconnect the A59 inverter water pump assembly connector.
Procedure1
| *a | Front view of wire harness connector
(to Inverter Water Pump Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A59)Location & Routingewd_type=routing;type=c;code=A59 Click Connector(A59)Engine Compartment>Engine Room Main Wire>Inverter Water Pump Assembly (with Motor)ewd_type=component;type=c;code=A59;pinno=1 |
||
| A59-1 (GND) - Body ground | Ignition switch off | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the A59 inverter water pump assembly connector.
OK
NG
| Proceed to |
|---|
| NEXT |
NEXT
After replacing the inverter water pump assembly, add HV coolant and perform air bleeding.
Click hereGeneral>MAINTENANCE>COOLANT (for Inverter)>REPLACEMENT
| Proceed to |
|---|
| NEXT |
NEXT
Pre-procedure1
| *1 | No. 5 Relay Block Assembly |
| *2 | INV W/P Fuse |
Remove the INV W/P fuse from the No. 5 relay block assembly.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| INV W/P fuse | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Install the INV W/P fuse.
OK
NG
Check installation condition of the INV W/P fuse.
INV W/P fuse is installed correctly.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Pre-procedure1
Remove the INV W/P fuse from the No. 5 relay block assembly.
Remove the IGCT relay from the No. 5 relay block assembly.
Disconnect the A59 inverter water pump assembly connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| *1 | No. 5 Relay Block Assembly | *2 | INV W/P Fuse Holder |
| *3 | IGCT Relay Holder | - | - |
| *a | Front view of wire harness connector
(to Inverter Water Pump Assembly) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A59)Location & Routingewd_type=routing;type=c;code=A59 Click Connector(A59)Engine Compartment>Engine Room Main Wire>Inverter Water Pump Assembly (with Motor)ewd_type=component;type=c;code=A59;pinno=4 |
||
| 2 (INV W/P fuse holder) - A59-4 (+BWP) | Ignition switch off | Below 1 Ω |
| 1 (INV W/P fuse holder) - 5 (IGCT relay) | Ignition switch off | Below 1 Ω |
| 2 (INV W/P fuse holder) or A59-4 (+BWP) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
Do not apply excessive force when using the probes of the tester to perform the inspection. If excessive force is used, the terminals will be damaged.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the A59 inverter water pump assembly connector.
Install the IGCT relay.
Install the INV W/P fuse.
OK
NG
Pre-procedure1
| *1 | No. 5 Relay Block Assembly |
| *2 | INV W/P Fuse |
Remove the INV W/P fuse from the No. 5 relay block assembly.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| INV W/P fuse | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Install the INV W/P fuse.
OK
NG
Connect the inverter water pump assembly connector securely.
| Proceed to |
|---|
| NEXT |
NEXT
Check the terminals of the INV W/P fuse holder.
The terminals of the INV W/P fuse holder are not bent, loose or corroded.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Pre-procedure1
| *1 | No. 5 Relay Block Assembly |
| *2 | INV W/P Fuse |
Remove the INV W/P fuse from the No. 5 relay block assembly.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| INV W/P fuse | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Install the INV W/P fuse.
OK
NG
Pre-procedure1
| *1 | No. 5 Relay Block Assembly |
| *2 | INV W/P Fuse |
Remove the INV W/P fuse from the No. 5 relay block assembly.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| INV W/P fuse | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Install the INV W/P fuse.
OK
NG
Pre-procedure1
Disconnect the A59 inverter water pump assembly connector.
Procedure1
| *a | Front view of wire harness connector
(to Inverter Water Pump Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A59)Location & Routingewd_type=routing;type=c;code=A59 Click Connector(A59)Engine Compartment>Engine Room Main Wire>Inverter Water Pump Assembly (with Motor)ewd_type=component;type=c;code=A59;pinno=1 |
||
| A59-1 (GND) - Body ground | Ignition switch off | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the A59 inverter water pump assembly connector.
OK
NG
Check the terminals of the INV W/P fuse holder.
The terminals of the INV W/P fuse holder are not bent, loose or corroded.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| Proceed to |
|---|
| NEXT |
NEXT
After replacing the inverter water pump assembly, add HV coolant and perform air bleeding.
Click hereGeneral>MAINTENANCE>COOLANT (for Inverter)>REPLACEMENT
| Proceed to |
|---|
| NEXT |
NEXT
Pre-procedure1
| *1 | No. 5 Relay Block Assembly |
| *2 | INV W/P Fuse |
Remove the INV W/P fuse from the No. 5 relay block assembly.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| INV W/P fuse | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Install the INV W/P fuse.
OK
NG
| Proceed to |
|---|
| NEXT |
NEXT
Repair or replace the terminals of the INV W/P fuse holder.
| Proceed to |
|---|
| NEXT |
NEXT