MALFUNCTION DESCRIPTION
The hybrid vehicle control ECU detects a stuck closed malfunction of a system main relay on the HV battery positive (+) terminal side.
The cause of this malfunction may be one of the following:
Voltage sensor (VH) malfunction
Motor generator control ECU (MG ECU) malfunction
Communication (wire harness) malfunction
No. 1 traction battery device box assembly malfunction
Hybrid vehicle control ECU malfunction
No. 1 traction battery device box assembly malfunction
Low voltage wire harness malfunction
Low voltage connector malfunction
Refer to the description for DTC P0AE411.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0AE411
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate | DTC Output from | Priority |
|---|---|---|---|---|---|---|---|
| P0AA000 | Hybrid/EV Battery Positive Contactor Circuit Stuck Closed | Even the system main relay of HV battery positive (+) terminal side is turned off, the inverter voltage (VH) does not drop.
(1 trip detection logic) |
·
No. 1 traction battery device box assembly ·
Hybrid motor control inverter assembly ·
Hybrid vehicle control ECU ·
Wire harness or connector |
Does not come on | Master Warning: Comes on | Hybrid Control | A |
| DTC No. | Data List |
|---|---|
| P0AA000 | ·
Hybrid/EV Battery Voltage ·
VH-Voltage after Boosting ·
VL-Voltage before Boosting |
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>UTILITY
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the ignition switch off and wait for 2 minutes or more.
Turn the ignition switch to ON (READY) and wait for 3 minutes or more.
According to the display on the GTS, read the Data List and monitor the values of "Hybrid/EV Battery Voltage" and "VL-Voltage before Boosting" for 3 minutes. If the difference between "Hybrid/EV Battery Voltage" and "VL-Voltage before Boosting" is always less than 50 V, the vehicle has returned to normal.
Enter the following menus: Powertrain / Hybrid Control / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.
Refer to the wiring diagram for the HV Battery High-voltage Line Circuit.
Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly*
*: for AWD
Disconnecting the low voltage connector of the HV battery
To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.
After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
| *a | Without waiting for 10 minutes |
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly*. The voltage should be 0 V before beginning work.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly*.
*: for AWD
Make sure to insulate the high-voltage connectors and terminals of the HV battery with insulating tape after removing it.
If the HV battery stored without insulating the connectors and terminals, electric shock or fire may result.
After the ignition switch is turned off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY
When disconnecting and reconnecting the auxiliary battery
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART
If the DTCs are cleared or the cable is disconnected and reconnected to the negative (-) auxiliary battery terminal before performing repairs, turning the ignition switch to ON (READY) may cause a malfunction. Do not turn the ignition switch to ON (READY).
If DTC P0AA000 is output, the ignition switch cannot be turned to ON (READY).
Pre-procedure1
None.
Procedure1
Check for DTCs.
| Result | Proceed to |
|---|---|
| Only P0AA000 for Hybrid Control System is output | A |
| P0AA000 and DTCs other than the DTCs in the table below are output | B |
| P0AA000 and Microcomputer malfunction of Hybrid Control System DTCs in the table below are output | C |
| P0AA000 and Microcomputer malfunction of Motor generator control system DTCs in the table below are output | D |
| P0AA000 and Power source circuit malfunction of Motor generator control system DTCs in the table below are output | E |
| P0AA000 and Communication system malfunction of Hybrid Control System DTCs in the table below are output | F |
| P0AA000 and Sensor and actuator circuit malfunction of Hybrid Control System DTCs in the table below are output | G |
| P0AA000 and Sensor and actuator circuit malfunction of Motor generator control system DTCs in the table below are output | H |
| P0AA000 and System malfunction of Hybrid Control System DTCs in the table below are output | I |
| P0AA000 and System malfunction of Motor generator control system DTCs in the table below are output | J |
| System | Relevant DTC | |
|---|---|---|
| Hybrid Control System | P0AA000 | Hybrid/EV Battery Positive Contactor Circuit Stuck Closed |
| Malfunction Content | System | Relevant DTC | |
|---|---|---|---|
| Microcomputer malfunction | Hybrid control system | P060647 | Hybrid/EV Powertrain Control Module Processor Watchdog / Safety MCU Failure |
| P060687 | Hybrid/EV Powertrain Control Module Processor to Monitoring Processor Missing Message | ||
| P060A47 | Hybrid/EV Powertrain Control Module Monitoring Processor Watchdog / Safety MCU Failure | ||
| P060A87 | Hybrid/EV Powertrain Control Module Processor from Monitoring Processor Missing Message | ||
| P0A1B49 | Drive Motor "A" Control Module Internal Electronic Failure | ||
| P1C9E9F | Hybrid/EV System Reset Stuck Off | ||
| Motor generator control system | P0A1B1F | Generator Control Module Circuit Intermittent | |
| P0A1A47 | Generator Control Module Watchdog / Safety MC Failure | ||
| P0A1A49 | Generator Control Module Internal Electronic Failure | ||
| P1C2A1C | Generator A/D Converter Circuit Circuit Voltage Out of Range | ||
| P1C2A49 | Generator A/D Converter Circuit Internal Electronic Failure | ||
| P1C2B1C | Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range | ||
| P1C2B49 | Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure | ||
| P1CAC49 | Generator Position Sensor Internal Electronic Failure | ||
| P1CAD49 | Drive Motor "A" Position Sensor Internal Electronic Failure | ||
| P1CAF38 | Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect | ||
| P1CB038 | Drive Motor "A" Position Sensor REF Signal Frequency Incorrect | ||
| P313383 | Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect | ||
| P313386 | Communication Error from Generator to Drive Motor "A" Signal Invalid | ||
| P313387 | Communication Error from Generator to Drive Motor "A" Missing Message | ||
| Power source circuit malfunction | Motor generator control system | P06D61C | Generator Control Module Offset Power Circuit Voltage Out of Range |
| P06B01C | Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range | ||
| Communication system malfunction | Hybrid control system | P312387 | Lost Communication with Drive Motor Control Module "A" from Hybrid/EV Control Module Missing Message |
| Sensor and actuator circuit malfunction | Hybrid control system | P0AD911 | Hybrid/EV Battery Positive Contactor Circuit Short to Ground |
| P0AD915 | Hybrid/EV Battery Positive Contactor Circuit Short to Auxiliary Battery or Open | ||
| P0ADD11 | Hybrid/EV Battery Negative Contactor Circuit Short to Ground | ||
| P0ADD15 | Hybrid/EV Battery Negative Contactor Circuit Short to Auxiliary Battery or Open | ||
| P0AE411 | Hybrid/EV Battery Precharge Contactor Circuit Short to Ground | ||
| P0AE415 | Hybrid/EV Battery Precharge Contactor Circuit Short to Auxiliary Battery or Open | ||
| Motor generator control system | P0A3F16 | Drive Motor "A" Position Sensor Circuit Voltage Below Threshold | |
| P0A4B16 | Generator Position Sensor Circuit Voltage Below Threshold | ||
| P0A4B21 | Generator Position Sensor Signal Amplitude < Minimum | ||
| P0A4B22 | Generator Position Sensor Signal Amplitude > Maximum | ||
| P0C5013 | Drive Motor "A" Position Sensor Circuit "A" Circuit Open | ||
| P0C5016 | Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold | ||
| P0C5017 | Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold | ||
| P0C5A13 | Drive Motor "A" Position Sensor Circuit "B" Circuit Open | ||
| P0C5A16 | Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold | ||
| P0C5A17 | Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold | ||
| P0C6413 | Generator Position Sensor Circuit "A" Circuit Open | ||
| P0C6416 | Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold | ||
| P0C6417 | Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold | ||
| P0C6913 | Generator Position Sensor Circuit "B" Circuit Open | ||
| P0C6916 | Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold | ||
| P0C6917 | Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold | ||
| System malfunction | Hybrid control system | P0D2D1C | Drive Motor "A" Inverter Voltage Sensor Voltage Out of Range |
| P1C8349 | High Voltage Power Resource Circuit Voltage Sensor after Boosting Malfunction | ||
| P0C7600 | Hybrid/EV Battery System Discharge Time Too Long | ||
| Motor generator control system | P0D2D16 | Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Below Threshold | |
| P0D2D17 | Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold | ||
| P1CB69E | Drive Motor "A" Inverter Voltage Sensor (VH) Stuck On | ||
P0AA000 may be output as a result of the malfunction indicated by the DTCs above.
The chart above is listed in inspection order of priority.
Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
Post-procedure1
Turn the ignition switch off.
A
B
C
D
E
F
G
H
I
J
Pre-procedure1
None.
Procedure1
Read the freeze frame data of DTC P0AA000.
| Tester Display |
|---|
| VL-Voltage before Boosting |
| VH-Voltage after Boosting |
As freeze frame data is stored immediately before and after a DTC is stored, make sure to only read the values for the moment the DTC was stored ("0(s)").
| Result | Proceed to |
|---|---|
| Difference between "VL-Voltage before Boosting" and "VH-Voltage after Boosting" is less than 56 V. | A |
| Difference between "VL-Voltage before Boosting" and "VH-Voltage after Boosting" is 56 V or more. | B |
If VH-Voltage after Boosting is output even when an off command is being sent to the system main relay (positive side), P0AA000 is output. If the difference between the "VL-Voltage before Boosting" and the "VH-Voltage after Boosting" is large, it is determined that there is an inverter (VH sensor) malfunction.
Post-procedure1
Turn the ignition switch off.
A
B
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P056014
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| Proceed to |
|---|
| NEXT |
NEXT
Check the connection condition of the OH3 floor wire connector and the contact pressure of each terminal. Check the terminals for deformation, and check the connector for water ingress and foreign matter.
- The connector is connected securely.
- The terminals are not deformed and are connected securely.
- No water or foreign matter in the connector.
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
A
B
C
| Proceed to |
|---|
| NEXT |
NEXT
| Proceed to |
|---|
| NEXT |
NEXT
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the HV battery upper cover panel.
Procedure1
Check the connector connections and contact pressure of the relevant terminals of the O70 No. 1 traction battery device box assembly connector.
The connectors are connected securely and there are no contact pressure problems.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Install the HV battery upper cover panel.
OK
NG
| Proceed to |
|---|
| NEXT |
NEXT
Check the installation condition of the ground wire OB.
The ground wire OB is securely installed.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| Proceed to |
|---|
| NEXT |
NEXT
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the HV battery upper cover panel.
Disconnect the O70 No. 1 traction battery device box assembly connector.
Disconnect the H44 hybrid vehicle control ECU connector.
Procedure1
| *a | Front view of wire harness connector
(to Hybrid Vehicle Control ECU) |
| *b | Front view of wire harness connector
(to No. 1 Traction Battery Device Box Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(H44,O70)Location & Routingewd_type=routing;type=c,c;code=H44,O70 Click Connector(H44)Instrument Panel>Instrument Panel Wire / Speaker Wire>Hybrid Vehicle Control ECUewd_type=component;type=c;code=H44;pinno=2 Click Connector(O70)Body>Floor Wire>HV Battery Junction Block Assemblyewd_type=component;type=c;code=O70;pinno=1 |
||
| H44-2 (SMRB) - O70-1 (SMRB) | Ignition switch off | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(H44,O70)Location & Routingewd_type=routing;type=c,c;code=H44,O70 Click Connector(H44)Instrument Panel>Instrument Panel Wire / Speaker Wire>Hybrid Vehicle Control ECUewd_type=component;type=c;code=H44;pinno=2 Click Connector(O70)Body>Floor Wire>HV Battery Junction Block Assemblyewd_type=component;type=c;code=O70;pinno=1 |
||
| H44-2 (SMRB) or O70-1 (SMRB) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the H44 hybrid vehicle control ECU connector.
Reconnect the O70 No. 1 traction battery device box assembly connector.
Install the HV battery upper cover panel.
OK
NG
| Proceed to |
|---|
| NEXT |
NEXT
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the HV battery upper cover panel.
Disconnect the O70 No. 1 traction battery device box assembly connector.
Procedure1
| *a | Front view of wire harness connector
(to No. 1 Traction Battery Device Box Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(O70)Location & Routingewd_type=routing;type=c;code=O70 Click Connector(O70)Body>Floor Wire>HV Battery Junction Block Assemblyewd_type=component;type=c;code=O70;pinno=3 |
||
| O70-3 (GND) - Body ground | Ignition switch off | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the O70 No. 1 traction battery device box assembly connector.
Install the HV battery upper cover panel.
OK
NG
| Proceed to |
|---|
| NEXT |
NEXT
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the HV battery upper cover panel.
Disconnect the O70 No. 1 traction battery device box assembly connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| *a | Component without harness connected
(No. 1 Traction Battery Device Box Assembly) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(O70)Location & Routingewd_type=routing;type=c;code=O70 Click Connector(O70)Body>Floor Wire>HV Battery Junction Block Assemblyewd_type=component;type=c;code=O70;pinno=1,3 |
||
| O70-1 (SMRB) - O70-3 (GND) | -40 to 80°C (-40 to 176°F) | 19.0 to 59.0 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the O70 No. 1 traction battery device box assembly connector.
Install the HV battery upper cover panel.
OK
NG
Choose the model to be inspected.
| Result | Proceed to |
|---|---|
| for 2WD | A |
| for AWD | B |
A
B
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the HV battery upper cover panel.
Disconnect the 2 HV floor under wire connectors from the No. 1 traction battery device box assembly.
Disconnect the 2 HV battery high voltage connectors from the No. 1 traction battery device box assembly.
Insulate each disconnected high-voltage connector with insulating tape. Wrap the connector from the wire harness side to the end of the connector.
Procedure1
| *a | Component without harness connected
(No. 1 Traction Battery Device Box Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(a1,z10)Location & Routingewd_type=routing;type=c,c;code=a1,z10 Click Connector(a1)Body>HV Floor Under Wire>HV Battery Junction Block Assemblyewd_type=component;type=c;code=a1;pinno=1 Click Connector(z10)Body>other>HV Supply Battery Assembly , HV Battery Junction Block Assemblyewd_type=component;type=c;code=z10;pinno=1 |
||
| a1-1 (CBI) - z10-1 (+) | Ignition switch off | 10 kΩ or higher |
If a system main relay is stuck closed, inspect the No. 1 traction battery device box assembly without removing it from the vehicle, in order to keep the relay closed.
If the result of reading the freeze frame data is A, the No. 1 traction battery device box assembly must be replaced. Measuring resistance can determine that this is either a present or past malfunction.
If the check result is OK and the past malfunction is NG, then the malfunction can be judged as a present malfunction.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the 2 HV battery high voltage connectors.
Reconnect the 2 HV floor under wire connectors.
Install the HV battery upper cover panel.
OK
NG
| Proceed to |
|---|
| NEXT |
NEXT
| Proceed to |
|---|
| NEXT |
NEXT
Be sure to wear insulated gloves.
Pre-procedure1
Install the service plug grip.
Procedure1
Clear the DTCs.
| Proceed to |
|---|
| NEXT |
Post-procedure1
Turn the ignition switch off and wait for 2 minutes or more.
NEXT
Pre-procedure1
Turn the ignition switch to ON (READY).
Procedure1
According to the display on the GTS, read the Data List and monitor the values of "Hybrid/EV Battery Voltage" and "VL-Voltage before Boosting" for 3 minutes.
| Tester Display |
|---|
| VL-Voltage before Boosting |
| Hybrid/EV Battery Voltage |
| Result | Proceed to |
|---|---|
| Difference between "Hybrid/EV Battery Voltage" and "VL-Voltage before Boosting" is always less than 50 V. | A |
| Difference between "Hybrid/EV Battery Voltage" and "VL-Voltage before Boosting" is 50 V or more. | B |
Post-procedure1
Turn the ignition switch off.
A
B
HYBRID VEHICLE CONTROL ECU:
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID VEHICLE CONTROL ECU>REMOVAL
NO. 1 TRACTION BATTERY DEVICE BOX ASSEMBLY:
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV RELAY ASSEMBLY>REMOVAL
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the HV battery upper cover panel.
Disconnect the 2 HV floor under wire connectors from the No. 1 traction battery device box assembly.
Disconnect the 2 HV battery high voltage connectors from the No. 1 traction battery device box assembly.
Insulate each disconnected high-voltage connector with insulating tape. Wrap the connector from the wire harness side to the end of the connector.
Procedure1
| *a | Component without harness connected
(No. 1 Traction Battery Device Box Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(c1,z10)Location & Routingewd_type=routing;type=c,c;code=c1,z10 Click Connector(c1)Body>HV Battey Pack Wire>HV Battery Junction Block Assemblyewd_type=component;type=c;code=c1;pinno=1 Click Connector(z10)Body>other>HV Supply Battery Assembly , HV Battery Junction Block Assemblyewd_type=component;type=c;code=z10;pinno=1 |
||
| c1-1 (CBI) - z10-1 (+) | Ignition switch off | 10 kΩ or higher |
If a system main relay is stuck closed, inspect the No. 1 traction battery device box assembly without removing it from the vehicle, in order to keep the relay closed.
If the result of reading the freeze frame data is A, the No. 1 traction battery device box assembly must be replaced. Measuring resistance can determine that this is either a present or past malfunction.
If the check result is OK and the past malfunction is NG, then the malfunction can be judged as a present malfunction.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the 2 HV battery high voltage connectors.
Reconnect the 2 HV floor under wire connectors.
Install the HV battery upper cover panel.
OK
NG
| Proceed to |
|---|
| NEXT |
NEXT