The HV battery is composed of 48 cells (3.7 V each) in series. The battery ECU assembly monitors the voltage of each HV battery cell to detect malfunctions of the HV battery.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate | DTC Output from | Priority |
|---|---|---|---|---|---|---|---|
| P1A001C | Hybrid Battery Stack 2 Cell Voltage Detection Voltage Out of Range | An open is detected in the HV battery cell voltage detection circuits of the No. 2 HV supply stack sub-assembly.
(1 trip detection logic) |
·
No. 2 HV supply stack sub-assembly ·
Battery ECU assembly |
Comes on | Master Warning:
Comes on |
HV Battery | A |
| P301A1C | Hybrid Battery Stack 1 Cell Voltage Detection Voltage Out of Range | An open is detected in the HV battery cell voltage detection circuits of the No. 1 HV supply stack sub-assembly.
(1 trip detection logic) |
·
No. 1 HV supply stack sub-assembly ·
Battery ECU assembly |
Comes on | Master Warning:
Comes on |
HV Battery | A |
| DTC No. | Data List |
|---|---|
| P1A001C | Hybrid/EV Battery Cell 1 to 48 Voltage |
| P301A1C |
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>UTILITY
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the ignition switch off and wait for 2 minutes or more.
Turn the ignition switch to ON and wait for 10 seconds or more.
Enter the following menus: Powertrain / HV Battery / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.
Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly*
Disconnecting the low voltage connector of the HV battery
*: for AWD
To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.
After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
| *a | Without waiting for 10 minutes |
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly*. The voltage should be 0 V before beginning work.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>PRECAUTION
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly*.
*: for AWD
Make sure to insulate the high-voltage connectors and terminals of the HV battery with insulating tape after removing it.
If the HV battery stored without insulating the connectors and terminals, electric shock or fire may result.
| *a | Dealer |
| *b | Battery Collection Agent |
When disposing of an HV battery, make sure to return it through an authorized collection agent who is capable of handling it safely. If the HV battery is returned via the manufacturer specified route, it will be returned properly and in a safe manner by an authorized collection agent.
Accidents such as electric shock may result if the HV battery is disposed of improperly or abandoned. Therefore, make sure to return all HV batteries through an authorized collection agent.
Before returning the HV battery, make sure to perform a recovery inspection.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>RECOVERY INSPECTION
Before returning the HV supply stack sub-assembly, make sure to perform a recovery inspection.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY STACK>RECOVERY INSPECTION
Make a note of the output DTCs as some of them may be necessary for recovery inspection of the HV battery and HV supply stack sub-assemblies.
After removing the HV battery, keep it away from water. Exposure to water may cause the HV battery to produce heat, resulting in a fire.
After the ignition switch is turned off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY
When disconnecting and reconnecting the auxiliary battery
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART
Pre-procedure1
None.
Procedure1
Check for DTCs.
| Result | Proceed to |
|---|---|
| Only P1A001C or P301A1C for Hybrid battery system is output | A |
| P1A001C or P301A1C is output and DTCs other than the DTCs in the table below are output | B |
| P1A001C or P301A1C is output and Hybrid battery system DTCs in the table below are output | C |
| P1A001C or P301A1C is output and Hybrid control system DTCs in the table below are output | D |
| System | Relevant DTC | |
|---|---|---|
| Hybrid battery system | P060A47 | Hybrid/EV Battery Energy Control Module Monitoring Processor Watchdog / Safety MCU Failure |
| P060B49 | Hybrid/EV Battery Energy Control Module A/D Processing Internal Electronic Failure | |
| P060687 | Hybrid/EV Battery Energy Control Module Processor to Monitoring Processor Missing Message | |
| Hybrid control system | P0A1F94 | Hybrid/EV Battery Energy Control Module Unexpected Operation |
Post-procedure1
Turn the ignition switch off.
A
B
C
D
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DIAGNOSTIC TROUBLE CODE CHART
Check the DTCs that were output when the vehicle was brought to the workshop.
| Result | Proceed to |
|---|---|
| "P1A001C" is also output. | A |
| "P301A1C" is also output. | B |
A
B
Be sure to wear insulated gloves and protective goggles.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 1 HV battery hose.
Procedure1
Check the connections of the z13 battery ECU assembly connector.
The connector is connected securely and there are no contact problems.
| Result | Proceed to | |
|---|---|---|
| OK | A | |
| Not connected securely | The terminals are not damaged or corroded | B |
| Not connected securely | The terminals are damaged or corroded | C |
Post-procedure1
Install the No. 1 HV battery hose.
A
B
C
Pre-procedure1
None.
Procedure1
Read the value of freeze frame data items "Hybrid/EV Battery Cell 25 Voltage" through "Hybrid/EV Battery Cell 48 Voltage" for DTC P1A001C and make a note if the value of any is 1.6 V or less.
| Tester Display |
|---|
| Hybrid/EV Battery Cell 25 Voltage |
| Hybrid/EV Battery Cell 26 Voltage |
| Hybrid/EV Battery Cell 27 Voltage |
| Hybrid/EV Battery Cell 28 Voltage |
| Hybrid/EV Battery Cell 29 Voltage |
| Hybrid/EV Battery Cell 30 Voltage |
| Hybrid/EV Battery Cell 31 Voltage |
| Hybrid/EV Battery Cell 32 Voltage |
| Hybrid/EV Battery Cell 33 Voltage |
| Hybrid/EV Battery Cell 34 Voltage |
| Hybrid/EV Battery Cell 35 Voltage |
| Hybrid/EV Battery Cell 36 Voltage |
| Hybrid/EV Battery Cell 37 Voltage |
| Hybrid/EV Battery Cell 38 Voltage |
| Hybrid/EV Battery Cell 39 Voltage |
| Hybrid/EV Battery Cell 40 Voltage |
| Hybrid/EV Battery Cell 41 Voltage |
| Hybrid/EV Battery Cell 42 Voltage |
| Hybrid/EV Battery Cell 43 Voltage |
| Hybrid/EV Battery Cell 44 Voltage |
| Hybrid/EV Battery Cell 45 Voltage |
| Hybrid/EV Battery Cell 46 Voltage |
| Hybrid/EV Battery Cell 47 Voltage |
| Hybrid/EV Battery Cell 48 Voltage |
| Proceed to |
|---|
| NEXT |
Post-procedure1
Turn the ignition switch off.
NEXT
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>P0E2D00
| Result | Proceed to |
|---|---|
| The voltage between the terminals is 1.6 V or less. | A |
| Other than above | B |
A
B
Be sure to wear insulated gloves and protective goggles.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 1 HV battery hose.
Procedure1
Check the connections of the z15 battery ECU assembly connector.
The connector is connected securely and there are no contact problems.
| Result | Proceed to | |
|---|---|---|
| OK | A | |
| Not connected securely | The terminals are not damaged or corroded | B |
| Not connected securely | The terminals are damaged or corroded | C |
Post-procedure1
Install the No. 1 HV battery hose.
A
B
C
Pre-procedure1
None.
Procedure1
Read the value of freeze frame data items "Hybrid/EV Battery Cell 1 Voltage" through "Hybrid/EV Battery Cell 24 Voltage" for DTC P301A1C and make a note if the value of any is 1.6 V or less.
| Tester Display |
|---|
| Hybrid/EV Battery Cell 1 Voltage |
| Hybrid/EV Battery Cell 2 Voltage |
| Hybrid/EV Battery Cell 3 Voltage |
| Hybrid/EV Battery Cell 4 Voltage |
| Hybrid/EV Battery Cell 5 Voltage |
| Hybrid/EV Battery Cell 6 Voltage |
| Hybrid/EV Battery Cell 7 Voltage |
| Hybrid/EV Battery Cell 8 Voltage |
| Hybrid/EV Battery Cell 9 Voltage |
| Hybrid/EV Battery Cell 10 Voltage |
| Hybrid/EV Battery Cell 11 Voltage |
| Hybrid/EV Battery Cell 12 Voltage |
| Hybrid/EV Battery Cell 13 Voltage |
| Hybrid/EV Battery Cell 14 Voltage |
| Hybrid/EV Battery Cell 15 Voltage |
| Hybrid/EV Battery Cell 16 Voltage |
| Hybrid/EV Battery Cell 17 Voltage |
| Hybrid/EV Battery Cell 18 Voltage |
| Hybrid/EV Battery Cell 19 Voltage |
| Hybrid/EV Battery Cell 20 Voltage |
| Hybrid/EV Battery Cell 21 Voltage |
| Hybrid/EV Battery Cell 22 Voltage |
| Hybrid/EV Battery Cell 23 Voltage |
| Hybrid/EV Battery Cell 24 Voltage |
| Proceed to |
|---|
| NEXT |
Post-procedure1
Turn the ignition switch off.
NEXT
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>P0E2D00
| Result | Proceed to |
|---|---|
| The voltage between the terminals is 1.6 V or less. | A |
| Other than above | B |
A
B