The cause of this malfunction may be the low-voltage circuit.
Check whether there is an open circuit in the rear inverter +B low-voltage power source system or a problem in the communication between the front inverter and rear inverter.
| Area | Inspection |
|---|---|
| Rear inverter +B low-voltage power source system check | Check for inverter overcurrent malfunction due to +B voltage decrease (low voltage circuit) |
| Communication malfunction between MG-ECU inside hybrid motor control inverter assembly and MGR-ECU inside rear hybrid motor control inverter assembly | Check for inverter overcurrent malfunction due to communication malfunction. |
| Check for short to ground in rear inverter +B low-voltage power source system | - |
Refer to the wiring diagram for Rear Shut Down Signal Circuit.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>Rear Shut Down Signal Circuit
This diagnostic procedure is referenced to in the diagnostic procedure of several DTCs.
If the result of this diagnostic procedure is normal, proceed as directed in the procedure for the DTC.
Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly*
*: for AWD
Disconnecting the low voltage connector of the HV battery
To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.
After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
| *a | Without waiting for 10 minutes |
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly*. The voltage should be 0 V before beginning work.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly*.
*: for AWD
After the ignition switch is turned off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY
When disconnecting and reconnecting the auxiliary battery
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART
Pre-procedure1
Remove the PCU-RR fuse from the fusible link block assembly.
Procedure1
| *1 | Fusible Link Block Assembly |
| *2 | PCU-RR Fuse |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| PCU-RR fuse | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Install the PCU-RR fuse.
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
| *a | Front view of wire harness connector
(to Rear Hybrid Motor Control Inverter Assembly) |
Disconnect the rear hybrid motor control inverter assembly connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(O74)Location & Routingewd_type=routing;type=c;code=O74 Click Connector(O74)Body>Floor Wire>Rear Hybrid Motor Control Inverter Assemblyewd_type=component;type=c;code=O74;pinno=1,7 |
||
| O74-1 (GNR1) - Body ground | Ignition switch off | Below 1 Ω |
| O74-7 (GNR2) - Body ground | Ignition switch off | Below 1 Ω |
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(O74)Location & Routingewd_type=routing;type=c;code=O74 Click Connector(O74)Body>Floor Wire>Rear Hybrid Motor Control Inverter Assemblyewd_type=component;type=c;code=O74;pinno=6,13 |
||
| O74-6 (+BR1) - Body ground | Ignition switch ON | 11 to 14 V |
| O74-13 (+BR2) - Body ground | Ignition switch ON | 11 to 14 V |
Turning the ignition switch to ON with the rear hybrid motor control inverter assembly connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Turn the ignition switch off.
Disconnect the cable to the negative (-) auxiliary battery terminal.
Reconnect the rear hybrid motor control inverter assembly connector.
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the hybrid motor control inverter assembly connector.
| *a | Front view of wire harness connector
(to Hybrid Motor Control Inverter Assembly) |
| *b | Front view of wire harness connector
(to Rear Hybrid Motor Control Inverter Assembly) |
Disconnect the rear hybrid motor control inverter assembly connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A56,O74)Location & Routingewd_type=routing;type=c,c;code=A56,O74 Click Connector(A56)Engine Compartment>Engine Room Main Wire>Hybrid Motor Control Inverter Assemblyewd_type=component;type=c;code=A56;pinno=3,9,18 Click Connector(O74)Body>Floor Wire>Rear Hybrid Motor Control Inverter Assemblyewd_type=component;type=c;code=O74;pinno=2,8,4 |
||
| A56-3 (CARH) - O74-2 (CARH) | Ignition switch off | Below 1 Ω |
| A56-9 (CARL) - O74-8 (CARL) | Ignition switch off | Below 1 Ω |
| A56-18 (SDNR) - O74-4 (SDNR) | Ignition switch off | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A56,O74)Location & Routingewd_type=routing;type=c,c;code=A56,O74 Click Connector(A56)Engine Compartment>Engine Room Main Wire>Hybrid Motor Control Inverter Assemblyewd_type=component;type=c;code=A56;pinno=3,9,18 Click Connector(O74)Body>Floor Wire>Rear Hybrid Motor Control Inverter Assemblyewd_type=component;type=c;code=O74;pinno=2,8,4 |
||
| A56-3 (CARH) or O74-2 (CARH) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| A56-9 (CARL) or O74-8 (CARL) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| A56-18 (SDNR) or O74-4 (SDNR) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A56,O74)Location & Routingewd_type=routing;type=c,c;code=A56,O74 Click Connector(A56)Engine Compartment>Engine Room Main Wire>Hybrid Motor Control Inverter Assemblyewd_type=component;type=c;code=A56;pinno=3,9,18 Click Connector(O74)Body>Floor Wire>Rear Hybrid Motor Control Inverter Assemblyewd_type=component;type=c;code=O74;pinno=2,8,4 |
||
| A56-3 (CARH) or O74-2 (CARH) - Body ground | Ignition switch ON | Below 1 V |
| A56-9 (CARL) or O74-8 (CARL) - Body ground | Ignition switch ON | Below 1 V |
| A56-18 (SDNR) or O74-4 (SDNR) - Body ground | Ignition switch ON | Below 1 V |
Turning the ignition switch to ON with the hybrid motor control inverter assembly connector and ECM connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Turn the ignition switch off.
Disconnect the cable to the negative (-) auxiliary battery terminal.
Reconnect the rear hybrid motor control inverter assembly connector.
Reconnect the hybrid motor control inverter assembly connector.
OK
NG
Pre-procedure1
Check the PCU RR relay for improper installation.
The relay is installed securely.
If performing a reproduction test, turn the ignition switch to ON and gently vibrate the PCU RR relay with a finger before checking for DTCs.
| *1 | No. 5 Relay Block Assembly |
| *2 | PCU RR Relay |
Remove the PCU RR relay from the No. 5 relay block assembly.
Procedure1
| *1 | PCU RR Relay |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Auxiliary battery voltage not applied between terminals 1 and 2 | 10 kΩ or higher |
| Auxiliary battery voltage applied between terminals 1 and 2 | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Install the PCU RR relay.
OK
NG
Pre-procedure1
Disconnect the O90 fusible link block assembly connector.
Remove the PCU RR relay from the No. 5 relay block assembly.
Procedure1
Measure the resistance according to the value(s) in the table below.
| *1 | No. 5 Relay Block Assembly | *2 | PCU RR Relay Holder |
| *a | Front view of wire harness connector
(to Fusible Link Block Assembly) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(O90)Location & Routingewd_type=routing;type=c;code=O90 Click Connector(O90)Body>Floor Wire>Fusible Link Block Assemblyewd_type=component;type=c;code=O90;pinno=2 |
||
| O90-2 or 3 (PCU RR relay holder) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the O90 fusible link block assembly connector.
Install the PCU RR relay.
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
| *a | Front view of wire harness connector
(to Rear Hybrid Motor Control Inverter Assembly) |
Disconnect the rear hybrid motor control inverter assembly connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(O74)Location & Routingewd_type=routing;type=c;code=O74 Click Connector(O74)Body>Floor Wire>Rear Hybrid Motor Control Inverter Assemblyewd_type=component;type=c;code=O74;pinno=6,13 |
||
| O74-6 (+BR1) - Body ground | Ignition switch off | 10 kΩ or higher |
| O74-13 (+BR2) - Body ground | Ignition switch off | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the rear hybrid motor control inverter assembly connector.
OK
NG
| Proceed to |
|---|
| NEXT |
NEXT
| Proceed to |
|---|
| NEXT |
NEXT