When the engine is started by stop and start control, the engine stop and start ECU controls the starter assembly by activating the ST NO. 1 relay (for starter pinion operation) via voltage from terminal STA.
If overcurrent is detected in the starter relay circuit, the engine stop and start ECU stores DTC P061519 and blinks the stop and start cancel indicator.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Warning Indicate | Memory | DTC Output from | Priority | Note |
|---|---|---|---|---|---|---|---|---|
| P061519 | Starter Relay Circuit Current Above Threshold | Both of the following conditions are met for 1 second (1 trip detection logic):
·
Ignition switch ON. ·
Overcurrent to ST NO. 1 relay is detected. |
·
Wire harness or connector ·
ST NO. 1 relay ·
Engine stop and start ECU |
Blinks | DTC stored | Stop and Start | A | SAE Code: P0617 |
CONFIRMATION AFTER TROUBLESHOOTING
If the cable is disconnected from the auxiliary battery terminal, stop and start control is prohibited until refresh charge is completed.
In this case, let the vehicle idle to complete the refresh charge. The refresh charge is complete when the Data List item Status of Auxiliary Battery Charge Control changes from "Refresh Charge Mode". (Usually, idling the engine for 5 to 60 minutes with the auxiliary battery fluid temperature at 11°C (52°F) or higher, the refresh charge will be completed.)
If the GTS is not available and the Data List item Status of Auxiliary Battery Charge Control cannot be checked, charge the auxiliary battery by idling the engine for approximately 5 to 60 minutes or driving the vehicle, and then drive the vehicle and check that stop and start control operates.
If the engine is started with the hood open, the system determines that a jump start has occurred. Therefore, make sure that the hood is closed before starting the engine and driving the vehicle.
After the refresh charge completes, turn the ignition switch off, wait for at least 30 seconds, and then start the engine again. If the vehicle enters refresh charge mode again while the engine is idling, the initial refresh charge did not properly complete, so wait for the refresh charge to complete.
Allow the engine to idle for 3 minutes after it is warmed up and check that the engine idle speed is within 50 rpm of the target idle speed.
Clear the DTCs.
Start the engine and warm it up.
Drive the vehicle at 7 km/h (4 mph) or more.
When performing Confirmation Driving Pattern, obey all speed limits and traffic laws.
Stop the vehicle, move the shift lever to neutral and release the clutch pedal.
Keep the engine stopped by stop and start control for 1 second or more.
Depress the clutch pedal and start the engine.
Check that DTCs are not output.
STOP AND START SYSTEM OPERATION CHECK
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>OPERATION CHECK
Before replacing the engine stop and start ECU, read the number of starter operations and write it into a new engine stop and start ECU.
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>REGISTRATION
After replacing the engine stop and start ECU, perform learning of the external backup boost converter (eco run vehicle converter assembly).
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>REGISTRATION
After replacing the engine stop and start ECU or air conditioning amplifier assembly, reset and perform learning of the air conditioning information in the engine stop and start ECU.
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>REGISTRATION
Inspect the fuses for circuits related to this system before performing the following procedure.
Using the GTS, read the freeze frame data before troubleshooting. System condition information is recorded as freeze frame data the moment a DTC is stored. This information can be useful when troubleshooting.
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>FREEZE FRAME DATA
For wire harness and connector inspection procedures and precautions, refer to "General>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>ELECTRONIC CIRCUIT INSPECTION PROCEDURE"
DTCs for the stop and start system are not cleared even if the malfunction has been repaired. After repairing the malfunction, be sure to clear the DTCs.
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>DTC CHECK / CLEAR
Pre-procedure1
Disconnect the A66 engine stop and start ECU connector.
Remove the BBC NO. 1 fuse and BBC NO. 2 fuse from the No. 1 engine room relay block.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A66)Location & Routingewd_type=routing;type=c;code=A66 Click Connector(A66)Instrument Panel>Engine Room Main Wire>Engine Stop and Start ECUewd_type=component;type=c;code=A66;pinno=1,3 |
||
| A66-1 (BIN2) - 2 (BBC NO. 2 fuse) | Always | Below 1 Ω |
| A66-3 (BIN1) - 2 (BBC NO. 1 fuse) | Always | Below 1 Ω |
| A66-1 (BIN2) - Body ground and other terminals | Always | 10 kΩ or higher |
| A66-3 (BIN1) - Body ground and other terminals | Always | 10 kΩ or higher |
| 2 (BBC NO. 2 fuse) - Body ground and other terminals | Always | 10 kΩ or higher |
| 2 (BBC NO. 1 fuse) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None.
OK
NG
Pre-procedure1
Disconnect the H45 certification ECU (smart key ECU assembly) connector.*1
*1: w/ Entry and Start System
Disconnect the A64 clutch start switch assembly connector.
Disconnect the A54 ECM connector.
Disconnect the A66 and A67 engine stop and start ECU connectors.
Remove the ST NO. 1 relay from the No. 1 engine room relay block.
Procedure1
Measure the resistance according to the value(s) in the table below.
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>TERMINALS OF ECU
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A67,A66)Location & Routingewd_type=routing;type=c,c;code=A67,A66 Click Connector(A67)Instrument Panel>Engine Room Main Wire>Engine Stop and Start ECUewd_type=component;type=c;code=A67;pinno=21 Click Connector(A66)Instrument Panel>Engine Room Main Wire>Engine Stop and Start ECUewd_type=component;type=c;code=A66;pinno=1,3 |
||
| A67-21 (STA) - 2 (ST NO. 1 relay holder) | Always | Below 1 Ω |
| A67-21 (STA) - Body ground and other terminals | Always | 10 kΩ or higher |
| 2 (ST NO. 1 relay holder) - Body ground and other terminals | Always | 10 kΩ or higher |
| A66-1 (BIN2) - A67-21 (STA) | Always | 10 kΩ or higher |
| A66-3 (BIN1) - A67-21 (STA) | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None.
OK
NG
Pre-procedure1
Disconnect the engine stop and start ECU connector.
| *a | Component without harness connected
(Engine Stop and Start ECU) |
- | - |
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A67)Location & Routingewd_type=routing;type=c;code=A67 Click Connector(A67)Instrument Panel>Engine Room Main Wire>Engine Stop and Start ECUewd_type=component;type=c;code=A67;pinno=21,6 |
||
| A67-21 (STA) - A67-6 (DGND) | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None.
OK
NG
Inspect the ST NO. 1 relay.
Click hereEngine / Hybrid System>M15A-FKS (STARTING)>RELAY>INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING
NG