Home › Engine / Hybrid System › STOP AND START › STOP AND START SYSTEM › from 2021.07
RM3700E _51 Engine / Hybrid System _105429 STOP AND START _0482038 STOP AND START SYSTEM J

STOP AND START  STOP AND START SYSTEM  Stop and Start System does not Operate (Battery Condition)  


DESCRIPTION

When the stop and start system does not operate, check whether the operation is prohibited because the auxiliary battery conditions are not met.

HINT:
Data List items
Hood Courtesy Switch Auxiliary Battery Current Auxiliary Battery Fluid Temperature (Start) Auxiliary Battery Fluid Temperature
Idling Stop Rate Total Idling Stop Rate Integrated Current Status of Auxiliary Battery Charge Control
Minimum Voltage (Cranking) Minimum Voltage (Starter Solenoid Engagement) State of BBC Stop&Start Operating Permission (Power Management)
Stop&Start Operating Permission (Minimum Voltage (Starter Solenoid Engagement)) Stop&Start Operating Permission (Minimum Voltage (Cranking)) Stop&Start Operating Permission (Integrated Current) Stop&Start Operating Prohibition (Jump Start)
Stop&Start Operating Prohibition (Manual Start for the First Time) Auxiliary Battery Type Ambient Temperature Alternator Status
Stop&Start Operating Prohibited by Battery Low Voltage - - -


NOTICE:

If the Data List item Stop&Start Operating Permission (Power Management) is "NG" even after correcting a certain problem using the diagnostic troubleshooting procedures, the problem may be due to the auxiliary battery charge amount being temporarily low or the auxiliary battery may be deteriorated. However, there may be multiple overlapping conditions which are causing system operation to be prohibited, so make sure to always confirm all the diagnostic troubleshooting procedures.


PROCEDURE

1.CHECK MULTI-INFORMATION DISPLAY
a.

Check whether the multi-information display displayed that the specified auxiliary battery is not equipped.

HINT:

The multi-information display is displayed when the voltage decreases below the minimum voltage necessary for starting the non-specified auxiliary battery when stop and start control is operated.



Result:
Result Proceed to
No display A
Displayed in past B



A

2.CHECK DTC OUTPUT

B

15.CHECK AUXILIARY BATTERY SETTINGS AND EQUIPPED AUXILIARY BATTERY
2.CHECK DTC OUTPUT
a.

Enter the following menus.

Powertrain > Stop and Start > Trouble Codes
50001 392
Result:
Result Proceed to
DTCs are not output A
DTCs are output B




A

3.READ VALUE USING GTS (STOP&START OPERATING PERMISSION (POWER MANAGEMENT))

B

3.READ VALUE USING GTS (STOP&START OPERATING PERMISSION (POWER MANAGEMENT))
HINT:

Check whether stop and start control was prohibited based on the auxiliary battery conditions or other conditions.


a.

Enter the following menus.

Powertrain > Stop and Start > Data List
Tester Display
Stop&Start Operating Permission (Power Management)
50003 392 301

b.

According to the display on the GTS, read the Data List.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Stop&Start Operating Permission (Power Management) Permission of stop and start control based on the auxiliary battery conditions NG / OK OK: Stop and start control is permitted due to auxiliary battery condition, or Active Test (forced permission) is performed -
Result:
Result Proceed to
NG is displayed A
OK is displayed B




A

4.READ VALUE USING GTS (BATTERY TYPE)

B

END (CHECK OTHER STOP AND START CONTROL PERMISSION/PROHIBITION CONDITIONS)

4.READ VALUE USING GTS (BATTERY TYPE)
a.

Enter the following menus.

Powertrain > Stop and Start > Data List
Tester Display
Battery Type
50003 392 349

b.

Check the "Auxiliary Battery Type" Data List Item.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Battery Type Set auxiliary battery type Specified / Other Specified: Specified auxiliary battery
Other: Non-specified auxiliary battery
-

c.

Check whether the auxiliary battery is specified or not specified.


Result:
GTS Display Proceed to
Specified A
Other B



A

5.READ VALUE USING GTS (STOP&START OPERATING PROHIBITION (JUMP START))

B

15.CHECK AUXILIARY BATTERY SETTINGS AND EQUIPPED AUXILIARY BATTERY
5.READ VALUE USING GTS (STOP&START OPERATING PROHIBITION (JUMP START))
HINT:

Check whether stop and start control was prohibited based on the jump start auxiliary battery condition.


a.

Enter the following menus.

Powertrain > Stop and Start > Data List
Tester Display
Stop&Start Operating Prohibition (Jump Start)
50003 392 335

b.

According to the display on the GTS, read the Data List.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Stop&Start Operating Prohibition (Jump Start) Prohibition of stop and start control based on the jump start conditions Permit / Prohibit Permit: Except for jump start conditions When Prohibit is displayed, stop and start control will be prohibited until the ignition switch is turned off.
Jump start conditions: Engine started with the engine hood open and the ignition switch turned START

Result:
Result Proceed to
Permit is displayed A
Prohibit is displayed B


HINT:
·

A jump start is determined if the engine is started with the engine hood open.

·

After turning the ignition switch off and waiting approximately 30 seconds, a jump start is determined to have not occurred if the engine started with the engine hood closed.




A

6.READ VALUE USING GTS (STOP&START OPERATING PROHIBITION (MANUAL START FOR THE FIRST TIME))

B

18.READ VALUE USING GTS (HOOD COURTESY SWITCH)
6.READ VALUE USING GTS (STOP&START OPERATING PROHIBITION (MANUAL START FOR THE FIRST TIME))
HINT:

Check whether the stop and start control was prohibited based on the manual start auxiliary battery condition.


a.

Enter the following menus.

Powertrain > Stop and Start > Data List
Tester Display
Stop&Start Operating Prohibition (Manual Start for the First Time)
50003 392 605

b.

According to the display on the GTS, read the Data List.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Stop&Start Operating Prohibition (Manual Start for the First Time) Prohibition of stop and start control based on the manual start conditions Permit / Prohibit Permit: Except for manual start conditions
·

When Prohibit is displayed, stop and start control will be prohibited until the ignition switch is turned off.

·

During manual start conditions:

-

Clutch start switch OFF or vehicle speed signal input

-

Neutral position sensor (neutral position switch) OFF

-

Starter signal OFF



Result:
Result Proceed to
Permit is displayed A
Prohibit is displayed B




A

7.READ VALUE USING GTS (STATE OF BBC)

B

END (STOP AND START CONTROL PROHIBITED DUE TO MANUAL START OPERATION)

7.READ VALUE USING GTS (STATE OF BBC)
HINT:

Check the operation of the backup boost converter.


a.

Enter the following menus.

Powertrain > Stop and Start > Data List
Tester Display
State of BBC
50003 392 279

b.

According to the display on the GTS, read the Data List.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
State of BBC Backup boost converter status Cycle Err / Overvoltage / Overload / Normal / Low Vol / Duty Err / Stop&Start Sensor Electric Supply Low / Stop&Start CPU Malfunction / BBC Overcurrent / Stop&Start Starter Overcurrent / Stop&Start Reduced Voltage Reset Normal: Backup boost converter operating normally
·

Duty Err:

-

Abnormal duty ratio is detected.


·

Cycle Err:

-

Abnormal output voltage cycle is detected.


·

Low Vol:

-

A decrease in the voltage of the control IC power source within the backup boost converter is detected when ignition switch is turned to ON.


·

Overload:

-

Overcurrent is detected.


·

Overvoltage:

-

When the ignition switch is ON:

(1)

Overvoltage is detected at the control IC power source in the backup boost converter

(2)

Overheating is detected at the control IC power source in the backup boost converter


-

When boosting:

(1)

Malfunction is detected in the feedback circuit in the backup boost converter

(2)

Too high or low output voltage.




Result:
Result Proceed to
Normal is displayed A
Normal is not displayed B




A

8.READ VALUE USING GTS (ALTERNATOR STATUS)

B

8.READ VALUE USING GTS (ALTERNATOR STATUS)
HINT:

Check the power generation status of the generator.


a.

Enter the following menus.

Powertrain > Stop and Start > Data List
Tester Display
Alternator Status
50003 392 598

b.

According to the display on the GTS, read the Data List.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Alternator Status Generator power generation status Normal / Abnormal Normal: Generator operation normal -
Result:
Result Proceed to
Normal is displayed A
Normal is not displayed B




A

9.READ VALUE USING GTS (AUXILIARY BATTERY FLUID TEMPERATURE, IDLING STOP RATE AND TOTAL IDLING STOP RATE)

B

GO TO CHARGING SYSTEM

Click herePower Source / Network>M15A-FKS (BATTERY / CHARGING)>CHARGING SYSTEM>HOW TO PROCEED WITH TROUBLESHOOTING

HINT:

After performing an inspection or repairs, confirm that the stop and start system operates.



9.READ VALUE USING GTS (AUXILIARY BATTERY FLUID TEMPERATURE, IDLING STOP RATE AND TOTAL IDLING STOP RATE)
HINT:

Check the idling stop rate.


a.

Enter the following menus.

Powertrain > Stop and Start > Data List
Tester Display
Battery Fluid Temperature
Idling Stop Rate
Total Idling Stop Rate
50003 392 220,270,271

b.

According to the display on the GTS, read the Data List.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Battery Fluid Temperature Estimated temperature inside auxiliary battery Min.: -40°C (-40°F)
Max.: 215°C (419°F)
Changes according to actual temperature: Driving after engine warmed up -
Idling Stop Rate Rate of the idling stop time to the entire ignition switch to ON time of this trip Min.: 0%
Max.: 255%
- When 50% or less, the stop and start system is permitted to operate.
Total Idling Stop Rate Rate of the overall idling stop time to the overall ignition switch to ON time Min.: 0%
Max.: 255%
- When 40% or less, the stop and start system is permitted to operate.
Result:
Result Proceed to
Total Idling Stop Rate Idling Stop Rate
40% or less - A
- 50% or less
Other than above B




A

10.READ VALUE USING GTS (AUXILIARY BATTERY FLUID TEMPERATURE, AMBIENT TEMPERATURE)

B

END (STOP AND START PROHIBITED DUE TO IDLING STOP RATE MORE THAN THRESHOLD OR TOTAL IDLING STOP RATE MORE THAN THRESHOLD)
HINT:
·

If Idling Stop Rate is more than threshold or Total Idling Stop Rate is more than threshold, leave the vehicle with the engine running until Idling Stop Rate drops below threshold or Total Idling Stop Rate drops below threshold.

·

For details on the Idling Stop Rate and Total Idling Stop Rate thresholds, refer to System Description.

Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>SYSTEM DESCRIPTION

·

Prohibition according to the Idling Stop Rate is used to limit a high frequency of stop and start operations in order to ensure the lifespan of the auxiliary battery. Operation may be prohibited again due to the customer usage conditions.




10.READ VALUE USING GTS (AUXILIARY BATTERY FLUID TEMPERATURE, AMBIENT TEMPERATURE)
HINT:

Check the auxiliary battery fluid temperature.


a.

Enter the following menus.

Powertrain > Stop and Start > Data List
Tester Display
Battery Fluid Temperature
Ambient Temperature
50003 392 220,534

b.

According to the display on the GTS, read the Data List.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Battery Fluid Temperature Estimated temperature inside auxiliary battery Min.: -40°C (-40°F)
Max.: 215°C (419°F)
Changes according to actual temperature: Driving after engine warmed up -
Ambient Temperature Ambient temperature Min.: -40°C (-40°F)
Max.: 215°C (419°F)
Close to ambient temperature -
Result:
Result Proceed to
Both Auxiliary Battery Fluid Temperature and Ambient Temperature are suitable temperature
(Auxiliary Battery Fluid Temperature: -10°C (14°F) or higher and 70°C (158°F) or less, Ambient Temperature: -5°C (23°F) or higher)
A
Auxiliary Battery Fluid Temperature or Ambient Temperature is not suitable temperature
(Auxiliary Battery Fluid Temperature: -15°C (5°F) or less or 75°C (167°F) or higher, Ambient Temperature: -6°C (21.2°F) or less)
B


HINT:

The Auxiliary Battery Fluid Temperature hysteresis is 5°C (9°F) and the Ambient Temperature hysteresis is 1°C (1.8°F).




A

11.READ VALUE USING GTS (STATUS OF AUXILIARY BATTERY CHARGE CONTROL)

B

END (STOP AND START CONTROL PROHIBITED DUE TO ABNORMAL AUXILIARY BATTERY FLUID TEMPERATURE)
HINT:
·

If auxiliary battery fluid temperature is not a suitable temperature, leave the vehicle at ambient temperature to allow auxiliary battery fluid temperature to return to a suitable temperature.

·

Operation is prohibited due to the auxiliary battery fluid temperature to ensure engine startability and protect the auxiliary battery. This occurs due to the usage environment.




11.READ VALUE USING GTS (STATUS OF AUXILIARY BATTERY CHARGE CONTROL)
HINT:

Check whether stop and start control was prohibited based on the auxiliary battery charge control mode.


a.

Start the engine and allow it to idle.


b.

Enter the following menus.

Powertrain > Stop and Start > Data List
Tester Display
Status of Battery Charge Control
50003 392 274

c.

According to the display on the GTS, read the Data List.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Status of Battery Charge Control Auxiliary battery charge control status Charge Control Coordination Mode / Stop and Start Standalone Mode / Refresh Charge Mode / Stop and Start Restriction Mode / Temperature High/Low Mode / Abnormal Mode / Auxiliary Battery Condition Judgment Mode / Low Temperature Mode - -
Result:
Result Proceed to
"Refresh Charge Mode", "Battery Condition Judgment Mode" or "Abnormal Mode" is not displayed A
"Refresh Charge Mode" is displayed B
"Abnormal Mode" is displayed C
"Battery Condition Judgment Mode" is displayed*1 -


HINT:

*1: When "Battery Condition Judgment Mode" is displayed, wait approximately 2 minutes for the mode to change and then check the value.




A

12.READ VALUE USING GTS (STOP&START OPERATING PERMISSION (MINIMUM VOLTAGE (STARTER SOLENOID ENGAGEMENT) AND MINIMUM VOLTAGE (CRANKING))

B

END (STOP AND START CONTROL PROHIBITED IN REFRESH CHARGE MODE)
HINT:

Let the vehicle idle with the auxiliary battery fluid temperature at 11°C (52°F) or higher for 30 to 60 minutes to complete the refresh charge. (The refresh charge is complete when Status of Auxiliary Battery Charge Control changes from "Refresh Charge Mode".)

After the refresh charge completes, turn the ignition switch off, wait for at least 30 seconds, and then start the engine again. If the vehicle enters refresh charge mode again while the engine is idling, the initial refresh charge did not properly complete, so wait for the refresh charge to complete.



C

12.READ VALUE USING GTS (STOP&START OPERATING PERMISSION (MINIMUM VOLTAGE (STARTER SOLENOID ENGAGEMENT) AND MINIMUM VOLTAGE (CRANKING))
HINT:

Check whether stop and start control was prohibited based on the minimum starting voltage of the auxiliary battery condition.


a.

Enter the following menus.

Powertrain > Stop and Start > Data List
Tester Display
Stop&Start Operating Permission (Minimum Voltage (Starter Solenoid Engagement))
Stop&Start Operating Permission (Minimum Voltage (Cranking))
50003 392 310,311

b.

According to the display on the GTS, read the Data List.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Stop&Start Operating Permission (Minimum Voltage (Starter Solenoid Engagement)) Permission of stop and start control based on minimum voltage during starter solenoid engagement NG / OK OK: Minimum voltage when starter begins operation is equal to the threshold or higher If both Minimum Voltage (Starter Solenoid Engagement) condition and Minimum Voltage (Cranking) condition are OK, stop and start control is permitted.
Stop&Start Operating Permission (Minimum Voltage (Cranking)) Permission of stop and start control based on minimum voltage during cranking NG / OK OK: Minimum voltage when cranking is equal to the threshold or higher If both Minimum Voltage (Starter Solenoid Engagement) condition and Minimum Voltage (Cranking) condition are OK, stop and start control is permitted.
Result:
Result Proceed to
OK is displayed for 2 items A
OK is displayed for 1 item or none B


HINT:

The Data List item "Stop&Start Operating Permission (Minimum Voltage (Starter Solenoid Engagement)) and Stop&Start Operating Permission (Minimum Voltage (Cranking))" is judged OK or NG according to the values of the following Data List items.


Powertrain > Stop and Start > Data List
Tester Display
Minimum Voltage (Cranking)
Minimum Voltage (Starter Solenoid Engagement)
Battery Type
50003 392 276,277,349
Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Minimum Voltage (Cranking) Minimum voltage when cranking engine Min.: -327.68 V
Max.: 327.67 V
6 to 11 V Lowest auxiliary battery voltage measured after the starter starts operating.
Minimum Voltage (Starter Solenoid Engagement) Minimum voltage when starter begins operation Min.: -327.68 V
Max.: 327.67 V
6 to 11 V Minimum auxiliary battery voltage while the starter starts operating.
Battery Type Set auxiliary battery type Specified / Other Specified: Specified auxiliary battery
Other: Non-specified auxiliary battery
-
Permission Criteria (Specified Auxiliary Battery):
Tester Display Minimum Voltage (Starter Solenoid Engagement) Minimum Voltage (Cranking)
Stop&Start Operating Permission (Minimum Voltage (Starter Solenoid Engagement)) 8.2 V or higher -
Stop&Start Operating Permission (Minimum Voltage (Cranking)) - 8.2 V or higher


Permission Criteria (Non-specified Auxiliary Battery):
Tester Display Minimum Voltage (Starter Solenoid Engagement) Minimum Voltage (Cranking)
Stop&Start Operating Permission (Minimum Voltage (Starter Solenoid Engagement)) 8.92 V or higher -
Stop&Start Operating Permission (Minimum Voltage (Cranking)) - 8.92 V or higher




A

13.READ VALUE USING GTS (STOP&START OPERATING PROHIBITED BY BATTERY LOW VOLTAGE)

B

20.CHARGE OR REPLACE AUXILIARY BATTERY AFTER CHECKING AUXILIARY BATTERY STATE
13.READ VALUE USING GTS (STOP&START OPERATING PROHIBITED BY BATTERY LOW VOLTAGE)
HINT:

Check whether stop and start control is prohibited due to stop and start control being performed for a short period of time when the battery voltage was low.


a.

Enter the following menus.

Powertrain > Stop and Start > Data List
Tester Display
Stop&Start Operating Prohibited by Battery Low Voltage
50003 392 577

b.

According to the display on the GTS, read the Data List.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Stop&Start Operating Prohibited by Battery Low Voltage Prohibits stop and start control according to low auxiliary battery voltage Prohibit / Permit Permit:Except for auxiliary battery low voltage conditions -
Result:
Result Proceed to
Permit is displayed A
Prohibit is displayed B




A

14.READ VALUE USING GTS (STOP&START OPERATING PERMISSION (INTEGRATED CURRENT))

B

20.CHARGE OR REPLACE AUXILIARY BATTERY AFTER CHECKING AUXILIARY BATTERY STATE
14.READ VALUE USING GTS (STOP&START OPERATING PERMISSION (INTEGRATED CURRENT))
HINT:

Check whether stop and start control was prohibited based on the integrated current value auxiliary battery condition.


a.

Enter the following menus.

Powertrain > Stop and Start > Data List
Tester Display
Stop&Start Operating Permission (Integrated Current)
50003 392 334

b.

According to the display on the GTS, read the Data List.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Stop&Start Operating Permission (Integrated Current) Permission of stop and start control based on the integrated current value conditions NG / OK OK: Integrated current value is equal to the threshold or more The status depends on the value of "Integrated Current", and the OK/NG threshold differs according to the status of auxiliary battery charge control.
Result:
Result Proceed to
OK is displayed A
NG is displayed B




A

END (TURN ELECTRICAL LOAD OFF AS MUCH AS POSSIBLE)

B

17.READ VALUE USING GTS (INTEGRATED CURRENT)
15.CHECK AUXILIARY BATTERY SETTINGS AND EQUIPPED AUXILIARY BATTERY
a.

Enter the following menus.

Powertrain > Stop and Start > Data List
Tester Display
Battery Type
50003 392 349

b.

Check the "Auxiliary Battery Type" Data List Item.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Battery Type Set auxiliary battery type Specified / Other Specified: Specified auxiliary battery
Other: Non-specified auxiliary battery
-

c.

Check whether the auxiliary battery is specified or not specified.

Result:
Data List Auxiliary Battery Type Display Equipped Auxiliary Battery Proceed to
Other Specified auxiliary battery A
Other Non-specified auxiliary battery B




A

16.SWITCH AUXILIARY BATTERY TYPE

B

EXPLAIN TO CUSTOMER THAT STOP AND START SYSTEM IS LIMITED TO PREVENT AUXILIARY BATTERY MALFUNCTION WHEN A NON-SPECIFIED AUXILIARY BATTERY IS USED
HINT:

When switching to a specified auxiliary battery, Auxiliary Battery Type may not immediately switch to "Specified". To immediately switch it to "Specified", perform Switch Auxiliary Battery Type.

Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>REGISTRATION



16.SWITCH AUXILIARY BATTERY TYPE
a.

Enter the following menus.

Powertrain > Engine > Utility
Tester Display
Switch Battery Type
50005 372 4377

b.

Perform Switch Auxiliary Battery Type under Utility and set the Specified auxiliary battery.


c.

Enter the following menus.

Powertrain > Stop and Start > Data List
Tester Display
Battery Type
50003 392 349

d.

Check that the "Auxiliary Battery Type" Data List item is set to "Specified".

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Battery Type Set auxiliary battery type Specified / Other Specified: Specified auxiliary battery
Other: Non-specified auxiliary battery
-

Result:
Proceed to
NEXT



NEXT

END

17.READ VALUE USING GTS (INTEGRATED CURRENT)
HINT:

Judge the auxiliary battery condition based on the integrated current value.


a.

Start the engine and allow it to idle.


b.

Enter the following menus.

Powertrain > Stop and Start > Data List
Tester Display
Integrated Current
50003 392 273

c.

According to the display on the GTS, read the Data List.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Integrated Current Auxiliary battery integrated current Min.: -268434.456 Asec
Max.: 268435.4558 Asec
Differs according to the vehicle condition (charge/discharge conditions) -
HINT:

Judge whether the Data List item "Integrated Current" is OK or NG according to the following table.


Powertrain > Stop and Start > Data List
Tester Display
Battery Current
Integrated Current
Status of Battery Charge Control
50003 392 214,273,274
Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Battery Current Auxiliary battery current Min.: -125 A
Max.: 124.9961 A
- -
Integrated Current Auxiliary battery integrated current Min.: -268434.456 Asec
Max.: 268435.4558 Asec
Differs according to vehicle condition (charge/discharge conditions) -
Status of Battery Charge Control Auxiliary battery charge control status Charge Control Coordination Mode / Stop and Start Standalone Mode / Refresh Charge Mode / Stop and Start Restriction Mode / Temperature High/Low Mode / Abnormal Mode / Battery Condition Judgment Mode / Low Temperature Mode - -
Standard Integrated Current Value:
Status of Auxiliary Battery Charge Control Integrated Current Proceed to
Charge Control Coordination Mode, Stop and Start Standalone Mode and Low Temperature Mode Below -3974 A-sec A
Stop and Start Restriction Mode and Temperature High/Low Mode Below 0 A-sec B


Cause and Action to be Taken:
Result Cause Action to be Taken
A Integrated current value is limited for the stop and start control due to discharge or deterioration of the auxiliary battery Check the auxiliary battery condition and recharge the auxiliary battery
B
1.

Electrical load is excessive

2.

Auxiliary battery deterioration

3.

Refresh charging was not completed properly


1.

Turn electrical load off as much as possible

2.

CHARGE OR REPLACE AUXILIARY BATTERY AFTER CHECKING AUXILIARY BATTERY STATE (refer to procedure 20)

3.

Restart the engine after waiting 30 seconds or more after stopping the engine. If refresh charging begins once more, wait until refresh charging completes while idling.




·

Initialize* the auxiliary battery integrated current using the GTS after charging the auxiliary battery, and drive the vehicle until the stop and start control operates (approximately 5 to 40 minutes).

*: Use the GTS to perform Integrated Current Value Initialization.

Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>REGISTRATION

HINT:

If the Data List item "Integrated Current" is 0 A-sec or higher, it is not necessary to perform initialization.


·

When the auxiliary battery state sensor assembly current value is normal, recharge or replace the auxiliary battery

·

When the electrical load is large, a large amount of electrical discharge occurs. As a result, the integrated current value (auxiliary battery charge amount) tends to drop causing operation to be prohibited.



Result:
Proceed to
NEXT



NEXT

CHECKING AUXILIARY BATTERY STATE
a.

If the integrated current value does not exceed the threshold*1 even though the auxiliary battery has been replaced or charged until the auxiliary battery current decreases to 5 A or less, perform integrated current value initialization*2 and drive the vehicle for approximately 5 to 40 minutes until the stop and start system operates.

HINT:
·

*1: Refer to System Description for details on the integrated current threshold.

Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>SYSTEM DESCRIPTION

·

*2: Use the GTS to perform Integrated Current Value Initialization.

Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>REGISTRATION





18.READ VALUE USING GTS (HOOD COURTESY SWITCH)
HINT:

Check the engine hood courtesy switch (hood lock assembly).


a.

Enter the following menus.

Powertrain > Stop and Start > Data List
Tester Display
Hood Courtesy Switch
50003 392 207

b.

According to the display on the GTS, read the Data List.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Hood Courtesy Switch Hood courtesy switch signal ON / OFF ON: Engine hood closed
OFF: Engine hood open
The stop and start system is permitted to operate 3 seconds after the engine hood is closed.
Result:
Result Proceed to
When engine hood condition changes from open to closed, Data List switches from OFF to ON A
When engine hood condition changes from open to closed, Data List remains OFF B


HINT:

If the result is OK, the engine may have been started with the engine hood open to perform a jump start. Close the engine hood and start the engine again.




A

19.READ VALUE USING GTS (STOP&START OPERATING PROHIBITION (JUMP START))

B

GO TO ENGINE HOOD COURTESY SWITCH CIRCUIT (OPERATION PROHIBITED AS ENGINE HOOD STATE DOES NOT CHANGE TO CLOSE)

19.READ VALUE USING GTS (STOP&START OPERATING PROHIBITION (JUMP START))
a.

Check that the engine hood is closed.


b.

Turn the ignition switch off and wait for 30 seconds or more.


c.

Enter the following menus.

Powertrain > Stop and Start > Data List
Tester Display
Stop&Start Operating Prohibition (Jump Start)
50003 392 335

d.

Check that the Data List item "Stop&Start Operating Prohibition (Jump Start)" displays "Permit".

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Stop&Start Operating Prohibition (Jump Start) Prohibition of stop and start control based on the jump start conditions Permit / Prohibit Permit: Except for jump start conditions When Prohibit is displayed, stop and start control will be prohibited until the ignition switch is turned off.
Jump start conditions: Engine started with the engine hood open and the ignition switch turned START
Result:
Proceed to
NEXT


HINT:
·

Stop and start control may be prohibited if the engine was started with the engine hood open.

·

Close the engine hood and start the engine again.





NEXT

END

20.CHARGE OR REPLACE AUXILIARY BATTERY AFTER CHECKING AUXILIARY BATTERY STATE
a.

Check the auxiliary battery.

Click herePower Source / Network>M15A-FKS (BATTERY / CHARGING)>CHARGING SYSTEM>ON-VEHICLE INSPECTION

HINT:
·

Charge or replace the auxiliary battery according to the check result.

·

When the cable is disconnected from the auxiliary battery terminal or the charging control system is checked (ECM connector is disconnected), do not perform this procedure, as there is a high possibility that the system may enter refresh charge mode and operation may be prohibited.





c.

Start the engine.


d.

Enter the following menus.

Powertrain > Stop and Start > Data List
Tester Display
Battery Current
50003 392 214

e.

According to the display on the GTS, read the Data List.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Battery Current Auxiliary battery current Min.: -125 A
Max.: 124.9961 A
Differs according to vehicle condition (charge/discharge conditions) -

f.

While idling, illuminate the headlights (Lo).

HINT:

The headlights (Lo) are illuminated so that charging control is prohibited, which sets the voltage to a fixed value.



g.

Charge the auxiliary battery for approximately 5 minutes after Auxiliary battery Current drops to 5 A or less.

HINT:

The Data List item Auxiliary battery Current decreases when the battery is charged. If the auxiliary battery is charged for 5 minutes after Auxiliary battery Current drops to 5 A or less, it can be determined that the auxiliary battery is sufficiently charged.



h.

Turn off the headlights.


i.

Turn the ignition switch off and wait for 30 seconds or more.


j.

Start the engine and check the following Data List items.

Powertrain > Stop and Start > Data List
Tester Display
Minimum Voltage (Cranking)
Minimum Voltage (Starter Solenoid Engagement)
Stop&Start Operating Permission (Minimum Voltage (Starter Solenoid Engagement))
Stop&Start Operating Permission (Minimum Voltage (Cranking))
50003 392 276,277,310,311
Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Minimum Voltage (Cranking) Minimum voltage when cranking engine Min.: -327.68 V
Max.: 327.67 V
6 to 11 V Lowest auxiliary battery voltage measured after the starter starts operating.
Minimum Voltage (Starter Solenoid Engagement) Minimum voltage when starter begins operation Min.: -327.68 V
Max.: 327.67 V
6 to 11 V Minimum auxiliary battery voltage while the starter starts operating.
Stop&Start Operating Permission (Minimum Voltage (Starter Solenoid Engagement)) Permission of stop and start control based on minimum voltage during starter solenoid engagement NG / OK OK: Minimum voltage when starter begins operation is equal to the threshold or higher If both Minimum Voltage (Starter Solenoid Engagement) condition and Minimum Voltage (Cranking) condition are OK, stop and start control is permitted.
Stop&Start Operating Permission (Minimum Voltage (Cranking)) Permission of stop and start control based on minimum voltage during cranking NG / OK OK: Minimum voltage when cranking is equal to the threshold or higher If both Minimum Voltage (Starter Solenoid Engagement) condition and Minimum Voltage (Cranking) condition are OK, stop and start control is permitted.
Permission Criteria (Specified Auxiliary Battery):
Tester Display Minimum Voltage (Starter Solenoid Engagement) Minimum Voltage (Cranking)
Stop&Start Operating Permission (Minimum Voltage (Starter Solenoid Engagement)) 8.2 V or higher -
Stop&Start Operating Permission (Minimum Voltage (Cranking)) - 8.2 V or higher


Permission Criteria (Non-specified Auxiliary Battery):
Tester Display Minimum Voltage (Starter Solenoid Engagement) Minimum Voltage (Cranking)
Stop&Start Operating Permission (Minimum Voltage (Starter Solenoid Engagement)) 8.92 V or higher -
Stop&Start Operating Permission (Minimum Voltage (Cranking)) - 8.92 V or higher



k.

Replace the auxiliary battery in the following situations.

·

Stop&Start Operating Permission (Minimum Voltage (Starter Solenoid Engagement), Minimum Voltage(Cranking)) are not OK.

·

Stop&Start Operating Permission (Minimum Voltage Starter Solenoid Engagement), Minimum Voltage (Cranking)) are OK, but Minimum Voltage (Starter Solenoid Engagement) and Minimum Voltage(Cranking) values are close to permission criteria.



Result:
Proceed to
NEXT



NEXT

CHECKING AUXILIARY BATTERY STATE
a.

If the integrated current value does not exceed the threshold*1 even though the auxiliary battery has been replaced or charged until the auxiliary battery current decreases to 5 A or less, perform integrated current value initialization*2 and drive the vehicle for approximately 5 to 40 minutes until the stop and start system operates.

HINT:
·

*1: Refer to System Description for details on the integrated current threshold.

Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>SYSTEM DESCRIPTION

·

*2: Use the GTS to perform Integrated Current Value Initialization.

Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>REGISTRATION