Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › ELECTRIC VEHICLE CONVERTER › 2020.08–2021.07
RM3700E _51 Engine / Hybrid System _093506 HYBRID / BATTERY CONTROL _0510646 ELECTRIC VEHICLE CONVERTER A

HYBRID / BATTERY CONTROL  ELECTRIC VEHICLE CONVERTER  REMOVAL  


CAUTION / NOTICE / HINT

COMPONENTS (REMOVAL)
A504595N01
4.646,1.719 5.063,1.719 false 3.979,0.781 4.396,0.781 false 1.74,1.625 2.156,1.625 false 5.063,3.125 5.479,3.125 false 6.448,0.177 6.865,0.177 false 5.198,1.583 5.479,1.938 0.281,0.354 18 false 1 4.5,0.635 4.781,0.99 0.281,0.354 18 false 2 5.573,2.979 5.854,3.333 0.281,0.354 18 false 2 1.552,1.469 1.833,1.823 0.281,0.354 18 false 2 5.979,0.052 6.635,0.417 0.656,0.365 18 false 3, 4

Procedure Part Name Code
Z101186

Z101188

Z101187

1 HYBRID MOTOR CONTROL INVERTER ASSEMBLY G92A0 - - -
2 WIRE HARNESS CLAMP BRACKET - - - -
3 VERIFY THAT VOLTAGE OF INVERTER WITH CONVERTER IS 0 V - (Click here) - -
4 CLEAN HYBRID MOTOR CONTROL INVERTER ASSEMBLY G92A0 (Click here) - -

A504596N01
3.646,1.938 3.979,1.938 false 4.177,3.271 4.51,3.271 false 2.938,3.719 3.271,3.719 false 4.844,4.49 5.177,4.49 false 2.635,4.281 3.146,4.281 false 2.521,3.031 2.938,3.031 false 6.417,0.281 6.75,0.281 false 6.427,0.75 6.76,0.75 false 4.094,1.875 4.708,2.073 0.615,0.198 10 false ● *1 2.094,2.938 2.604,3.417 0.51,0.479 10 false ● 2.156,4.188 2.698,4.708 0.542,0.521 10 false ● 5.25,4.417 5.594,4.646 0.344,0.229 10 false ● 4.635,3.219 4.979,3.448 0.344,0.229 10 false ● 2.75,3.635 3.094,3.865 0.344,0.229 10 false ● 6.01,0.146 6.573,0.667 0.563,0.521 18 false 5, 8 6.167,0.604 6.729,1.125 0.563,0.521 18 false 6 2.375,4.115 2.938,4.635 0.563,0.521 18 false 7 2.313,2.875 2.875,3.396 0.563,0.521 18 false 9 4.219,3.302 4.833,3.5 0.615,0.198 10 false x8 3.406,3.677 4.021,3.875 0.615,0.198 10 false x3 4.865,4.542 5.479,4.74 0.615,0.198 10 false x8

Procedure Part Name Code
Z101186

Z101188

Z101187

5 HOW TO PREVENT STATIC ELECTRICITY - (Click here) - -
6 DRAIN COOLANT (for Inverter) - - (Click here) -
7 CONVERTER COVER - (Click here) - -
8 SEAL PACKING FROM HYBRID MOTOR CONTROL INVERTER ASSEMBLY - (Click here) - -
9 HV CONVERTER KIT - (Click here) - -

CAUTION / NOTICE / HINT

The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed and installed, or replaced during HV converter kit removal/installation are shown below.

Necessary Procedures After Parts Removed/Installed/Replaced
Replaced Part or Performed Procedure Necessary Procedures Effect/Inoperative Function when Necessary Procedure not Performed Link
Auxiliary battery terminal is disconnected/reconnected Memorize steering angle neutral point Parking assist monitor system (Click here)
Panoramic view monitor system (Click here)

CAUTION:
·
A340386

Orange wire harnesses and connectors indicate high-voltage circuits. To prevent electric shock, always follow the procedure described in the repair manual.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION

·
A340358

To prevent electric shock, wear insulated gloves when working on wire harnesses and components of the high voltage system.



NOTICE:
A309734

·

If metal shavings are created when bolts are removed from the hybrid motor control inverter assembly, remove them using tape or equivalent.

·

Use non-residue type tape.



HINT:

When the cable is disconnected / reconnected to the auxiliary battery terminal, systems temporarily stop operating. However, each system has a function that completes learning the first time the system is used.

·

Learning completes when vehicle is driven

Effect/Inoperative Function When Necessary Procedures are not Performed Necessary Procedures Link
Lane tracing assist system Drive the vehicle straight ahead at 35 km/h (22 mph) or more for 5 seconds or more. (Click here)
Pre-collision system
Parking support brake system

·

Learning completes when vehicle is operated normally

Effect/Inoperative Function When Necessary Procedures are not Performed Necessary Procedures Link
Power door lock control system
·

Back door opener


Perform door unlock operation with door control switch or electrical key transmitter sub-assembly switch. (Click here)
Power back door system Fully close the back door by hand.
HINT:

Initialization is not necessary if the above procedures are performed while the back door is closed.


(Click here)
Air conditioning system After the ignition switch is turned to ON, the servo motor standard position is recognized. -



PROCEDURE

Hide G92A0 1.REMOVE HYBRID MOTOR CONTROL INVERTER ASSEMBLY

Hide 3. VERIFY THAT VOLTAGE OF HYBRID MOTOR CONTROL INVERTER ASSEMBLY IS 0 V

CAUTION:

Wear insulating gloves.


NOTICE:

Do not allow any foreign matter or water to enter the hybrid motor control inverter assembly.


a.
A504552C03
3.958,0.875 4.583,0.24 true 2.042,0.104 2.323,0.458 0.281,0.354 18 false i 4.635,0.125 4.917,0.479 0.281,0.354 10 false *a
*a Tape - -


i.

Remove the protective tape from the HV floor under wire opening.



b.
A502572C03
4.229,0.417 4.74,0.417 true 5.01,0.406 5.74,0.406 true 0.552,0.083 0.833,0.438 0.281,0.354 18 false i 4.01,0.344 4.292,0.698 0.281,0.354 10 false *a 5.802,0.323 6.083,0.677 0.281,0.354 10 false *a
*a Voltage Measurement Position - -


i.

Using a voltmeter, measure the voltage between the high voltage cable connector terminals.

Standard voltage:

0V


HINT:
·

Use measuring range of DC 750 V or more on the voltmeter.

·

If it is confirmed that high-voltage is not being applied to the hybrid motor control inverter assembly, the following procedures can be performed without using insulated tools or gloves.





c.
A502573N04
1.896,0.073 2.177,0.427 0.281,0.354 18 false i

i.

Apply protective tape to the area that was exposed.

NOTICE:

Use non-residue type tape.




Hide G92A0 4.CLEAN HYBRID MOTOR CONTROL INVERTER ASSEMBLY

Z101186

NOTICE:

To prevent foreign matter from entering the hybrid motor control inverter assembly, make sure that the protective tape is not partially removed.



a.
A502574N02
1.885,0.063 2.167,0.417 0.281,0.354 18 false i

i.

Using a piece of cloth, clean the outside of the hybrid motor control inverter assembly and around the bolts.



Hide 5. HOW TO PREVENT STATIC ELECTRICITY

Z101186

NOTICE:
·

Static electricity should be eliminated when removing/installing the hybrid motor control inverter assembly.

·

Do not touch the electronic components of a circuit board.

·

Keep clothes away from electronic components.

·

Place the hybrid motor control inverter assembly and any removed electronic components on SST (antistatic mat).




a.
A468986N01
3.01,0.385 2.677,0.281 2.677,0.281 3.917,0.104 true 0.427,0.125 1.719,0.531 1.292,0.406 18 false i, ii, iii, iv, v 2.406,0.229 2.865,0.427 0.458,0.198 10 false SST

i.

Wear an antistatic wrist strap.

SST
09890-47010  


ii.

Connect the ground clip of the antistatic mat securely to a ground point provided in the workshop or on a workbench (anchor bolt).

SST
09890-47010  

HINT:

If the ground clip cable is too short, use an extension cable.



iii.

Connect the ground clip of the antistatic wrist strap securely to the specified point of the antistatic mat.


iv.

When handling internal components of the hybrid motor control inverter assembly, use only antistatic gloves or bare hands to prevent damage from static electricity or the entry of foreign matter.



Hide 6.DRAIN COOLANT (for Inverter)

a.
A504597N01
4.292,0.083 4.573,0.438 0.281,0.354 18 false iii 0.5,0.104 0.781,0.458 0.281,0.354 18 false i 3.063,0.51 3.344,0.865 0.281,0.354 18 false ii

i.

Place the hybrid motor control inverter assembly on a stand as shown in the illustration.

NOTICE:
·

Make sure to use the stand, otherwise the low voltage connectors or inverter upper cover may be damaged.

·

Make sure to place the hybrid motor control inverter assembly on the stand so that the coolant pipes are positioned downward.




ii.

Connect the ground clip of the antistatic wrist strap securely to the hybrid motor control inverter assembly.


iii.

Remove the 2 caps from the coolant pipes and drain the coolant (for inverter).



b.
A505406N01
0.469,0.104 0.75,0.458 0.281,0.354 18 false i 4.083,0.104 4.365,0.458 0.281,0.354 18 false ii

i.

Blow compressed air into the hybrid motor control inverter assembly until most all of the coolant (for inverter) is blown out.

NOTICE:
·

Do not damage the coolant pipes.

·

Apply compressed air to the silver colored coolant pipe.



HINT:
·

Use a piece of cloth as shown in the illustration to prevent the coolant (for inverter) from spraying.

·

Cover the air inlet port with a piece of cloth to minimize air leakage.




ii.

Install the 2 caps to the coolant pipes.



Hide 7.REMOVE CONVERTER COVER

a.
A505407N01
2.229,0.073 2.51,0.427 0.281,0.354 18 false i

i.

Remove the 8 bolts.



b.
A501090C01
5.125,1.01 5.854,1.26 5.854,1.26 6.542,1.021 true 0.469,0.833 0.677,1.083 false 5.198,3.083 5.521,3.396 true 5.76,1.302 5.938,1.458 0.177,0.156 10 true *a 0.281,0.75 0.458,0.906 0.177,0.156 10 true *a 5.563,3.333 5.74,3.49 0.177,0.156 10 true *a 2.354,2.906 2.667,3.104 0.313,0.198 10 false OK 2.156,2.115 2.375,2.281 0.219,0.167 10 true NG

i.

Using a screwdriver with its tip wrapped with protective tape, remove the converter cover from the hybrid motor control inverter assembly.

NOTICE:
·

Do not damage the sealing surfaces of the hybrid motor control inverter assembly.

·

Do not touch or allow grease or oil to contact the sealing surfaces of the hybrid motor control inverter assembly.

·

Be careful not to damage the sealing surfaces of the hybrid motor control inverter assembly.

·

To prevent internal components of the hybrid motor control inverter assembly from being damaged, do not insert the screwdriver excessively.





Hide 8.REMOVE SEAL PACKING FROM INVERTER WITH CONVERTER ASSEMBLY

Z101186

NOTICE:
·

Do not allow any removed seal packing to enter the hybrid motor control inverter assembly.

·

Do not touch the circuit board.

·

Do not allow any moisture to come into contact.




a.
A504553C02
1.49,0.24 1.771,0.469 true 2.208,2.083 2.594,2.51 true 2.521,1.01 2.813,1.01 true 1.104,1.521 1.396,1.521 true 1.281,0.115 1.594,0.313 0.313,0.198 10 false *a 0.917,1.417 1.229,1.615 0.313,0.198 10 false *a 2.833,0.906 3.146,1.104 0.313,0.198 10 false *a 2.615,2.438 2.875,2.594 0.26,0.156 10 false *a 0.396,0.042 1.031,0.344 0.635,0.302 18 false i, ii, iii
*a Tape - -


i.

Using a finger, remove any seal packing that has seeped into the hybrid motor control inverter assembly.

HINT:

Make sure to remove any seal packing which has seeped toward the inside of hybrid motor control inverter assembly before installing the seal packing removal cover, otherwise the seal packing may be pushed into the hybrid motor control inverter assembly.



ii.

Break off the seal packing removal cover and scraper at each break off line.


iii.

Set the seal packing removal cover on the hybrid motor control inverter assembly and secure it with tape.

NOTICE:

Make sure that the seal packing removal cover is in secure contact with the inside surface of the hybrid motor control inverter assembly without any gaps.




b.
A504554C03
2.99,0.188 3.479,0.521 true 2.802,0.052 3.115,0.25 0.313,0.198 10 false *a 2.031,0.063 2.75,0.354 0.719,0.292 18 false i, ii, iii
*a MG Connector Opening - -


i.

Place the hybrid motor control inverter assembly on its side on an antistatic mat as shown in the illustration.

NOTICE:
·

Make sure that the MG connector opening in the hybrid motor control inverter assembly is facing upward.

·

Make sure that the hybrid motor control inverter assembly is oriented correctly, otherwise seal packing may enter the hybrid motor control inverter assembly.




ii.

Using a scraper, remove any remaining seal packing from the hybrid motor control inverter assembly.

NOTICE:
·

It is not necessary to remove small amounts of seal packing which are not easily scraped off.

A393901C01
2.24,0.958 2.479,0.76 2.479,0.76 2.844,0.76 true 4.5,0.938 4.74,0.74 4.74,0.74 5.146,0.74 true 4.375,1.365 4.615,1.167 4.615,1.167 4.979,1.167 true 1.865,0.083 2.094,0.24 0.229,0.156 10 false *a 4.167,0.083 4.396,0.24 0.229,0.156 10 false *b 2.115,1.542 2.344,1.698 0.229,0.156 10 false *c 4.448,1.563 4.677,1.719 0.229,0.156 10 false *c 2.906,0.688 3.219,0.885 0.313,0.198 10 false *d 5.198,0.656 5.51,0.854 0.313,0.198 10 false *e 5.021,1.083 5.333,1.281 0.313,0.198 10 false *f
*a Correct *b Incorrect
*c Width of Sealing Surface *d Difficult to Remove Seal Packing
*e Peeled Off Seal Packing *f Seal Packing Remaining on Full Width of Sealing Surface


·
A396292

Make sure to use the scraper supplied with the seal packing removal cover.



HINT:

Use the small end of the scraper to remove seal packing from small areas such as bolt holes.



iii.

Remove the tape used to secure the seal packing removal cover and then remove any seal packing which was under the tape.


iv.

Using a clean piece of cloth, clean the sealing surfaces of the hybrid motor control inverter assembly.

NOTICE:
·

Do not use compressed air or a vacuum cleaner to clean the sealing surfaces of the hybrid motor control inverter assembly.

·

Do not use non-residue solvent to clean the sealing surfaces of the hybrid motor control inverter assembly.





c.
A504555N02
2.052,0.073 2.625,0.344 0.573,0.271 18 false i, ii

i.

Remove the seal packing removal cover.

NOTICE:

Make sure that the hybrid motor control inverter assembly is oriented correctly, otherwise seal packing may enter the hybrid motor control inverter assembly when removing the seal packing removal cover.



ii.

Make sure that the hybrid motor control inverter assembly is free of foreign matter.



Hide 9.REMOVE HV CONVERTER KIT

Z101186

NOTICE:
·

Do not touch the circuit board.

·

Do not allow any foreign matter or water to enter the hybrid motor control inverter assembly.




a.
A504556N02
2.063,0.073 2.344,0.427 0.281,0.354 18 false i

i.

Place the hybrid motor control inverter assembly on a stand as shown in the illustration.

NOTICE:

Make sure that the hybrid motor control inverter assembly is oriented correctly.




b.
A504557C02
3.271,0 3.417,0.177 0.146,0.177 10 true 1 3.854,0.042 4.01,0.24 0.156,0.198 10 true 2 3.688,2.313 3.844,2.51 0.156,0.198 10 true 3 2.073,0.063 2.5,0.365 0.427,0.302 18 false i, ii
V100135

Bolt (A)
V100136

Bolt (B)


i.

Remove the 3 bolts (A) in the order shown in the illustration.


ii.

Remove the 8 bolts (B).



c.
A504558N02
1.917,0.031 2.198,0.385 0.281,0.354 18 false i

i.

Disconnect the HV converter kit connector and set it as shown in the illustration.

NOTICE:

Make sure that the wire harness of the connector is engaged to the filter condenser.




d.
A504559N02
2.271,0.042 2.552,0.396 0.281,0.354 18 false i

i.

Install 2 HV converter kit installation bolts at the positions shown in the illustration and tighten them in several steps to separate the HV converter kit from the hybrid motor control inverter assembly.

NOTICE:
·

Tighten the 2 bolts in several steps.

·

Do not forcibly separate the HV converter kit.

·

In order to prevent any foreign matter from entering the hybrid motor control inverter assembly, do not remove the bolts.





e.
A505408C01
2.281,2.667 2.552,2.427 2.552,2.427 2.729,2.427 true 2.292,3.115 2.563,2.875 2.563,2.875 2.74,2.875 true 0.969,2.208 1.146,2.208 1.146,2.208 1.646,2.042 true 4.354,2.177 4.677,2.177 true 5.771,1.24 6.094,1.24 true 5.865,2.302 6.188,2.302 true 0.74,2.781 0.917,2.781 0.917,2.781 1.417,2.615 true 0.75,3.135 0.927,3.135 0.927,3.135 1.427,2.969 true 0.771,2.135 1.083,2.333 0.313,0.198 10 false *a 2.802,2.365 3.115,2.563 0.313,0.198 10 false *a 2.813,2.813 3.125,3.01 0.313,0.198 10 false *a 0.552,2.719 0.865,2.917 0.313,0.198 10 false *a 0.563,3.073 0.875,3.271 0.313,0.198 10 false *a 6.156,1.177 6.469,1.375 0.313,0.198 10 false *b 6.24,2.25 6.552,2.448 0.313,0.198 10 false *b 4.156,2.083 4.469,2.281 0.313,0.198 10 false *b 0.531,0.156 0.771,0.521 0.24,0.365 18 false i
*a Do Not Allow Coolant (for Inverter) to Enter *b Hold Here
V100135

Remove in this Direction - -


i.

Hold the corners of the HV converter kit and remove it as shown in the illustration.

CAUTION:
·

As there is a coolant passage underneath the HV converter kit, be careful not to spill any coolant (for inverter) into the filter condenser or the holes around the edge of the hybrid motor control inverter assembly.

·

If any coolant (for inverter) spills into the filter condenser or the holes around the edge of the hybrid motor control inverter assembly, do not reuse the hybrid motor control inverter assembly.

·

If any coolant (for inverter) spills onto any area other than the specified areas, remove it with a clean piece of cloth.





f.
A504560C02
3.208,1.219 2.865,0.583 2.865,0.583 3.823,1.208 true 3.51,2.448 4.323,2.896 4.323,2.896 4.042,2.427 true 2.719,1.896 3.115,1.896 true 3.208,2.385 3.51,2.083 true 4.083,2.042 4.479,2.042 true 2.729,2.323 3.125,2.323 true 4.083,1.604 4.479,1.604 true 3.792,1.615 4.031,1.531 true 2.531,2.198 2.844,2.396 0.313,0.198 10 false *a 4.5,1.479 4.813,1.677 0.313,0.198 10 false *a 4.635,2.115 4.948,2.313 0.313,0.198 10 false *b 4.333,2.813 4.646,3.01 0.313,0.198 10 false *b 3.531,1.99 3.698,2.156 0.167,0.167 10 true *b 2.667,0.448 2.979,0.646 0.313,0.198 10 false *b 2.521,1.792 2.833,1.99 0.313,0.198 10 false *b 2,0.063 2.281,0.417 0.281,0.354 18 false i 3.594,1.521 3.76,1.688 0.167,0.167 10 true *b
*a Bolt Contacting Surface *b Bolt Hole


i.

Remove any metal shavings from the areas around the bolt holes and 2 positions where bolts were installed to separate the HV converter kit, using tape or equivalent.



g.
A504561C02
2.479,0.042 2.906,0.313 0.427,0.271 18 false i, ii
V100135

Remove in this Direction - -


i.

Using a clean scraper, lift the O-ring at the position shown in the illustration and then remove it.

CAUTION:
·

When removing the O-ring, be careful not to spill any coolant (for inverter) into the filter condenser or the holes around the edge of the hybrid motor control inverter assembly.

·

If any coolant (for inverter) spills into the filter condenser or the holes around the edge of the hybrid motor control inverter assembly, do not reuse the hybrid motor control inverter assembly.

·

If any coolant (for inverter) spills onto any area other than the filter condenser or the holes around the edge of the hybrid motor control inverter assembly, remove it with a clean piece of cloth.




ii.

Clean the O-ring groove of the hybrid motor control inverter assembly.

NOTICE:

Make sure that the O-ring groove and coolant passage of the hybrid motor control inverter assembly are free of foreign matter.